Literature DB >> 27847692

Aqueous Angiography with Fluorescein and Indocyanine Green in Bovine Eyes.

Alex S Huang1, Sindhu Saraswathy2, Anna Dastiridou2, Alan Begian1, Hanz Legaspi1, Chirayu Mohindroo2, James C H Tan1, Brian A Francis1, Joseph Caprioli3, David R Hinton4, Robert N Weinreb5.   

Abstract

PURPOSE: We characterize aqueous angiography as a real-time aqueous humor outflow imaging (AHO) modality in cow eyes with two tracers of different molecular characteristics.
METHODS: Cow enucleated eyes (n = 31) were obtained and perfused with balanced salt solution via a Lewicky AC maintainer through a 1-mm side-port. Fluorescein (2.5%) or indocyanine green (ICG; 0.4%) were introduced intracamerally at 10 mm Hg individually or sequentially. With an angiographer, infrared and fluorescent images were acquired. Concurrent anterior segment optical coherence tomography (OCT) was performed, and fixable fluorescent dextrans were introduced into the eye for histologic analysis of angiographically positive and negative areas.
RESULTS: Aqueous angiography in cow eyes with fluorescein and ICG yielded high-quality images with segmental patterns. Over time, ICG maintained a better intraluminal presence. Angiographically positive, but not negative, areas demonstrated intrascleral lumens with anterior segment OCT. Aqueous angiography with fluorescent dextrans led to their trapping in AHO pathways. Sequential aqueous angiography with ICG followed by fluorescein in cow eyes demonstrated similar patterns.
CONCLUSIONS: Aqueous angiography in model cow eyes demonstrated segmental angiographic outflow patterns with either fluorescein or ICG as a tracer. TRANSLATIONAL RELEVANCE: Further characterization of segmental AHO with aqueous angiography may allow for intelligent placement of trabecular bypass minimally invasive glaucoma surgeries for improved surgical results.

Entities:  

Keywords:  angiography; aqueous angiography; fluorescein angiography; minimally invasive glaucoma surgeries

Year:  2016        PMID: 27847692      PMCID: PMC5106193          DOI: 10.1167/tvst.5.6.5

Source DB:  PubMed          Journal:  Transl Vis Sci Technol        ISSN: 2164-2591            Impact factor:   3.283


Introduction

Some minimally invasive glaucoma surgeries (MIGS) attempt trabecular meshwork (TM) ablation or bypass to lower intraocular pressure (IOP) for ocular hypertension treatment in glaucoma. Results demonstrate IOP lowering but inconsistent success.[1,2] One hypothesis to explain this variability is that consistent placement of these surgeries (always in the nasal quadrant of the eye) in the setting of inconsistent aqueous humor outflow (AHO) anatomy[3] may be the problem. Multiple methods have demonstrated segmental AHO as opposed to 360° uniform and circumferential AHO patterns.[4-18] Aqueous angiography is a form of anterior segment fluorescent angiography[19] that has been reported recently as a real-time AHO imaging method in model pig and human eyes.[4] Aqueous angiography in model human eyes has shown that AHO patterns not only can differ among individual humans but also between the two eyes of a single individual.[4] Ideally, AHO imaging should be able to be used clinically in patients and also be real-time and physiologic (performed at normal IOP levels). It should not exclude any portion of AHO pathways either circumferentially around the limbus or linearly from the anterior chamber (AC) to the distal outflow pathways. Aqueous angiography meets each of these criteria except for being conducted in a clinical setting with patients. Currently, aqueous angiography is performed in postmortem enucleated model eyes. While ex vivo testing provides an investigative tool for understanding AHO biology, it does have certain limitations.[4] First, cellular viability and episcleral venous blood clotting could affect AHO patterns. Second, with enucleated eyes it is difficult to test interventions. After the introduction of any tracer into the AC, the tracer ultimately accumulates on the ocular surface at severed episcleral veins.[3,20] This normally would not happen in test subjects with intact eyes as tracer leaving the AC eventually moves out of the eye through the episcleral veins and towards the systemic venous circulation. Given this limitation, one cannot perform aqueous angiography, document an angiographic pattern, conduct a manipulation (pharmacologic or surgical), and repeat aqueous angiography to query the effects. The tracer from the first aqueous angiography is simply spread throughout. Thus, a second tracer is needed. Characterizing aqueous angiography with multiple tracers also is important for more than just testing interventions. Recall that any tracer study is limited by the unique molecular characteristics of each tested tracer. For example, for retinal blood flow, the lack of choroidal visualization by fluorescein did not mean that there was no choroidal vasculature. Instead, indocyanine green (ICG) needed to be introduced with increased molecular weight, protein binding, longer excitation/emission wavelength profiles, and intraluminal retention to demonstrate choroidal vessels.[21] For AHO, aqueous humor is the substance of interest. Like blood for retinal vascular flow, aqueous has different properties than previously described tracers, such as microbeads[8,17,18] or fluorescein (that our group used for aqueous angiography).[4] Fortunately though, microbeads and fluorescein have shown similar segmental AHO patterns, and this is encouraging. The purpose of the current study is to evaluate aqueous angiography in cow with additional dyes (fluorescein and ICG) either individually or in sequence. Additional characterization of aqueous angiography AHO imaging in another species and dye further reassures that previously observed segmental AHO patterns were neither species- nor dye-specific. Use of multiple dyes also may allow for creation of a testable system.

