Literature DB >> 27818105

Role of continuous glucose monitoring for type 2 in diabetes management and research.

Robert Vigersky1, Maneesh Shrivastav2.   

Abstract

The advent of continuous glucose monitoring (CGM) is a significant stride forward in our ability to better understand the glycemic status of our patients. Current clinical practice employs two forms of CGM: professional (retrospective or "masked") and personal (real-time) to evaluate and/or monitor glycemic control. Most studies using professional and personal CGM have been done in those with type 1 diabetes (T1D). However, this technology is agnostic to the type of diabetes and can also be used in those with type 2 diabetes (T2D). The value of professional CGM in T2D for physicians, patients, and researchers is derived from its ability to: (1) to discover previously unknown hyper- and hypoglycemia (silent and symptomatic); (2) measure glycemic control directly rather than through the surrogate metric of hemoglobin A1C (HbA1C) permitting the observation of a wide variety of metrics that include glycemic variability, the percent of time within, below and above target glucose levels, the severity of hypo- and hyperglycemia throughout the day and night; (3) provide actionable information for healthcare providers derived by the CGM report; (4) better manage patients on hemodialysis; and (5) effectively and efficiently analyze glycemic effects of new interventions whether they be pharmaceuticals (duration of action, pharmacodynamics, safety, and efficacy), devices, or psycho-educational. Personal CGM has also been successfully used in a small number of studies as a behavior modification tool in those with T2D. This comprehensive review describes the differences between professional and personal CGM and the evidence for the use of each form of CGM in T2D. Finally, the opinions of key professional societies on the use of CGM in T2D are presented.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Continuous glucose monitoring; Diabetes management; Glycemic control; Hypoglycemia; Type 2 diabetes mellitus

Mesh:

Substances:

Year:  2016        PMID: 27818105     DOI: 10.1016/j.jdiacomp.2016.10.007

Source DB:  PubMed          Journal:  J Diabetes Complications        ISSN: 1056-8727            Impact factor:   2.852


  31 in total

Review 1.  Closing the Loop.

Authors:  Revital Nimri; Nathan Murray; Alexander Ochs; Jordan E Pinsker; Eyal Dassau
Journal:  Diabetes Technol Ther       Date:  2017-02       Impact factor: 6.118

2.  Diabetes and Prediabetes Classification Using Glycemic Variability Indices From Continuous Glucose Monitoring Data.

Authors:  Giada Acciaroli; Giovanni Sparacino; Liisa Hakaste; Andrea Facchinetti; Giorgio Maria Di Nunzio; Alessandro Palombit; Tiinamaija Tuomi; Rafael Gabriel; Jaime Aranda; Saturio Vega; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2017-06-01

Review 3.  Role of Continuous Glucose Monitoring in Clinical Trials: Recommendations on Reporting.

Authors:  Oliver Schnell; Katharine Barnard; Richard Bergenstal; Emanuele Bosi; Satish Garg; Bruno Guerci; Thomas Haak; Irl B Hirsch; Linong Ji; Shashank R Joshi; Maarten Kamp; Lori Laffel; Chantal Mathieu; William H Polonsky; Frank Snoek; Philip Home
Journal:  Diabetes Technol Ther       Date:  2017-05-22       Impact factor: 6.118

4.  Continuous Glucose Monitoring: Current Use in Diabetes Management and Possible Future Applications.

Authors:  Martina Vettoretti; Giacomo Cappon; Giada Acciaroli; Andrea Facchinetti; Giovanni Sparacino
Journal:  J Diabetes Sci Technol       Date:  2018-05-22

Review 5.  Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.

Authors:  David Rodbard
Journal:  Diabetes Technol Ther       Date:  2017-06       Impact factor: 6.118

Review 6.  Continuous Glucose Monitoring with Multiple Daily Insulin Treatment: Outcome Studies.

Authors:  Janet B McGill; Andrew Ahmann
Journal:  Diabetes Technol Ther       Date:  2017-06       Impact factor: 6.118

Review 7.  How Can We Realize the Clinical Benefits of Continuous Glucose Monitoring?

Authors:  Ramzi A Ajjan
Journal:  Diabetes Technol Ther       Date:  2017-05       Impact factor: 6.118

Review 8.  Clinical Use of Continuous Glucose Monitoring in Adults with Type 2 Diabetes.

Authors:  Anders L Carlson; Deborah M Mullen; Richard M Bergenstal
Journal:  Diabetes Technol Ther       Date:  2017-05       Impact factor: 6.118

Review 9.  Use of Continuous Glucose Monitoring in Youth-Onset Type 2 Diabetes.

Authors:  Christine L Chan
Journal:  Curr Diab Rep       Date:  2017-09       Impact factor: 4.810

Review 10.  Continuous Glucose Monitoring Integration in Clinical Practice: A Stepped Guide to Data Review and Interpretation.

Authors:  Grazia Aleppo; Kimberly Webb
Journal:  J Diabetes Sci Technol       Date:  2018-11-19
View more