Literature DB >> 16497539

The effect of short term contact lens wear on the tear film and ocular surface characteristics of tolerant and intolerant wearers.

M J Glasson1, F Stapleton, L Keay, M D P Willcox.   

Abstract

The purpose of this study was to determine the effect of contact lens wear on the tear film and ocular surface of people tolerant or intolerant to contact lens wear. Twenty subjects participated; 11 tolerants and nine intolerants. Their baseline tear film (no lens wear) was analysed with a range of clinical measurements and protein analyses (lactoferrin, sIgA and lysozyme). The tests were then repeated at the end of 6h of contact lens wear during the day and while lenses were worn. Both tolerants and intolerants showed statistically significant increases in bulbar and overall conjunctival redness after 6h of lens wear. For tolerants only, there was a statistically significant increase in the tear film meniscus area (0.08 mm(2) +/- 0.04 compared to 0.14 mm(2) +/- 0.06 (p = 0.023)) and a statistically significant decrease in the non-invasive tear film break-up time (NI-TBUT; 21.3 s +/- 5.7 compared to 3.7 s +/- 4.3 (p = 0.003)) after 6h of lens wear. There were no changes in other tear film or ocular surface parameters. The protein concentration and lipid layer appearance did not change during lens wear for either population. Prior to lens wear, tolerant subjects had a statistically longer NI-TBUT, higher phenol red thread test and higher tear flow rate. After 6h of lens wear and while wearing lenses, all but NI-TBUT remained statistically different. Lens wear affected only a small number of clinical variables and 6h wear did not effect the concentration of those proteins measured in tears in this study.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16497539     DOI: 10.1016/j.clae.2005.12.006

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  12 in total

1.  Simulation of the hydrodynamic conditions of the eye to better reproduce the drug release from hydrogel contact lenses: experiments and modeling.

Authors:  A F R Pimenta; A Valente; J M C Pereira; J C F Pereira; H P Filipe; J L G Mata; R Colaço; B Saramago; A P Serro
Journal:  Drug Deliv Transl Res       Date:  2016-12       Impact factor: 4.617

2.  Intolerant contact lens wearers exhibit ocular surface impairment despite 3 months wear discontinuation.

Authors:  Giuseppe Giannaccare; William Blalock; Michela Fresina; Aldo Vagge; Piera Versura
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-06-09       Impact factor: 3.117

3.  Controlled release of high molecular weight hyaluronic Acid from molecularly imprinted hydrogel contact lenses.

Authors:  Maryam Ali; Mark E Byrne
Journal:  Pharm Res       Date:  2009-01-21       Impact factor: 4.200

4.  In vivo drug delivery via contact lenses: The current state of the field from origins to present.

Authors:  Liana D Wuchte; Stephen A DiPasquale; Mark E Byrne
Journal:  J Drug Deliv Sci Technol       Date:  2021-02-18       Impact factor: 5.062

5.  Tear Deformation Time and optical quality in eyes wearing silicone hydrogel contact lenses.

Authors:  Amir Asharlous; Ebrahim Jafarzadehpur; Ali Mirzajani; Mehdi Khabazkhoob; Samira Heydarian; Ali Taghipour
Journal:  J Curr Ophthalmol       Date:  2016-07-25

6.  Proteomics Unravels the Regulatory Mechanisms in Human Tears Following Acute Renouncement of Contact Lens Use: A Comparison between Hard and Soft Lenses.

Authors:  Caroline Manicam; Natarajan Perumal; Joanna Wasielica-Poslednik; Yong Cajetan Ngongkole; Alexandra Tschäbunin; Marcel Sievers; Walter Lisch; Norbert Pfeiffer; Franz H Grus; Adrian Gericke
Journal:  Sci Rep       Date:  2018-08-01       Impact factor: 4.379

7.  Effect of Three Interventions on Contact Lens Comfort in Symptomatic Wearers: A Randomized Clinical Trial.

Authors:  Maria Navascues-Cornago; Philip B Morgan; Carole Maldonado-Codina
Journal:  PLoS One       Date:  2015-08-12       Impact factor: 3.240

8.  Objective and subjective assessing efficacy of a lubricating drop in eyes wearing silicone hydrogel contact lenses.

Authors:  Amir Asharlous; Ali Mirzajani; Ebrahim Jafarzadehpur; Mehdi KhabazKhoob; Hadi Ostadimoghaddam
Journal:  J Curr Ophthalmol       Date:  2016-05-24

9.  This issue at a glance.

Authors: 
Journal:  J Curr Ophthalmol       Date:  2016-06-10

10.  Influence of Sodium Hyaluronate Concentration on Corneal Aberrations in Soft Contact Lens Wearers.

Authors:  Jong Soo Lee; Jong Moon Park; Hyun Kyung Cho; Su Jin Kim; Hyoun Do Huh; Young Min Park
Journal:  Korean J Ophthalmol       Date:  2018-03-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.