Methods

Aqueous Angiography

Aqueous angiography was performed as described previously (Fig. 1).[4] Cow eyes (n = 31) were obtained from abattoirs (<2 years old; Manning Beef LLC, Pico Rivera, CA) and shipped on blue ice within 6 hours of death. Only cow eyes with circumferential white conjunctivae were used for experiments. Eyes were trimmed of extraocular tissue, orientated by inferior oblique insertion location,[22] and pinned to Styrofoam. A Lewicky AC maintainer (BVI Visitec, Abingdon, Oxfordshire, UK) was inserted through a 1-mm sideport into the AC. Balanced salt solution (BSS; Alcon, Ft. Worth, TX) was introduced for a 1-hour preperfusion period at room temperature (RT) with a reservoir height set at 5 inches above the eye to provide an IOP of approximately 10 mm Hg.[4] Eyes were kept moist with RT BSS-soaked gauze. Simultaneously, 25% fluorescein (Akorn Pharmaceuticals, Lake Forest, IL) was diluted at RT in BSS to 2.5%, or indocyanine green (ICG; Sigma I2633; Sigma-Aldrich Corp., St. Louis, MO) was dissolved with water into a 2% stock solution. Indocyanine green was subsequently diluted in BSS to 0.4%. These exact concentrations were chosen because they have been described for clinical use in live humans as intraocular capsular stains for cataract surgery.[23] Before imaging, aqueous humor was exchanged with 2.5% fluorescein (n = 10) or 0.4% ICG (n = 10) in BSS with a reservoir height set for 10 mm Hg. Alternatively, 3 kD fixable and fluorescent dextrans (diluted to 2.5 mg/mL in BSS; Life Technologies, Carlsbad, CA) were used (n = 3).[4,24,25]
Figure 1

Aqueous angiography in post-mortem eyes. (A) Aqueous angiography was performed by obtaining postmortem eyes, trimming excess extraocular tissue, and pinning posterior muscles and tissue to a Styrofoam face. Inferior, the AC-maintainer entered the AC. Note that the face had holes cut out where the eyes would be located to situate and secure the postmortem eye without excessive ocular surface strain. Discoloration of Styrofoam was from prior use and staining from fluorescent dyes. (B) Using the Spectralis HRA+OCT (Heidelberg Engineering), which is a clinical device for human imaging, the chin of the Styrofoam face was placed in the chin rest similar to how a live patient would be imaged in the clinic.

Aqueous angiography in post-mortem eyes. (A) Aqueous angiography was performed by obtaining postmortem eyes, trimming excess extraocular tissue, and pinning posterior muscles and tissue to a Styrofoam face. Inferior, the AC-maintainer entered the AC. Note that the face had holes cut out where the eyes would be located to situate and secure the postmortem eye without excessive ocular surface strain. Discoloration of Styrofoam was from prior use and staining from fluorescent dyes. (B) Using the Spectralis HRA+OCT (Heidelberg Engineering), which is a clinical device for human imaging, the chin of the Styrofoam face was placed in the chin rest similar to how a live patient would be imaged in the clinic. In some cases, (n = 3 eyes) ICG was first introduced for aqueous angiography followed by exchange with fluorescein for aqueous angiography again in the same eye. Indocyanine green was given before fluorescein based on fluorescent imaging results with standard solutions. In these experiments, fluorescein and ICG fluorescent images were taken with the Spectralis HRA+OCT (fluorescein capture mode excitation wavelength, 486 nm and transmission filter set at >500 nm; ICG capture mode excitation wavelength, 786 nm and transmission filter set at >800 nm; Heidelberg Engineering, Heidelberg, Germany) with four conditions (n = 3 each; 500 μL in Eppendorf tubes): (1) BSS alone, (2) 2.5% fluorescein in BSS (F-BSS), (3) 0.4% ICG in BSS (ICG-BSS), and (4) a combination of 2.5% fluorescein and 0.4% ICG in BSS (COMBO). Identical sensitivity settings were used across conditions for the fluorescein and ICG capture mode, respectively. Regions of interest (ROI; 250 × 250 pixels) were placed over each image, and total pixel intensity was determined (Photoshop CS5 v.12x32; Adobe Systems, San Jose, CA). Statistical comparisons between different conditions were conducted with paired 2-sample Student's t-tests (Microsoft Excel 2010; Microsoft Corp., Redmond, WA). For the cow eyes themselves, aqueous angiography was performed as previously described[4] with the Spectralis HRA+OCT and imaging with a 55° lens with a 25 diopter focus. Confocal scanning laser ophthalmoscopic (cSLO) infrared images were taken to center the eye. Before tracer application, cSLO fluorescent angiographic images with the fluorescein or ICG capture mode were taken to provide a standard pretracer image that appeared black. Subsequent fluorescein or ICG capture mode images were acquired at different time points in various positions or face-on after tracer introduction. Face-on imaging (as opposed to tangential imaging) was required if two different regions of the eye were to be compared. To prevent image signal intensity saturation during prolonged imaging sessions, the laser sensitivity setting on the Spectralis was adjusted with each image to set the central fluorescent signal in the AC to just under signal saturation.

