Literature DB >> 27783125

Chemiluminescence lateral flow immunoassay cartridge with integrated amorphous silicon photosensors array for human serum albumin detection in urine samples.

Martina Zangheri1, Fabio Di Nardo2, Mara Mirasoli3,4, Laura Anfossi2, Augusto Nascetti5, Domenico Caputo6, Giampiero De Cesare6, Massimo Guardigli1, Claudio Baggiani2, Aldo Roda1,7.   

Abstract

A novel and disposable cartridge for chemiluminescent (CL)-lateral flow immunoassay (LFIA) with integrated amorphous silicon (a-Si:H) photosensors array was developed and applied to quantitatively detect human serum albumin (HSA) in urine samples. The presented analytical method is based on an indirect competitive immunoassay using horseradish peroxidase (HRP) as a tracer, which is detected by adding the luminol/enhancer/hydrogen peroxide CL cocktail. The system comprises an array of a-Si:H photosensors deposited on a glass substrate, on which a PDMS cartridge that houses the LFIA strip and the reagents necessary for the CL immunoassay was optically coupled to obtain an integrated analytical device controlled by a portable read-out electronics. The method is simple and fast with a detection limit of 2.5 mg L-1 for HSA in urine and a dynamic range up to 850 mg L-1, which is suitable for measuring physiological levels of HSA in urine samples and their variation in different diseases (micro- and macroalbuminuria). The use of CL detection allowed accurate and objective analyte quantification in a dynamic range that extends from femtomoles to picomoles. The analytical performances of this integrated device were found to be comparable with those obtained using a charge-coupled device (CCD) as a reference off-chip detector. These results demonstrate that integrating the a-Si:H photosensors array with CL-LFIA technique provides compact, sensitive and low-cost systems for CL-based bioassays with a wide range of applications for in-field and point-of-care bioanalyses. Graphical Abstract A novel integrated portable device was developed for direct quantitative detection of human serum albumin (HSA) in urine samples, exploiting a chemiluminescence lateral flow immunoassay (LFIA). The device comprises a cartridge that holds the LFIA strip and all the reagents necessary for the analysis, an array of amorphous silicon photosensors, and a custom read-out electronics.

Entities:  

Keywords:  Albuminuria; Amorphous hydrogenated silicon photosensors; Biosensors; Chemiluminescence; Integrated microdevice; Lateral flow immunoassay

Mesh:

Substances:

Year:  2016        PMID: 27783125     DOI: 10.1007/s00216-016-9991-0

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  10 in total

Review 1.  Current and emerging trends in point-of-care urinalysis tests.

Authors:  Rongwei Lei; Rannon Huo; Chandra Mohan
Journal:  Expert Rev Mol Diagn       Date:  2019-12-12       Impact factor: 5.225

Review 2.  Construction and Potential Applications of Biosensors for Proteins in Clinical Laboratory Diagnosis.

Authors:  Xuan Liu; Hui Jiang
Journal:  Sensors (Basel)       Date:  2017-12-04       Impact factor: 3.576

3.  Fully electronic urine dipstick probe for combinatorial detection of inflammatory biomarkers.

Authors:  Vikramshankar Kamakoti; David Kinnamon; Kang Hyeok Choi; Badrinath Jagannath; Shalini Prasad
Journal:  Future Sci OA       Date:  2018-03-27

Review 4.  Chemiluminescence and Bioluminescence Imaging for Biosensing and Therapy: In Vitro and In Vivo Perspectives.

Authors:  Yongcun Yan; Pengfei Shi; Weiling Song; Sai Bi
Journal:  Theranostics       Date:  2019-05-31       Impact factor: 11.556

5.  Analyte Quantity Detection from Lateral Flow Assay Using a Smartphone.

Authors:  Kamrul H Foysal; Sung Eun Seo; Min Ju Kim; Oh Seok Kwon; Jo Woon Chong
Journal:  Sensors (Basel)       Date:  2019-11-05       Impact factor: 3.576

Review 6.  Review: Detection and quantification of proteins in human urine.

Authors:  Sultan Aitekenov; Abduzhappar Gaipov; Rostislav Bukasov
Journal:  Talanta       Date:  2020-10-14       Impact factor: 6.057

7.  On-Glass Integrated SU-8 Waveguide and Amorphous Silicon Photosensor for On-Chip Detection of Biomolecules: Feasibility Study on Hemoglobin Sensing.

Authors:  Alessio Buzzin; Rita Asquini; Domenico Caputo; Giampiero de Cesare
Journal:  Sensors (Basel)       Date:  2021-01-08       Impact factor: 3.576

Review 8.  Monoclonal Antibodies Application in Lateral Flow Immunochromatographic Assays for Drugs of Abuse Detection.

Authors:  Zidane Qriouet; Yahia Cherrah; Hassan Sefrioui; Zineb Qmichou
Journal:  Molecules       Date:  2021-02-18       Impact factor: 4.411

Review 9.  Recent Advancements in Enzyme-Based Lateral Flow Immunoassays.

Authors:  Donato Calabria; Maria Maddalena Calabretta; Martina Zangheri; Elisa Marchegiani; Ilaria Trozzi; Massimo Guardigli; Elisa Michelini; Fabio Di Nardo; Laura Anfossi; Claudio Baggiani; Mara Mirasoli
Journal:  Sensors (Basel)       Date:  2021-05-12       Impact factor: 3.576

Review 10.  Paper-Based Immunosensors with Bio-Chemiluminescence Detection.

Authors:  Maria Maddalena Calabretta; Martina Zangheri; Donato Calabria; Antonia Lopreside; Laura Montali; Elisa Marchegiani; Ilaria Trozzi; Massimo Guardigli; Mara Mirasoli; Elisa Michelini
Journal:  Sensors (Basel)       Date:  2021-06-24       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.