Literature DB >> 27830527

Effects of Different Waveforms on the Performance of Active Capillary Dielectric Barrier Discharge Ionization Mass Spectrometry.

Morphy C Dumlao1, Dan Xiao2, Daming Zhang2, John Fletcher2, William A Donald3.   

Abstract

Active capillary dielectric barrier discharge ionization (DBDI) is emerging as a compact, low-cost, and robust method to form intact ions of small molecules for detection in near real time by portable mass spectrometers. Here, we demonstrate that by using a 10 kHz, ~2.5 kVp-p high-voltage square-wave alternating current plasma, active capillary DBDI can consume less than 1 μW of power. In contrast, the power consumed using a sine and triangle alternating current waveform is more than two orders of magnitude higher than that for the square waveform to obtain a similar voltage for plasma generation. Moreover, the plasma obtained using a square waveform can be significantly more homogenous than that obtained using sine and triangle waveforms. Protonated dimethyl methylphosphonate (DMMP) and deprotonated perfluorooctanoic acid (PFOA) can be detected at about the same or higher abundances using square-wave DBDI mass spectrometry compared with the use of sine and triangle waveforms. By use of benzylammonium thermometer ions, the extent of internal energy deposition using square, sine, or triangle waveform excited plasmas are essentially the same at the optimum voltages for ion detection. Using an H-bridge circuit driving a transformer optimized to reduce losses, square-wave active capillary DBDI can be continuously powered for ~50 h by common 9 V-battery (PP3). Graphical Abstract ᅟ.

Entities:  

Keywords:  Chemical warfare agents; Dielectric barrier discharge ionization; Dimethyl methyl phosphonate; Low temperature plasma ionization; Nerve agents; Perfluorooctanoic acid; Persistent organic pollutants; Portable mass spectrometry; Thermometer ions

Year:  2016        PMID: 27830527     DOI: 10.1007/s13361-016-1535-5

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  13 in total

Review 1.  Desorption electrospray ionization and other ambient ionization methods: current progress and preview.

Authors:  Demian R Ifa; Chunping Wu; Zheng Ouyang; R Graham Cooks
Journal:  Analyst       Date:  2010-03-02       Impact factor: 4.616

2.  Active capillary plasma source for ambient mass spectrometry.

Authors:  Maryia M Nudnova; Liang Zhu; Renato Zenobi
Journal:  Rapid Commun Mass Spectrom       Date:  2012-06-30       Impact factor: 2.419

3.  Direct detection of explosives on solid surfaces by mass spectrometry with an ambient ion source based on dielectric barrier discharge.

Authors:  Na Na; Chao Zhang; Mengxia Zhao; Sichun Zhang; Chengdui Yang; Xiang Fang; Xinrong Zhang
Journal:  J Mass Spectrom       Date:  2007-08       Impact factor: 1.982

4.  Ambient sampling/ionization mass spectrometry: applications and current trends.

Authors:  Glenn A Harris; Asiri S Galhena; Facundo M Fernández
Journal:  Anal Chem       Date:  2011-05-06       Impact factor: 6.986

5.  Dielectric barrier discharges in analytical chemistry.

Authors:  C Meyer; S Müller; E L Gurevich; J Franzke
Journal:  Analyst       Date:  2011-05-12       Impact factor: 4.616

6.  Benzylammonium Thermometer Ions: Internal Energies of Ions Formed by Low Temperature Plasma and Atmospheric Pressure Chemical Ionization.

Authors:  Edward R Stephens; Morphy Dumlao; Dan Xiao; Daming Zhang; William A Donald
Journal:  J Am Soc Mass Spectrom       Date:  2015-10-05       Impact factor: 3.109

Review 7.  Ambient ionization mass spectrometry.

Authors:  Min-Zong Huang; Cheng-Hui Yuan; Sy-Chyi Cheng; Yi-Tzu Cho; Jentaie Shiea
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2010       Impact factor: 10.745

8.  Dielectric Barrier Discharge Ionization of Perfluorinated Compounds.

Authors:  Alexander Schütz; Sebastian Brandt; Sascha Liedtke; Daniel Foest; Ulrich Marggraf; Joachim Franzke
Journal:  Anal Chem       Date:  2015-11-05       Impact factor: 6.986

9.  Solid-phase microextraction low temperature plasma mass spectrometry for the direct and rapid analysis of chemical warfare simulants in complex mixtures.

Authors:  Morphy C Dumlao; Laura E Jeffress; J Justin Gooding; William A Donald
Journal:  Analyst       Date:  2016-03-18       Impact factor: 4.616

10.  Low-temperature plasma probe for ambient desorption ionization.

Authors:  Jason D Harper; Nicholas A Charipar; Christopher C Mulligan; Xinrong Zhang; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2008-12-01       Impact factor: 6.986

View more
  1 in total

1.  Degradation of the Neonicotinoid Pesticides in the Atmospheric Pressure Ionization Source.

Authors:  Yunfeng Chai; Hongping Chen; Xin Liu; Chengyin Lu
Journal:  J Am Soc Mass Spectrom       Date:  2017-12-19       Impact factor: 3.109

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.