Aqueous Angiography Image Processing

Aqueous angiographic images were opened in Photoshop CS5 (v.12x32) for image processing and pixel intensity measurements. For quantitation, images were processed as previously reported.[4] Since the AC maintainer was made of metal, the angiographic signal immediately below the AC maintainer was dark. However, this was a small area, and for consistency this area was carried through all images within each imaging set (one eye using one dye). Briefly, an angiographic signal within the AC and beyond the globe equator for each eye was cropped to create a ring of angiographic data. The background fluorescent signal then was established by determining “average background pixel intensity” from a region of interest in the center of each eye from the pretracer image mentioned above. Average pixel intensities for all rings were obtained and background adjusted by subtracting out the “average background pixel intensity.” To control for manual adjustments to the Spectralis laser sensitivity settings during image acquisition, the background adjusted average pixel intensity from each ring was divided by the numerical value on the Spectralis laser sensitivity setting to yield a normalized intensity value.

Optical Coherence Tomography (OCT)

Anterior segment OCT (n = 3) was concurrently conducted in some instances of aqueous angiography to determine if angiographically positive regions showed vessel anatomy compatible with AHO. The anterior segment module (Heidelberg Engineering) on Sclera Mode was used. Single line scans with a 15° scan angle (3.9 μm axial and 11 μm lateral resolution; ∼4.5 mm) were taken with oversampling (ART = 20) in angiographically positive/negative regions.

Histologic Processing and Microscopy

After aqueous angiography with fluorescent dextrans for approximately 2 minutes, the intracameral fluorescent dextran solution was exchanged with 4% paraformaldehyde (PFA) for 15 minutes at 10 mm Hg. The entire globe then was placed in 4% PFA for an additional 15 minutes of fixation. Wedges including the angle were cut from angiographically positive and negative regions, dehydrated through ethanol steps, brought through xylenes, and paraffin embedded. Sections 5 μm thick were cut on a Leitz 1512 microtome (Leica Biosystems, Vista, CA) onto Superfrost Plus slides (VWR, Randor, PA) and air dried. Sections were deparaffinized through xylenes and rehydrated through diminishing ethanol steps. Slides were mounted with a 4′,6-diamidino-2-phenylendole (DAPI) containing mounting medium (Vector Labs, Burlingame, CA), and viewed under a Keyence BZ-X700 digital imaging microscope (Keyence, Chicago, IL). Sections were imaged with a ×4 plan-fluor lens with a 0.13 numerical aperture. All images were taken with identical settings for illumination and image capture sensitivity (Keyence imaging software v.1.51). For fluorescein isothiocyanate (FITC)–dextrans (EX BP 470/30, DM 495, EM BP 520/35) and DAPI (EX BP 360/40, DM 400, EM BP 460/50) appropriate filters were used, respectively. Fluorescent quantitative analyses was done as described previously.[4] Briefly, after removal of nonspecific Descemet's membrane signal, average fluorescence pixel intensity was determined in an ROI centered on the angle (Photoshop CS5 v.12x32) from which background signal in each slide (determined by sampling empty AC) was subtracted to obtain a background adjusted intensity value. Statistical comparisons of the background adjusted intensity values were conducted with 2-sample, equal sized, unpaired, assumed equal variance Student's t-tests.

Results

Aqueous Angiography in Cow with Fluorescein and ICG

Similar to pig and human,[4] aqueous angiography in cow demonstrated segmental patterns. With fluorescein and ICG, cow eyes showed perilimbal segmental regions of angiographic signal (Figs. 2, 3; arrowheads), perilimbal segmental regions without angiographic signal (Figs. 2, 3; arrows), and areas of distal signal (Figs. 2, 3; asterisks). When tested in separate eyes and imaging with a face-on view to capture angiographic signal circumferentially around the eye simultaneously, angiographic signal with fluorescein (n = 10) and ICG (n = 10) increased with time and started to plateau (Figs. 4 A–D). The total and rate of signal intensity increase for ICG appeared less and slower than that of fluorescein (Figs. 4E, 4F). When captured from a tangential view, fluorescein aqueous angiography signal initially appeared distinct eventually leading to diffusion and leakage over the space (Figs. 5A, 5B). Alternatively, ICG had more clearly defined angiographic patterns seen even after longer perfusions (Figs. 5C, 5D).
Figure 2

Aqueous angiography with fluorescein in bovine eyes. Images from different positions were taken on a representative cow eye using fluorescein for aqueous angiography demonstrating segmental and differentially emphasized angiographic patterns. Arrowheads denoted regions of perilimbal signal, and asterisks highlighted regions of distal signal. Arrows showed areas of relatively low perilimbal signal. The central image was a composite image of cSLO infrared (left side) and preinjection background (right side) images. Sup superior; Temp, temporal; Nas, nasal; Inf, inferior. Scale bar: 1 cm.

