Literature DB >> 27822890

Comparison of the endothelial coverage in everolimus and zotarolimus-eluting stents in normal, atherosclerotic, and bifurcation rabbit iliac arteries.

Sho Torii1, Gaku Nakazawa2, Takeshi Ijichi1, Ayako Yoshikawa1, Yohei Ohno1, Yuji Ikari1.   

Abstract

The aim of this study is to evaluate differences in stent endothelial coverage among the second generation of drug-eluting stents. Incomplete stent coverage is one of the major causes of late stent thrombosis. Rabbits fed a normal diet received an everolimus (Xience Prime; EES) and a zotarolimus-eluting stent (Resolute Integrity; R-ZES) in each iliac artery, followed by sacrifice at 14 and 28 days after stent implantation. In addition, a group of atherosclerotic rabbits similarly received EES and R-ZES, and were sacrificed at 28 days. The extent of stent endothelial coverage was assessed by scanning electron microscopy. To evaluate endothelial coverage after bifurcation stenting, rabbits received EES and R-ZES placed with culotte stenting at the iliac bifurcation, followed by sacrifice at 14 and 28 days. In rabbits fed a normal diet, the percent uncovered strut area 14 days after stent implantation was significantly higher in R-ZES than in EES (10.1% (IQR 9.8-15.5) vs. 3.0% (IQR 1.5-9.7), p = 0.03), whereas it was not significantly different at 28-days (3.9% (IQR 0.8-10.3) vs. 1.0% (IQR 0.0-2.8), p = 0.2). In rabbits with induced atheroma, R-ZES also showed less endothelial coverage 28 days after stent implantation (5.3% (IQR 2.2-9.9) vs. 1.1% (IQR 0-6.2), p = 0.03). In the culotte stenting model, the percent uncovered strut area of the proximal overlapped segment was significantly higher in R-ZES at 14 days (15.8% (IQR 14.3-17.7) vs. 8.8% (IQR 8.3-9.8), p = 0.03) and 28 days (9.9% (IQR 4.1-13.9) vs. 2.5% (IQR 1.6-6.7), p = 0.04) after stent implantation. The carina area also showed a better coverage in EES compared with R-ZES. EES showed a better stent endothelial coverage compared with R-ZES after stent implantation in the early phase in normals, in arteries with lipid rich plaque, and in bifurcation stented sites.

Entities:  

Keywords:  Carina; Culottes stenting; EES; Endothelial coverage; R-ZES; Resolute integrity; Xience Prime

Mesh:

Substances:

Year:  2016        PMID: 27822890     DOI: 10.1007/s12928-016-0437-6

Source DB:  PubMed          Journal:  Cardiovasc Interv Ther        ISSN: 1868-4297


  3 in total

1.  Stability and bioactivity of pepCD47 attachment on stainless steel surfaces.

Authors:  Vaishali V Inamdar; Emmett Fitzpatrick; Ivan Alferiev; Chandrasekaran Nagaswami; Lynn A Spruce; Hossein Fazelinia; George Bratinov; Steven H Seeholzer; Robert J Levy; Ilia Fishbein; Stanley J Stachelek
Journal:  Acta Biomater       Date:  2020-01-11       Impact factor: 8.947

Review 2.  Drug-eluting coronary stents: insights from preclinical and pathology studies.

Authors:  Sho Torii; Hiroyuki Jinnouchi; Atsushi Sakamoto; Matthew Kutyna; Anne Cornelissen; Salome Kuntz; Liang Guo; Hiroyoshi Mori; Emanuel Harari; Ka Hyun Paek; Raquel Fernandez; Diljon Chahal; Maria E Romero; Frank D Kolodgie; Anuj Gupta; Renu Virmani; Aloke V Finn
Journal:  Nat Rev Cardiol       Date:  2019-07-25       Impact factor: 32.419

3.  Antiplatelet Effect of Single Antiplatelet Therapy With Prasugrel and Oral Anticoagulation After Stent Implantation in a Rabbit Arteriovenous Shunt Model.

Authors:  Sho Torii; Tadashi Yamamoto; Norihito Nakamura; Takeshi Ijichi; Ayako Yoshikawa; Yusuke Ito; Atsuhiro Sugidachi; Yuji Ikari; Gaku Nakazawa
Journal:  Circ Rep       Date:  2021-08-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.