Literature DB >> 27819253

IPEM topical report 1: guidance on implementing flattening filter free (FFF) radiotherapy.

Geoff Budgell1, Kirstie Brown, Jason Cashmore, Simon Duane, John Frame, Mark Hardy, David Paynter, Russell Thomas.   

Abstract

Flattening filter free (FFF) beams are now commonly available with new standard linear accelerators. These beams have recognised clinical advantages in certain circumstances, most notably the reduced beam-on times for high dose per fraction stereotactic treatments. Therefore FFF techniques are quickly being introduced into clinical use. The purpose of this report is to provide practical implementation advice and references for centres implementing FFF beams clinically. In particular UK-specific guidance is given for reference dosimetry and radiation protection.

Entities:  

Mesh:

Year:  2016        PMID: 27819253     DOI: 10.1088/0031-9155/61/23/8360

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Using FFF Beams to Improve the Therapeutic Ratio of Lung SBRT.

Authors:  Oleg N Vassiliev; Christine B Peterson; Joe Y Chang; Radhe Mohan
Journal:  J Radiother Pract       Date:  2020-07-30

2.  A proposed method for linear accelerator photon beam steering using EPID.

Authors:  Michael P Barnes; Frederick W Menk; Bishnu P Lamichhane; Peter B Greer
Journal:  J Appl Clin Med Phys       Date:  2018-07-26       Impact factor: 2.102

3.  Enhancement of the Dose on 12 MV Linac with Free Flattening Filter Mode.

Authors:  Zeghari A; Saaidi R; Cherkaoui El Moursli R
Journal:  J Biomed Phys Eng       Date:  2019-08-01

4.  Surface and build-up dose comparison between Elekta 6 MV flattening filter and flattening-filter-free beams using an advanced Markus ionization chamber and a solid water-equivalent phantom.

Authors:  Toshikazu Imae; Shigeharu Takenaka; Yuichi Watanabe; Atsushi Aoki; Kanako Matsuda; Katsutake Sasaki; Shigeki Saegusa; Kanabu Nawa; Keiichi Nakagawa; Osamu Abe
Journal:  J Appl Clin Med Phys       Date:  2020-11-12       Impact factor: 2.102

5.  Consistency of small-field dosimetry, on and off axis, in beam-matched linacs used for stereotactic radiosurgery.

Authors:  Luis Muñoz; Tomas Kron; Marco Petasecca; Joseph Bucci; Michael Jackson; Peter Metcalfe; Anatoly B Rosenfeld; Giordano Biasi
Journal:  J Appl Clin Med Phys       Date:  2021-01-13       Impact factor: 2.102

6.  Commissioning measurements on an Elekta Unity MR-Linac.

Authors:  Marcus Powers; John Baines; Robert Crane; Chantelle Fisher; Stephen Gibson; Linda Marsh; Bronwyn Oar; Ariadne Shoobridge; Emily Simpson-Page; Marchant Van der Walt; Glenn de Vine
Journal:  Phys Eng Sci Med       Date:  2022-03-02

7.  Choice of a Suitable Dosimeter for Photon Percentage Depth Dose Measurements in Flattening Filter-Free Beams.

Authors:  Silvia Vargas Castrillón; Francisco Cutanda Henríquez
Journal:  J Med Phys       Date:  2017 Jul-Sep

8.  CyberKnife® fixed cone and Iris™ defined small radiation fields: Assessment with a high-resolution solid-state detector array.

Authors:  Giordano Biasi; Marco Petasecca; Susanna Guatelli; Ebert A Martin; Garry Grogan; Benjamin Hug; Jonathan Lane; Vladimir Perevertaylo; Tomas Kron; Anatoly B Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2018-07-12       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.