Figure 3

Aqueous angiography with ICG in bovine eyes. Images from different positions were taken on a representative cow eye using ICG for aqueous angiography demonstrating segmental and differentially emphasized angiographic patterns. Arrowheads denoted regions of perilimbal signal, and asterisks highlighted regions of distal signal. Arrows showed areas of relatively low perilimbal signal. The central image was a composite image of cSLO infrared (left side) and preinjection background (right side) images. Note that the preinjection background was even less intense than that of the stained Styrofoam (polygonal background pattern) that the eye was attached to. Scale bar: 1 cm.

Figure 4

Aqueous angiograph signal intensity rose over time in cow eyes. (A, B) Aqueous angiography with fluorescein over time demonstrated accumulated signal intensity (arrowheads). (C, D) Aqueous angiography with ICG over time also demonstrated accumulated signal intensity (arrowheads). (A–D) With fluorescein and ICG, areas with less signal intensity stayed stable (arrows). Total normalized pixel intensity values from 10 eyes each for (E) fluorescein and (F) ICG were recorded as a function of time at 10 mm Hg with ICG demonstrating a smaller and slower rise in signal intensity. Graphs showed mean ± SE. min, minutes. Scale bars: 1 cm.

Figure 5

Aqueous angiography comparing fluorescein (fluoro) to ICG. (A–D) Aqueous angiography from a tangential as opposed to a face-on view provided a better image of outflow pathway branching. Face-on images distorted aqueous angiography patterns due to the globe curvature. (A, B) Fluorescein aqueous angiography over time initially showed sharply demarcated angiographic patterns that became diffuse with time likely secondary to leakage. (C, D) Alternatively, ICG aqueous angiography signal increased in brightness over time but mostly maintained sharply demarcated patterns with better retained intraluminal presence. Scale bars: 1 cm.

Aqueous angiography with fluorescein in bovine eyes. Images from different positions were taken on a representative cow eye using fluorescein for aqueous angiography demonstrating segmental and differentially emphasized angiographic patterns. Arrowheads denoted regions of perilimbal signal, and asterisks highlighted regions of distal signal. Arrows showed areas of relatively low perilimbal signal. The central image was a composite image of cSLO infrared (left side) and preinjection background (right side) images. Sup superior; Temp, temporal; Nas, nasal; Inf, inferior. Scale bar: 1 cm. Aqueous angiography with ICG in bovine eyes. Images from different positions were taken on a representative cow eye using ICG for aqueous angiography demonstrating segmental and differentially emphasized angiographic patterns. Arrowheads denoted regions of perilimbal signal, and asterisks highlighted regions of distal signal. Arrows showed areas of relatively low perilimbal signal. The central image was a composite image of cSLO infrared (left side) and preinjection background (right side) images. Note that the preinjection background was even less intense than that of the stained Styrofoam (polygonal background pattern) that the eye was attached to. Scale bar: 1 cm. Aqueous angiograph signal intensity rose over time in cow eyes. (A, B) Aqueous angiography with fluorescein over time demonstrated accumulated signal intensity (arrowheads). (C, D) Aqueous angiography with ICG over time also demonstrated accumulated signal intensity (arrowheads). (A–D) With fluorescein and ICG, areas with less signal intensity stayed stable (arrows). Total normalized pixel intensity values from 10 eyes each for (E) fluorescein and (F) ICG were recorded as a function of time at 10 mm Hg with ICG demonstrating a smaller and slower rise in signal intensity. Graphs showed mean ± SE. min, minutes. Scale bars: 1 cm. Aqueous angiography comparing fluorescein (fluoro) to ICG. (A–D) Aqueous angiography from a tangential as opposed to a face-on view provided a better image of outflow pathway branching. Face-on images distorted aqueous angiography patterns due to the globe curvature. (A, B) Fluorescein aqueous angiography over time initially showed sharply demarcated angiographic patterns that became diffuse with time likely secondary to leakage. (C, D) Alternatively, ICG aqueous angiography signal increased in brightness over time but mostly maintained sharply demarcated patterns with better retained intraluminal presence. Scale bars: 1 cm.

Aqueous Angiography in Cow Represents AHO

To test whether the angiographic signal in cow represented actual AHO, as opposed to ocular surface staining or collection of dye, anterior segment OCT and fluorescent dextran experiments were performed. During aqueous angiography with 2.5% fluorescein or 0.4% ICG at 10 mm Hg, concurrent anterior segment OCT was performed. With fluorescein, in angiographically-positive areas (Figs. 6A, 6E, 6G), OCT showed intrascleral lumens consistent with AHO pathways (Fig. 6B, 6F, 6H). However, angiographically-negative regions with fluorescein (Fig. 6C) did not demonstrate intrascleral lumens (Fig. 6D). Interestingly, when conducting anterior segment OCT over a fluorescein angiographic bifurcation (Figs. 6E, 6G), two lumens were present to account for each arm of the bifurcation (Figs. 6F, 6H). As the scan moved further inferior and away from the bifurcation point (Figs. 6E vs. 6G), the two lumens (Figs. 6F vs. 6H) moved further apart, supporting the interpretation that the angiographic signal represented AHO. For ICG, similar results were seen with angiographically-positive but not -negative (Figs. 6I vs. 6K) regions showing intrascleral lumens (Figs. 6J vs. 6L).
Figure 6

Aqueous angiography and OCT in cow eyes. Aqueous angiography was conducted in cow eyes in parallel with anterior segment OCT with fluorescein (A, C, E, G) or ICG (I, K). (A, E, G, I) Angiographically-positive areas demonstrated (B, F, H, J) intrascleral lumens on OCT (arrows). However, angiographically lacking areas (C, K) were (D, L) devoid of intrascleral lumens on OCT.

