Literature DB >> 27847117

Quantification of collagen fiber orientation in human tendons with the coefficient of variation of echogenicity.

Tomonobu Ishigaki1, Masahiro Kouno1, Toshihiro Ikebukuro1, Keitaro Kubo2.   

Abstract

The grayscale distribution on the ultrasonic images of tendons may be reduced with alignment of collagen fibers, because ultrasound signal intensity changes with alterations in tendon collagen fiber orientation due to acoustic anisotropy in the tendons. The purpose of this study was to investigate changes in the coefficient of variation (CV) of echogenicity in the Achilles tendon during passive dorsiflexion (the angle task) and isometric plantar flexion (the contraction task). Achilles tendon transverse ultrasonic images were collected from 14 healthy individuals every 10° from 20° to -20° (positive values for plantar flexion) in the angle task and every 10% maximum voluntary contraction (MVC) from 0% to 70% MVC in the contraction task. The CV of echogenicity was measured in each image. In addition, relative changes in the measured variables between the former half (20-0° in the angle task, 0% to 30% MVC in the contraction task) and the latter half (0° to -20° in the angle task, 40% to 70% MVC in the contraction task) of each task were compared. The CV of echogenicity decreased with increases in the dorsiflexion angle and intensity of isometric contractions. Furthermore, relative changes in the CV of echogenicity were greater at more dorsiflexed positions in the angle task and at lower torque levels in the contraction task. These results suggested that decreases in the CV of echogenicity were partially related to the alignment of the tendon collagen fibers with tendon stretching.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Achilles tendon; Echogenicity; In vivo; Ultrasound

Mesh:

Substances:

Year:  2016        PMID: 27847117     DOI: 10.1016/j.jbiomech.2016.11.004

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Effects of eccentric training with different training frequencies on blood circulation, collagen fiber orientation, and mechanical properties of human Achilles tendons in vivo.

Authors:  Tomonobu Ishigaki; Keitaro Kubo
Journal:  Eur J Appl Physiol       Date:  2018-09-10       Impact factor: 3.078

2.  Ankle Joint Position and the Reliability of Ultrasound Tissue Characterization of the Achilles Tendon: A Pilot Study.

Authors:  Arturo Lawson; Marika Noorkoiv; Lorenzo Masci; Amir A Mohagheghi
Journal:  Med Sci Monit       Date:  2019-09-13

3.  Tendon morphological changes after a prolonged ski race can be detected by ultrasound echo intensity.

Authors:  Alessandro Schneebeli; Lorenzo Visconti; Corrado Cescon; Ron Clijsen; Guido Giardini; Maria Elisabetta Arizzio; Marco Barbero
Journal:  J Foot Ankle Res       Date:  2020-06-10       Impact factor: 2.303

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.