OBJECTIVES: To evaluate the efficacy and safety of the AdVance XP® sling (Boston Scientific, formerly American Medical Systems) in male stress urinary incontinence (SUI) after radical prostatectomy in a prospective multicentre study, as in recent years several studies have shown the effectiveness and safety of the AdVance sling for treating male SUI and in 2010 the second-generation AdVance XP was introduced with several changes in the sling design and a new needle shape. PATIENTS AND METHODS: In all, 115 patients were included. Patients with nocturnal UI, previous UI surgery, previous radiotherapy and a coaptive zone of <1 cm in the preoperative repositioning test were excluded. Postoperatively, a standardised 24-h pad test, quality-of-life scores [International Quality of Life score (IQOL) and International Consultation on Incontinence Questionnaire short form (ICIQ-UI SF)], visual analogue scale (VAS) for pain, five-item version of the International Index of Erectile Function (IIEF-5), International Prostate Symptom Score (IPSS) and Patient Global Impression of Improvement (PGI-I) score, were performed. All patients with a 0-5 g pad test were defined as cured and improved with a reduction of urine loss of >50%. All others were classified as failures. Significance analysis was performed using the Wilcoxon test. RESULTS: The mean (median) preoperative urine loss in the 24-h pad test was 272.0 (272.0) g. After a follow-up of 3 months (114 patients), 64.9% of the patients were cured and 31.6% had an improved continence status. The mean urine loss decreased significantly to 34.9 g (P < 0.001), with a mean VAS score of 0.5, and mean PGI-I of 1.5. After a follow-up of 24 months (80 patients), 68.8% of the patients were cured and 22.5% had improved. The mean urine loss decreased significantly to 19.1 g (P < 0.001), with a mean VAS score of 0.3, and mean PGI-I of 1.5. After a follow-up of 36 months (47 patients), 66.0% of the patients were cured and 23.4% had improved. The mean urine loss decreased significantly to 21.8 g (P < 0.001), with a mean VAS score of 0.0, and mean PGI-I of 1.6. The mean IQOL and ICIQ-UI SF improved significantly (both P < 0.001) after 36 months. There were no significant postoperative changes in IIEF-5 and IPSS. No intraoperative and no long-term complications occurred. No erosion or explanations occurred. CONCLUSION: The AdVance XP shows good and stable effectiveness and low complication rates even at a mid-term follow-up of up to 36 months.
OBJECTIVES: To evaluate the efficacy and safety of the AdVance XP® sling (Boston Scientific, formerly American Medical Systems) in male stress urinary incontinence (SUI) after radical prostatectomy in a prospective multicentre study, as in recent years several studies have shown the effectiveness and safety of the AdVance sling for treating male SUI and in 2010 the second-generation AdVance XP was introduced with several changes in the sling design and a new needle shape. PATIENTS AND METHODS: In all, 115 patients were included. Patients with nocturnal UI, previous UI surgery, previous radiotherapy and a coaptive zone of <1 cm in the preoperative repositioning test were excluded. Postoperatively, a standardised 24-h pad test, quality-of-life scores [International Quality of Life score (IQOL) and International Consultation on Incontinence Questionnaire short form (ICIQ-UI SF)], visual analogue scale (VAS) for pain, five-item version of the International Index of Erectile Function (IIEF-5), International Prostate Symptom Score (IPSS) and Patient Global Impression of Improvement (PGI-I) score, were performed. All patients with a 0-5 g pad test were defined as cured and improved with a reduction of urine loss of >50%. All others were classified as failures. Significance analysis was performed using the Wilcoxon test. RESULTS: The mean (median) preoperative urine loss in the 24-h pad test was 272.0 (272.0) g. After a follow-up of 3 months (114 patients), 64.9% of the patients were cured and 31.6% had an improved continence status. The mean urine loss decreased significantly to 34.9 g (P < 0.001), with a mean VAS score of 0.5, and mean PGI-I of 1.5. After a follow-up of 24 months (80 patients), 68.8% of the patients were cured and 22.5% had improved. The mean urine loss decreased significantly to 19.1 g (P < 0.001), with a mean VAS score of 0.3, and mean PGI-I of 1.5. After a follow-up of 36 months (47 patients), 66.0% of the patients were cured and 23.4% had improved. The mean urine loss decreased significantly to 21.8 g (P < 0.001), with a mean VAS score of 0.0, and mean PGI-I of 1.6. The mean IQOL and ICIQ-UI SF improved significantly (both P < 0.001) after 36 months. There were no significant postoperative changes in IIEF-5 and IPSS. No intraoperative and no long-term complications occurred. No erosion or explanations occurred. CONCLUSION: The AdVance XP shows good and stable effectiveness and low complication rates even at a mid-term follow-up of up to 36 months.
Authors: Stefano Salciccia; Pietro Viscuso; Giulio Bevilacqua; Antonio Tufano; Paolo Casale; Ettore De Berardinis; Giovanni Battista Di Pierro; Susanna Cattarino; Alessandro Gentilucci; Francesca Lourdes Lia; Di Giulio Ivan; Davide Rosati; Francesco Del Giudice; Alessandro Sciarra; Gianna Mariotti Journal: Adv Urol Date: 2022-06-21
Authors: Hanson Zhao; Colby P Souders; Paige K Kuhlmann; Kai Dallas; Karyn Eilber; Jennifer T Anger Journal: Int Neurourol J Date: 2021-05-05 Impact factor: 2.835
Authors: Lindsay A Hampson; Anne M Suskind; Benjamin N Breyer; Lillian Lai; Matthew R Cooperberg; Rebecca L Sudore; Salomeh Keyhani; I Elaine Allen; Louise C Walter Journal: Urology Date: 2021-05-15 Impact factor: 2.633