Aqueous angiography and OCT in cow eyes. Aqueous angiography was conducted in cow eyes in parallel with anterior segment OCT with fluorescein (A, C, E, G) or ICG (I, K). (A, E, G, I) Angiographically-positive areas demonstrated (B, F, H, J) intrascleral lumens on OCT (arrows). However, angiographically lacking areas (C, K) were (D, L) devoid of intrascleral lumens on OCT. Fluorescent dextran (3 kD) experiments also were conducted as they could be observed by aqueous angiography and then trapped with fixation due to an attached lysine moiety (n = 3). After aqueous angiography was performed, angiographically-positive and -negative areas were marked, and the eyes perfusion fixed to trap fluorescent dextrans to nearby AHO pathway lumens, including the TM and aqueous plexus (AP) (Figs. 7A, 7D). In species, such as pig and cow, a well-defined Schlemm's canal (SC) is replaced by a similar but more interwoven structure named the AP.[7,26] Paraffin sections were viewed with fluorescent microscopy. Angiographically-positive regions demonstrated greater dextran deposition in the angle compared to angiographically-negative areas (Figs. 7B, 7E [green lines from Figs. 7A, 7D] versus Figs. 7C, 7F [red lines from Figs. 7A, 7D]). Note similar nonspecific fluorescence of Descemet's membrane in all conditions (Fig. 7; asterisks). Quantitative comparison of background-adjusted intensity values in angiographically-positive compared to -negative areas showed a statistically significant increase (62.87 ± 10.58 vs. 22.52 ± 13.83; background adjusted intensity units; average ± SD; n = 12 sections for each condition; P < 0.001 unpaired 2-tailed Student's t-test).
Figure 7

Aqueous angiography localized to AHO pathways in cow eyes. Aqueous angiography was performed with 3 kD fixable fluorescent dextrans in cow eyes. Two representative eyes (A–C and D–F) are shown here. Angiographically positive (A, D; green lines) or diminished (A, D; red lines) regions were identified with aqueous angiography, marked, and prepared for paraffin sectioning. In the first eye (A–C), angiographically positive (green line in [A] corresponds to [B]) but not angiographically diminished (red line in [A] corresponds to [C]) regions showed trapping of dextrans within outflow pathways. In the second eye (D–F), angiographically positive (green line in [D] corresponds to [E]) but not angiographically lacking (red line in [D] corresponds to [F]) regions also showed trapping of dextrans within outflow pathways. Note similar degree of nonspecific fluorescence seen in strips of Descemet's membrane and iris edge in all cases (asterisks). As the fixable fluorescent dextrans were attached to nearby surfaces with fixation, nonspecific positive fluorescence lining the AC was expected after introduction of perfusion fixation. Scale bar: 100 μm.

Aqueous angiography localized to AHO pathways in cow eyes. Aqueous angiography was performed with 3 kD fixable fluorescent dextrans in cow eyes. Two representative eyes (A–C and D–F) are shown here. Angiographically positive (A, D; green lines) or diminished (A, D; red lines) regions were identified with aqueous angiography, marked, and prepared for paraffin sectioning. In the first eye (A–C), angiographically positive (green line in [A] corresponds to [B]) but not angiographically diminished (red line in [A] corresponds to [C]) regions showed trapping of dextrans within outflow pathways. In the second eye (D–F), angiographically positive (green line in [D] corresponds to [E]) but not angiographically lacking (red line in [D] corresponds to [F]) regions also showed trapping of dextrans within outflow pathways. Note similar degree of nonspecific fluorescence seen in strips of Descemet's membrane and iris edge in all cases (asterisks). As the fixable fluorescent dextrans were attached to nearby surfaces with fixation, nonspecific positive fluorescence lining the AC was expected after introduction of perfusion fixation. Scale bar: 100 μm.

Sequential Aqueous Angiography with ICG and Fluorescein

Sequential aqueous angiography with ICG followed by fluorescein allowed for a direct comparison of aqueous angiography between the two dyes in the same eyes. Indocyanine green was chosen as the first tracer based on “baseline” fluorescent imaging with ICG and fluorescein standards. Four conditions (n = 3 each) were created (BSS alone, F-BSS, ICG-BSS, and COMBO) with each imaged by fluorescein and ICG capture modes (Fig. 8). Fluorescein-BSS was statistically more fluorescent than BSS with a fluorescein (Fig. 8A; P < 0.001) but not ICG (Fig. 8B; P = 0.99) capture mode. ICG-BSS was statistically more fluorescent than BSS with ICG (Fig. 8B; P = 0.005) but not fluorescein capture mode (Fig. 8A; P = 0.20). However, while COMBO was not statistically different from F-BSS with fluorescein capture mode (Fig. 8A; P = 0.45), COMBO did show a large, unexpected, and statistically significant increase in fluorescence compared to ICG-BSS (Fig. 8B; P < 0.001) with ICG capture mode. Therefore, since it appeared that combining fluorescein and ICG influenced ICG but not fluorescein fluorescence in this system, we decided to conduct sequential fluorescence experiments only with ICG first, followed by fluorescein.
Figure 8

