Parasympathetic tone variations according to umbilical cord pH at birth: a computerized fetal heart rate variability analysis.

Laura Butruille1, Julien De Jonckheere2,3, Mathilde Flocteil3, Charles Garabedian2,4, Véronique Houfflin-Debarge2,4, Laurent Storme2,5, Philippe Deruelle2,4, Régis Logier3.   

Abstract

Non-reassuring fetal heart rate tracings reflect an imbalance between the parasympathetic and sympathetic nervous systems. In this situation, fetal asphyxia can be suspected and may be confirmed by metabolic measurements at birth like low pH or high base deficit values. The objective of this study was to determine whether fetal asphyxia during labor is related to parasympathetic nervous system activity. This is a retrospective study of a database collected in 5 centers. Two hundred and ninety-nine fetal heart rate tracings collected during labor were analyzed. Autonomic nervous system, especially the parasympathetic nervous system, was analyzed using an original index: the FSI (Fetal Stress Index). The FSI is a parasympathetic activity evaluation based on fetal heart rate variability analysis. Infants were grouped based on normal or low pH value at birth. FSI was measured during the last 30 min of labor before birth and compared between groups. The minimum value of the FSI during the last 30 min before delivery was significantly lower in the group with the lower umbilical cord arterial pH value. In this pilot study during labor, FSI was lower in the group of infants with low arterial pH at birth.

Entities:  

Keywords:  Acidemia; Autonomic nervous system; Fetus; Heart rate variability; Umbilical cord pH

Mesh:

Year:  2016        PMID: 27848142     DOI: 10.1007/s10877-016-9957-y

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  39 in total

Review 1.  A template for defining a causal relation between acute intrapartum events and cerebral palsy: international consensus statement.

Authors:  A MacLennan
Journal:  BMJ       Date:  1999-10-16

2.  Computerized analysis of fetal heart rate variability using the matching pursuit technique as an indicator of fetal hypoxia during labor.

Authors:  E Salamalekis; E Hintipas; I Salloum; G Vasios; C Loghis; N Vitoratos; Ch Chrelias; G Creatsas
Journal:  J Matern Fetal Neonatal Med       Date:  2006-03

3.  Heart rate variability. Standards of measurement, physiological interpretation, and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology.

Authors: 
Journal:  Eur Heart J       Date:  1996-03       Impact factor: 29.983

4.  Inter- and intra-observer agreement of non-reassuring cardiotocography analysis and subsequent clinical management.

Authors:  Sarah Rhöse; Ayesha M F Heinis; Frank Vandenbussche; Joris van Drongelen; Jeroen van Dillen
Journal:  Acta Obstet Gynecol Scand       Date:  2014-04-15       Impact factor: 3.636

5.  Power spectrum analysis of heart rate fluctuation: a quantitative probe of beat-to-beat cardiovascular control.

Authors:  S Akselrod; D Gordon; F A Ubel; D C Shannon; A C Berger; R J Cohen
Journal:  Science       Date:  1981-07-10       Impact factor: 47.728

6.  Normalized spectral power of fetal heart rate variability is associated with fetal scalp blood pH.

Authors:  J O E H van Laar; C H L Peters; S Houterman; P F F Wijn; A Kwee; S G Oei
Journal:  Early Hum Dev       Date:  2011-04       Impact factor: 2.079

7.  Variations of the analgesia nociception index during general anaesthesia for laparoscopic abdominal surgery.

Authors:  M Jeanne; C Clément; J De Jonckheere; R Logier; B Tavernier
Journal:  J Clin Monit Comput       Date:  2012-03-28       Impact factor: 2.502

Review 8.  [Physiologic basis for fetal heart rate analysis during labour].

Authors:  M Doret; A Constans; P Gaucherand
Journal:  J Gynecol Obstet Biol Reprod (Paris)       Date:  2010-03-02

9.  Heart rate variability analysis allows early asphyxia detection in ovine fetus.

Authors:  Martin G Frasch; Thomas Müller; Christian Weiss; Karin Schwab; Harald Schubert; Matthias Schwab
Journal:  Reprod Sci       Date:  2009-01-22       Impact factor: 3.060

Review 10.  Long-term neurodevelopmental outcomes after intrauterine and neonatal insults: a systematic review.

Authors:  Michael K Mwaniki; Maurine Atieno; Joy E Lawn; Charles R J C Newton
Journal:  Lancet       Date:  2012-01-13       Impact factor: 79.321

View more
  3 in total

1.  Fetal heart rate variability analysis for neonatal acidosis prediction.

Authors:  M-A Gatellier; J De Jonckheere; L Storme; V Houfflin-Debarge; L Ghesquiere; C Garabedian
Journal:  J Clin Monit Comput       Date:  2020-05-25       Impact factor: 2.502

2.  Correlation of a new index reflecting the fluctuation of parasympathetic tone and fetal acidosis in an experimental study in a sheep model.

Authors:  C Garabedian; Y Clermont-Hama; D Sharma; E Aubry; L Butruille; P Deruelle; L Storme; J De Jonckheere; V Houfflin-Debarge
Journal:  PLoS One       Date:  2018-01-10       Impact factor: 3.240

3.  Comparison of fetal heart rate variability by symbolic dynamics at the third trimester of pregnancy and low-risk parturition.

Authors:  Cristian Iván Montalvo-Jaramillo; Adriana Cristina Pliego-Carrillo; Miguel Ángel Peña-Castillo; Juan Carlos Echeverría; Enrique Becerril-Villanueva; Lenin Pavón; Rodrigo Ayala-Yáñez; Ramón González-Camarena; Karsten Berg; Niels Wessel; Gustavo Pacheco-López; José Javier Reyes-Lagos
Journal:  Heliyon       Date:  2020-03-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.