Tear Deformation Time and optical quality in eyes wearing silicone hydrogel contact lenses.

Amir Asharlous1, Ebrahim Jafarzadehpur2, Ali Mirzajani3, Mehdi Khabazkhoob4, Samira Heydarian5, Ali Taghipour6.   

Abstract

PURPOSE: To evaluate tear film stability and optical aberrations in eyes wearing plano Lotrafilcon B contact lenses (CL).
METHODS: Tear Deformation Time (TDT) and aberrometric parameters were assessed in 86 normal emmetropic eyes before and 6 h after wearing CL. RESULT: A statistically significant decrease in TDT and increase in root mean square (RMS) values of higher order aberrations (HOA) were revealed 6 h after CL insertion (both P < 0.001). The low order aberrations (LOA) RMS values measured with CL were higher than those in naked eyes, but the difference was not statistically significant. None of individual Zernike polynomials showed any significant alteration.
CONCLUSION: Our findings indicated that the Lotrafilcon B contact lens affects HOA more than LOA. The tear film was less stable after wearing CL.

Entities:  

Keywords:  Aberrations; Optical quality; Silicone hydrogel contact lens; Tear Deformation Time; Tear stability

Year:  2016        PMID: 27830209      PMCID: PMC5093784          DOI: 10.1016/j.joco.2016.07.002

Source DB:  PubMed          Journal:  J Curr Ophthalmol        ISSN: 2452-2325


Introduction

Contact lenses (CL) are widely used to improve vision in eyes with refractive error. The corneal surface, however, may be affected by using the contact lens. Tear film stability time is an important measure of the quality of the tear film. The pre-lens tear stability is dependent on lens material characteristics, tear film properties, and lens–tear interaction. Our study attempts to address the effect of a silicone hydrogel contact lens, Lotrafilcon B, on tear film stability and optical aberrations of the eye.

Methods

Eighty-six eyes of 43 emmetropic subjects (refractive error within ±0.50) with a mean age of 19.55 ± 1.63 (range 18–23) years old comprised of 22 females and 18 males were entered in this study. Ethical clearance was obtained through the office of research ethics at Iran University of Medical Sciences. Refraction and keratometry for each subject was implemented by utilizing the Auto ref –keratometer. No ocular diseases or surface staining were seen in our volunteers. Low and higher order aberrations (HOA) were measured by using an objective aberrometer (HUVITZ, HRK 8000A, Korea). Root Mean Square (RMS) values of both low and HOA were calculated for 5.09 mm pupil sizes. Moreover, twelve Zernike coefficients were recorded. In addition, tear film stability was assessed for both eyes. To measure stability time, the non-invasive Tear Deformation Time (TDT) technique was applied.3, 4 After completing the aberrometry and TDT tests, a Plano powered silicone hydrogel contact lens (Air Optix Aqua, Lotrafilcon B, CIBA vision) was inserted into both right and left eyes. After 15 min elapsed to stabilize the lens on the cornea, fitting properties of the contact lens were evaluated. After achieving a good fit, the subjects were asked to stay 6 h with the lenses and perform their normal routine. Six hour after insertion of the contact lens, wave front aberrometry was repeated for their eyes. TDT was measured over the lens surface and recorded as Pre-Lens Tear Deformation Time (PL-TDT). At the end of these tests, CL were removed. Statistical analysis was performed using paired t test.

Results

Mean and standard deviation of the TDT and RMS values of low and HOA before and after contact lens insertion are summarized in Table 1.
Table 1

Mean and standard deviation (M ± SD) of the tear stability and aberrometric parameters for both right and left eyes in both naked and contact lens inserted status.

Right eye
Left eye
LOA (μm)HOA (μm)TDT (sec)LOA (μm)HOA (μm)TDT (sec)
Without CL0.195 ± 0.1340.148 ± 0.0959.82 ± 5.140.176 ± 0.1170.124 ± 0.0809.60 ± 4.58
With CL0.247 ± 0.1600.224 ± 0.1495.15 ± 2.340.204 ± 0.1120.170 ± 0.1285.08 ± 2.61
P value0.060.002<0.00010.080.003<0.0001

Tear Deformation Time (TDT); RMS (Root Mean Square); LOA (Low Order Aberrations); HOA (Higher Order Aberrations); μm (Micrometer); Sec (Seconds).