Fluorescence Intensity of fluorescein, ICG, and combination. Average fluorescence intensity was detected using fluorescein and ICG capture mode on standard solutions of BSS, F-BSS, ICG-BSS, and COMBO at equal molar concentrations of the dyes. (A) Using fluorescein capture mode, BSS and ICG-BSS showed little fluorescence. (A) F-BSS and COMBO showed increased fluorescence that was not statistically different from each other. (B) Using ICG capture mode, BSS and F-BSS showed little fluorescence. (B) However, while ICG-BSS showed an expected increased fluorescence, COMBO showed an unexpected larger increase in fluorescence that was statistically greater than ICG-BSS alone.

Fluorescence Intensity of fluorescein, ICG, and combination. Average fluorescence intensity was detected using fluorescein and ICG capture mode on standard solutions of BSS, F-BSS, ICG-BSS, and COMBO at equal molar concentrations of the dyes. (A) Using fluorescein capture mode, BSS and ICG-BSS showed little fluorescence. (A) F-BSS and COMBO showed increased fluorescence that was not statistically different from each other. (B) Using ICG capture mode, BSS and F-BSS showed little fluorescence. (B) However, while ICG-BSS showed an expected increased fluorescence, COMBO showed an unexpected larger increase in fluorescence that was statistically greater than ICG-BSS alone. With serial aqueous angiography using ICG followed by fluorescein in cow eyes (Fig. 9), similar but not identical patterns were observed. Regions of angiographic signal arose in relatively the same order (Figs. 9B–D and 9F–H; arrows), and regions devoid of angiographic signal maintained the same patterns (Figs. 9B–D and 9F–H; asterisks). Note that the background fluorescent image with fluorescein capture mode after ICG angiography but before fluorescein introduction (Fig. 9E) was devoid of fluorescent signal. Tangential views, minimizing the effect of globe curvature seen with face-on views, further supported that areas with angiographic signal (Figs. 9I–L; arrows) or lack thereof (Figs. 9I–L; asterisks) were very similar between ICG and fluorescein.
Figure 9

Sequential Aqueous angiography with ICG followed by fluorescein (Fluoro) demonstrated similar patterns. Sequential aqueous angiography was performed first with ICG followed by fluorescein. (A–H) Sequential aqueous angiography was conducted in one cow eye with (B–D) ICG administration and ICG capture mode before (F–H) fluorescein administration and fluorescein capture mode over time. (A, E) Background images demonstrated lack of fluorescence with appropriate capture modes. (A–H) Comparing the ICG and fluorescein patterns, regions with (arrows) and without (asterisks) angiographic signal were similar. Tangential imaging with sequential aqueous angiography using ICG first followed by fluorescein in two additional eyes ([I, J] and [K, L]) also showed the same result in that regions with (arrows) and without (asterisks) angiographic signal appeared similar comparing the two dyes. Scale bars: 1 cm.

Sequential Aqueous angiography with ICG followed by fluorescein (Fluoro) demonstrated similar patterns. Sequential aqueous angiography was performed first with ICG followed by fluorescein. (A–H) Sequential aqueous angiography was conducted in one cow eye with (B–D) ICG administration and ICG capture mode before (F–H) fluorescein administration and fluorescein capture mode over time. (A, E) Background images demonstrated lack of fluorescence with appropriate capture modes. (A–H) Comparing the ICG and fluorescein patterns, regions with (arrows) and without (asterisks) angiographic signal were similar. Tangential imaging with sequential aqueous angiography using ICG first followed by fluorescein in two additional eyes ([I, J] and [K, L]) also showed the same result in that regions with (arrows) and without (asterisks) angiographic signal appeared similar comparing the two dyes. Scale bars: 1 cm.

