Literature DB >> 27861670

Primary and Secondary Stability of Implants in Postextraction and Healed Sites: A Randomized Controlled Clinical Trial.

Luciano Malchiodi, Lucio Balzani, Alessandro Cucchi, Paolo Ghensi, Pier Francesco Nocini.   

Abstract

PURPOSE: This randomized clinical trial aimed to investigate the relationships between insertion torque, implant stability quotient (ISQ), and crestal bone loss (CBL) of implants placed in fresh or 12-week healed extraction sites.
MATERIALS AND METHODS: Forty patients were randomly assigned to one of two groups and had one implant placed immediately (test group, n = 20) or 12 weeks after extraction (control group, n = 20) at premolar or molar sites. For all implants, insertion torque and ISQ scores at insertion and loading were recorded. Patients were followed for up to 12 months.
RESULTS: Implant success was 100% in both groups. No differences were observed concerning both ISQ at insertion and ISQ at loading. A stronger correlation was detected between ISQ at insertion and insertion torque in the postextractive group (R = 0.83), than in the delayed group (R = 0.39), while ISQ at loading and insertion torque showed no correlation. CBL at 12 months was significantly different between test (0.68 ± 0.43 mm) and control (0.40 ± 0.26 mm, P = .02) groups.
CONCLUSION: Implant placement timing (immediate or delayed) may affect correlation between insertion torque and ISQ at insertion with ISQ at loading. While insertion torque influences ISQ at insertion, it does not affect ISQ at loading because of successful osseointegration. Postextraction and delayed implants seem to have similar ISQ at insertion and at loading, but different CBL after 12 months of follow-up because of postextraction bone remodeling.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27861670     DOI: 10.11607/jomi.4710

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  7 in total

1.  [Immediate implantation following tooth extraction in fresh maxillary molar socket with poor bone quality].

Authors:  Jing Xu
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2019-01-30

2.  In vitro evaluation of the influence of bone cortical thickness on the primary stability of conventional- and short-sized implants.

Authors:  Luiz-Antônio-Borelli Barros; Caio-Fossalussa da Silva; Germana-de Villa Camargos; Elcio Marcantonio; Guilherme-José-Pimentel-Lopes de Oliveira; Luiz-Antônio-Borelli Barros-Filho
Journal:  J Clin Exp Dent       Date:  2022-02-01

3.  Implant Stability in the Posterior Maxilla: A Controlled Clinical Trial.

Authors:  Raquel Zita Gomes; Mario Ramalho de Vasconcelos; Isabel Maria Lopes Guerra; Rute Alexandra Borges de Almeida; Antonio Cabral de Campos Felino
Journal:  Biomed Res Int       Date:  2017-05-25       Impact factor: 3.411

4.  Rhamnolipid coating reduces microbial biofilm formation on titanium implants: an in vitro study.

Authors:  Erica Tambone; Emiliana Bonomi; Paolo Ghensi; Devid Maniglio; Chiara Ceresa; Francesca Agostinacchio; Patrizio Caciagli; Giandomenico Nollo; Federico Piccoli; Iole Caola; Letizia Fracchia; Francesco Tessarolo
Journal:  BMC Oral Health       Date:  2021-02-04       Impact factor: 2.757

5.  Under-Drilling versus Hybrid Osseodensification Technique: Differences in Implant Primary Stability and Bone Density of the Implant Bed Walls.

Authors:  Rafael Delgado-Ruiz; Joshua Gold; Tanya Somohano Marquez; Georgios Romanos
Journal:  Materials (Basel)       Date:  2020-01-15       Impact factor: 3.623

Review 6.  Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis.

Authors:  Adam Ibrahim; Bruno Ramos Chrcanovic
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

7.  Dimensional Changes in the Alveolus after a Combination of Immediate Postextraction Implant and Connective Grafting and/or Socket Shield Technique.

Authors:  Ramón Gómez-Meda; María Rizo-Gorrita; María-Angeles Serrera-Figallo; Jonathan Esquivel; Cristina Herraez-Galindo; Daniel Torres-Lagares
Journal:  Int J Environ Res Public Health       Date:  2022-02-27       Impact factor: 3.390

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.