In all eyes, pre-lens TDT was significantly lower than the pre-corneal (before contact lens insertion) TDT (P < 0001). HOA-RMS values showed a significant increase after inserting the CL (P < 0.004). There were no significant changes in the other variables including LOA-RMS and individual 12 Zernike polynomials. The TDT results of the right eyes in both before and after lens wearing strongly correlated with data of the left eyes (Before: Pearson's r = 0.908, P < 0.0001/After: Pearson's r = 0.928, P < 0.0001).

Discussion

In good agreement with previous studies, our findings showed that the silicone hydrogel CL increase HOA in the optical system of the eye.5, 6 The variation of optical aberrations during the lens wear can be attributed to many factors, including lens centration relative to the corneal center, lens-to-cornea fitting relationship, optical quality of the contact lens, and pre-lens tear film status.7, 8 The first two factors were controlled as much as possible during the measurements. Optical quality was constant in all subjects because of selection of the plano CLs for this study. It seems the final factor, tear film dynamicity, played an important role in the alteration of the optical feature of the eye. It seems that the tear film on the contact lens surface is less stable than over the corneal surface. These findings have good consistency with previous studies.9, 10 Numerous studies have demonstrated that changing in tear film dynamicity and its break up can add optical aberrations and consequently, give rise to distorted retinal image quality.12, 13 Therefore, CL-induced tear instability can be an important factor to increase the wavefront aberrations.
  13 in total

1.  Differences in clinical parameters and tear film of tolerant and intolerant contact lens wearers.

Authors:  Melissa J Glasson; Fiona Stapleton; Lisa Keay; Deborah Sweeney; Mark D P Willcox
Journal:  Invest Ophthalmol Vis Sci       Date:  2003-12       Impact factor: 4.799

2.  Characteristics of the pre-lens tear film during hydrogel contact lens wear.

Authors:  G Young; N Efron
Journal:  Ophthalmic Physiol Opt       Date:  1991-01       Impact factor: 3.117

3.  The effect of short term contact lens wear on the tear film and ocular surface characteristics of tolerant and intolerant wearers.

Authors:  M J Glasson; F Stapleton; L Keay; M D P Willcox
Journal:  Cont Lens Anterior Eye       Date:  2006-02-23       Impact factor: 3.077

4.  Effect of hydrogel lens wear on tear film stability.

Authors:  E Faber; T R Golding; R Lowe; N A Brennan
Journal:  Optom Vis Sci       Date:  1991-05       Impact factor: 1.973

5.  [Optical performance of different soft contact lenses based on wavefront analysis].

Authors:  Roberta Fagnani Gatti; César Lipener
Journal:  Arq Bras Oftalmol       Date:  2008 Nov-Dec       Impact factor: 0.872

6.  Comparing tear film stability prolongation evaluated by Javal-Schiotz keratometer and slitlamp.

Authors:  Amir Asharlous; Ebrahim Jafarzadehpur; Ali Mirzajani; Mehdi Khabazkhoob
Journal:  Eye Contact Lens       Date:  2015-03       Impact factor: 2.018

7.  Age-related changes in precorneal tear film stability.

Authors:  S Patel; J C Farrell
Journal:  Optom Vis Sci       Date:  1989-03       Impact factor: 1.973

8.  Impaired functional visual acuity of dry eye patients.

Authors:  Eiki Goto; Yukiko Yagi; Yukihiro Matsumoto; Kazuo Tsubota
Journal:  Am J Ophthalmol       Date:  2002-02       Impact factor: 5.258

9.  Ocular fatigue is the major symptom of dry eye.

Authors:  I Toda; H Fujishima; K Tsubota
Journal:  Acta Ophthalmol (Copenh)       Date:  1993-06

10.  Objective and subjective assessing efficacy of a lubricating drop in eyes wearing silicone hydrogel contact lenses.

Authors:  Amir Asharlous; Ali Mirzajani; Ebrahim Jafarzadehpur; Mehdi KhabazKhoob; Hadi Ostadimoghaddam
Journal:  J Curr Ophthalmol       Date:  2016-05-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.