Discussion

Aqueous angiography in model pig and human eyes previously demonstrated segmental AHO patterns.[4] Similar results reported here in another species (cow) with an additional tracer confirmed that segmental aqueous angiography patterns were neither species- nor dye-specific. However, limitations of aqueous angiography remain. Use of enucleated eyes may have caused artifacts related to changes in cellular viability, postmortem tissue swelling, and blood clotting in episcleral veins. Future in vivo studies will be critical to addressing each of these concerns. Use of ICG as a second dye also more than just confirmed segmental AHO patterns. This dye offers certain advantages over fluorescein given its unique molecular characteristics (larger molecular weight, protein binding, and longer excitation/emission wavelength profiles) that are well-known in the posterior segment to enhance choroidal vasculature imaging.[21] Therefore, it was not surprising that ICG aqueous angiography provided fine detail of the AHO anatomy in the anterior segment, as well. ICG green maintained an intraluminal presence better than fluorescein. Unlike fluorescein, ICG did not leak out of AHO pathways onto the perivascular sclera. In contrast, visualization of ICG took longer to be observed compared to fluorescein, and this likely had to do in part with its lower concentration. ICG green concentrations unfortunately are limited by its solubility in saline solutions.[27] Nevertheless, the concentrations of fluorescein and ICG chosen here were based on clinically applicable concentrations that are suitable for intraocular delivery as performed for capsular staining in cataract surgery.[23] Addition of a second dye also allowed for the creation of a potentially testable system. In an enucleated eye, aqueous angiography with any tracer would lead to its accumulation on the ocular surface because the full outflow pathway is disrupted at cut episcleral veins. Therefore, aqueous angiography could not be used to determine an AHO pattern, perform an experimental manipulation, and be repeated with the same tracer to assess the effect of the manipulation. The introduction of a second tracer addressed this problem. Of course, ICG had to be introduced before fluorescein in this report. In this investigation, when imaging standard tracer solutions, the combination of ICG with fluorescein seemed to potentiate ICG's total fluorescence. While, ICG and fluorescein are known to have disparate excitation:emission profiles (fluorescein excitation, ∼400–525 nm, peak ∼490 nm[28]; fluorescein emission, ∼ 474–650 nm, peak ∼512 nm[28]; ICG excitation, ∼575–875 nm, peak ∼800 nm[29,30]; ICG emission, 775–900 nm, peak ∼835 nm[30]) fluorescent cross-talk may be occurring. Fluorescent resonance energy transfer (FRET) is a commonly used strategy that intentionally takes advantage of fluorescent cross-talk for biological assays.[31] At higher concentrations, fluorescein is known to undergo an inner-filter effect[32,33] where the fluorescein emission itself, which can be as high as 650 nm and notably longer than typical fluorescein excitation wavelengths, can actually excite nearby fluorescein molecules. Therefore, we speculate that the ICG capture mode laser (786 nm) could have excited fluorescein when prepared in combination and caused fluorescein emission that further stimulated ICG. Due to this observation, the influence of fluorescein on ICG imaging at these concentrations with the Spectralis HRA+OCT for the anterior segment requires further investigation. Despite any potential influence fluorescein has on ICG, ICG did not affect fluorescein fluorescence in the fluorescein capture mode in carefully controlled experiments (Fig. 8A). Therefore, use of ICG before fluorescein for sequential aqueous angiography was valid. In this arrangement, sequential aqueous angiography showed similar patterns and, thus, could be used to test manipulations. Such a paradigm has the potential to be used for drug screening and evaluation of novel trabecular bypass surgical techniques. A similar paradigm has been described with a two color microbead system.[18] The advantages there are that the two tracers are more similar in characteristics and that microbeads may model larger components of aqueous with better maintained intraluminal presence than small molecule dyes. The advantages of aqueous angiography herein are that the system better models the liquid component of aqueous humor and that real-time images can be acquired. Aqueous angiography also allows for possible delicate biochemical and molecular studies comparing regions of higher or lesser angiographic signal. Recall, that while alterations have been found in glaucoma outflow pathways, conclusive and reproducible pathologic findings have been elusive[16,20] and thought to be due to differences in tissue procurement, tissue processing, or fixation methods. An alternative hypothesis for this variability is that reproducible pathologic findings comparing normal and glaucomatous tissue were inherently difficult if tissues in both cases were sampled throughout the eye without regard to pretest knowledge of whether the region supported greater or lesser AHO. Therefore, experiments are under way to perform aqueous angiography in cow and human eyes, collect relevant tissue, such as TM, and look for differences in extracellular matrix, cytoskeleton, or TGF-β–mediated fibrotic pathways. In conclusion, aqueous angiography in cow further confirmed segmental AHO patterns in the eye of another species. Using two dyes demonstrating similar patterns was additionally reassuring and now allows for the possibility of testing interventions (pharmacologic, surgical, or IOP-related). Distinguishing regions of high or low angiographic signal allows for tissue segregation and enrichment of differences to permit finer molecular comparisons. In the future, we plan aqueous angiography with multiple tracers in live animals and human subjects. These studies will be very important because human and nonhuman primate eyes are different from cow eyes. Primarily, cows do not have a Schlemm's canal but instead an analogous structure called an aqueous plexus.[7,26] The aqueous plexus is more like a meshwork continuation leading to openings into distal outflow pathways. Clinically, aqueous angiography may have a role in pre- or intraoperative outflow assessment to query individual human AHO patterns to guide MIGS toward optimized results.
  31 in total

1.  Fluorescence: basic concepts, practical aspects, and some anecdotes.

Authors:  David M Jameson; John C Croney; Pierre D J Moens
Journal:  Methods Enzymol       Date:  2003       Impact factor: 1.600

Review 2.  'What controls aqueous humour outflow resistance?'.

Authors:  Mark Johnson
Journal:  Exp Eye Res       Date:  2006-01-04       Impact factor: 3.467

3.  Cationic ferritin changes outflow facility in human eyes whereas anionic ferritin does not.

Authors:  C R Ethier; D W Chan
Journal:  Invest Ophthalmol Vis Sci       Date:  2001-07       Impact factor: 4.799

4.  Trabectome (trabeculectomy-internal approach): additional experience and extended follow-up.

Authors:  Don Minckler; Sameh Mosaed; Laurie Dustin; Brian Francis Ms
Journal:  Trans Am Ophthalmol Soc       Date:  2008

5.  Effects of Y27632 on aqueous humor outflow facility with changes in hydrodynamic pattern and morphology in human eyes.

