Closed-loop insulin delivery in inpatients with type 2 diabetes: a randomised, parallel-group trial.

Hood Thabit1, Sara Hartnell2, Janet M Allen3, Andrea Lake4, Malgorzata E Wilinska3, Yue Ruan3, Mark L Evans1, Anthony P Coll1, Roman Hovorka5.   

Abstract

BACKGROUND: We assessed whether fully closed-loop insulin delivery (the so-called artificial pancreas) is safe and effective compared with standard subcutaneous insulin therapy in patients with type 2 diabetes in the general ward.
METHODS: For this single-centre, open-label, parallel-group, randomised controlled trial, we enrolled patients aged 18 years or older with type 2 diabetes who were receiving insulin therapy. Patients were recruited from general wards at Addenbrooke's Hospital, Cambridge, UK. Participants were randomly assigned (1:1) by a computer-generated minimisation method to receive closed-loop insulin delivery (using a model-predictive control algorithm to direct subcutaneous delivery of rapid-acting insulin analogue without meal-time insulin boluses) or conventional subcutaneous insulin delivery according to local clinical guidelines. The primary outcome was time spent in the target glucose concentration range of 5·6-10·0 mmol/L during the 72 h study period. Analyses were by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01774565.
FINDINGS: Between Feb 20, 2015, and March 24, 2016, we enrolled 40 participants, of whom 20 were randomly assigned to the closed-loop intervention group and 20 to the control group. The proportion of time spent in the target glucose range was 59·8% (SD 18·7) in the closed-loop group and 38·1% (16·7) in the control group (difference 21·8% [95% CI 10·4-33·1]; p=0·0004). No episodes of severe hypoglycaemia or hyperglycaemia with ketonaemia occurred in either group. One adverse event unrelated to study devices occurred during the study (gastrointestinal bleed).
INTERPRETATION: Closed-loop insulin delivery without meal-time boluses is effective and safe in insulin-treated adults with type 2 diabetes in the general ward. FUNDING: Diabetes UK; European Foundation for the Study of Diabetes; JDRF; National Institute for Health Research Cambridge Biomedical Research Centre; Wellcome Trust.
Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27836235     DOI: 10.1016/S2213-8587(16)30280-7

Source DB:  PubMed          Journal:  Lancet Diabetes Endocrinol        ISSN: 2213-8587            Impact factor:   32.069


  30 in total

Review 1.  Diabetes Technology in the Inpatient Setting for Management of Hyperglycemia.

Authors:  Georgia M Davis; Rodolfo J Galindo; Alexandra L Migdal; Guillermo E Umpierrez
Journal:  Endocrinol Metab Clin North Am       Date:  2020-03       Impact factor: 4.741

Review 2.  Automated Insulin Delivery in Adults.

Authors:  Charlotte K Boughton; Roman Hovorka
Journal:  Endocrinol Metab Clin North Am       Date:  2019-12-16       Impact factor: 4.741

Review 3.  Artificial Pancreas: Current Progress and Future Outlook in the Treatment of Type 1 Diabetes.

Authors:  Rozana Ramli; Monika Reddy; Nick Oliver
Journal:  Drugs       Date:  2019-07       Impact factor: 9.546

4.  Advancing the Use of CGM Devices in a Non-ICU Setting.

Authors:  Meng Wang; Lakshmi G Singh; Elias K Spanakis
Journal:  J Diabetes Sci Technol       Date:  2019-01-13

5.  Analyzing the Potential of Advanced Insulin Dosing Strategies in Patients With Type 2 Diabetes: Results From a Hybrid In Silico Study.

Authors:  Florian Reiterer; Matthias Reiter; Luigi Del Re; Merete Bechmann Christensen; Kirsten Nørgaard
Journal:  J Diabetes Sci Technol       Date:  2018-04-21

Review 6.  Advances in Closed-Loop Insulin Delivery Systems in Patients with Type 1 Diabetes.

Authors:  Vikash Dadlani; Jordan E Pinsker; Eyal Dassau; Yogish C Kudva
Journal:  Curr Diab Rep       Date:  2018-08-29       Impact factor: 4.810

7.  High Glucose Variability in Hospitalized Patients with Type 1 Diabetes Mellitus.

Authors:  Vikash Dadlani; Shrikant U Tamhane; Aidong Sun; Anu Sharma; Danae A Delivanis; Prabin Thapa; Ricky E Carter; Yogish C Kudva
Journal:  Diabetes Technol Ther       Date:  2017-10       Impact factor: 6.118

Review 8.  A critical review and analysis of ethical issues associated with the artificial pancreas.

Authors:  A Quintal; V Messier; R Rabasa-Lhoret; E Racine
Journal:  Diabetes Metab       Date:  2018-04-25       Impact factor: 6.041

Review 9.  The Case for Diabetes Population Health Improvement: Evidence-Based Programming for Population Outcomes in Diabetes.

Authors:  Sherita Hill Golden; Nisa Maruthur; Nestoras Mathioudakis; Elias Spanakis; Daniel Rubin; Mihail Zilbermint; Felicia Hill-Briggs
Journal:  Curr Diab Rep       Date:  2017-07       Impact factor: 4.810

10.  Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline.

Authors:  Rodolfo J Galindo; Guillermo E Umpierrez; Robert J Rushakoff; Ananda Basu; Suzanne Lohnes; James H Nichols; Elias K Spanakis; Juan Espinoza; Nadine E Palermo; Dessa Garnett Awadjie; Leigh Bak; Bruce Buckingham; Curtiss B Cook; Guido Freckmann; Lutz Heinemann; Roman Hovorka; Nestoras Mathioudakis; Tonya Newman; David N O'Neal; Michaela Rickert; David B Sacks; Jane Jeffrie Seley; Amisha Wallia; Trisha Shang; Jennifer Y Zhang; Julia Han; David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2020-09-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.