Authors:  Chen-Yuan Charlie Yang; Ye Liu; Zhaozeng Lu; Ruiyi Ren; Haiyan Gong
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-08-28       Impact factor: 4.799

Review 6.  Excitation energy transfer and trapping in dye-loaded solid particles.

Authors:  Hernán B Rodríguez; Enrique San Román
Journal:  Ann N Y Acad Sci       Date:  2008       Impact factor: 5.691

7.  H-7 effects on the structure and fluid conductance of monkey trabecular meshwork.

Authors:  I Sabanay; B T Gabelt; B Tian; P L Kaufman; B Geiger
Journal:  Arch Ophthalmol       Date:  2000-07

8.  Light-absorbing properties, stability, and spectral stabilization of indocyanine green.

Authors:  M L Landsman; G Kwant; G A Mook; W G Zijlstra
Journal:  J Appl Physiol       Date:  1976-04       Impact factor: 3.531

9.  Partitioning of the aqueous outflow in rat eyes.

Authors:  James D Lindsey; Anthony Hofer; Kristine N Wright; Robert N Weinreb
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-09-24       Impact factor: 4.799

10.  Mapping molecular differences and extracellular matrix gene expression in segmental outflow pathways of the human ocular trabecular meshwork.

Authors:  Janice A Vranka; John M Bradley; Yong-Feng Yang; Kate E Keller; Ted S Acott
Journal:  PLoS One       Date:  2015-03-31       Impact factor: 3.240

View more
  23 in total

1.  Gravitational Influence on Intraocular Pressure: Implications for Spaceflight and Disease.

Authors:  Alex S Huang; Michael B Stenger; Brandon R Macias
Journal:  J Glaucoma       Date:  2019-08       Impact factor: 2.503

2.  Automated circumferential construction of first-order aqueous humor outflow pathways using spectral-domain optical coherence tomography.

Authors:  Alex S Huang; Akram Belghith; Anna Dastiridou; Vikas Chopra; Linda M Zangwill; Robert N Weinreb
Journal:  J Biomed Opt       Date:  2017-06-01       Impact factor: 3.170

Review 3.  Precision medicine to prevent glaucoma-related blindness.

Authors:  Sayoko E Moroi; David M Reed; David S Sanders; Ahmed Almazroa; Lawrence Kagemann; Neil Shah; Nakul Shekhawat; Julia E Richards
Journal:  Curr Opin Ophthalmol       Date:  2019-05       Impact factor: 3.761

4.  Cellular and cytoskeletal alterations of scleral fibroblasts in response to glucocorticoid steroids.

Authors:  Thania Bogarin; Sindhu Saraswathy; Goichi Akiyama; Xiaobin Xie; Robert N Weinreb; Jie Zheng; Alex S Huang
Journal:  Exp Eye Res       Date:  2019-08-23       Impact factor: 3.467

5.  Fluorescein Aqueous Angiography in Live Normal Human Eyes.

Authors:  Alex S Huang; Rafaella C Penteado; Sajib K Saha; Jiun L Do; Philip Ngai; Zhihong Hu; Robert N Weinreb
Journal:  J Glaucoma       Date:  2018-11       Impact factor: 2.503

6.  Functional, structural, and molecular identification of lymphatic outflow from subconjunctival blebs.

Authors:  Goichi Akiyama; Sindhu Saraswathy; Thania Bogarin; Xiaojing Pan; Ernesto Barron; Tina T Wong; Mika K Kaneko; Yukinari Kato; Young Hong; Alex S Huang
Journal:  Exp Eye Res       Date:  2020-05-06       Impact factor: 3.467

7.  Segmental differences found in aqueous angiographic-determined high - and low-flow regions of human trabecular meshwork.

Authors:  Sindhu Saraswathy; Thania Bogarin; Ernesto Barron; Brian A Francis; James C H Tan; Robert N Weinreb; Alex S Huang
Journal:  Exp Eye Res       Date:  2020-05-18       Impact factor: 3.467

8.  Aqueous Angiography: Aqueous Humor Outflow Imaging in Live Human Subjects.

Authors:  Alex S Huang; Andrew Camp; Benjamin Y Xu; Rafaella C Penteado; Robert N Weinreb
Journal:  Ophthalmology       Date:  2017-04-28       Impact factor: 12.079

9.  Microcatheter-assisted Trabeculotomy for Primary Congenital Glaucoma After Failed Glaucoma Surgeries.

Authors:  Man Hu; Huaizhou Wang; Alex S Huang; Li Li; Yan Shi; Yongli Xu; Ningli Wang
Journal:  J Glaucoma       Date:  2019-01       Impact factor: 2.503

Review 10.  Structural and functional imaging of aqueous humour outflow: a review.

Authors:  Alex S Huang; Brian A Francis; Robert N Weinreb
Journal:  Clin Exp Ophthalmol       Date:  2017-10-12       Impact factor: 4.207

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.