Literature DB >> 27770609

In vivo six-degree-of-freedom knee-joint kinematics in overground and treadmill walking following total knee arthroplasty.

Shanyuanye Guan1, Hans A Gray1, Anthony G Schache1, Julian Feller2, Richard de Steiger3, Marcus G Pandy1.   

Abstract

No data are available to describe six-degree-of-freedom (6-DOF) knee-joint kinematics for one complete cycle of overground walking following total knee arthroplasty (TKA). The aims of this study were firstly, to measure 6-DOF knee-joint kinematics and condylar motion for overground walking following TKA; and secondly, to determine whether such data differed between overground and treadmill gait when participants walked at the same speed during both tasks. A unique mobile biplane X-ray imaging system enabled accurate measurement of 6-DOF TKA knee kinematics during overground walking by simultaneously tracking and imaging the joint. The largest rotations occurred for flexion-extension and internal-external rotation whereas the largest translations were associated with joint distraction and anterior-posterior drawer. Strong associations were found between flexion-extension and adduction-abduction (R2  = 0.92), joint distraction (R2  = 1.00), and anterior-posterior translation (R2  = 0.77), providing evidence of kinematic coupling in the TKA knee. Although the measured kinematic profiles for overground walking were grossly similar to those for treadmill walking, several statistically significant differences were observed between the two conditions with respect to temporo-spatial parameters, 6-DOF knee-joint kinematics, and condylar contact locations and sliding. Thus, caution is advised when making recommendations regarding knee implant performance based on treadmill-measured knee-joint kinematic data.
© 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1634-1643, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  biplane X-ray fluoroscopy; gait; implant wear; joint loading; joint replacement

Mesh:

Year:  2016        PMID: 27770609     DOI: 10.1002/jor.23466

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  7 in total

1.  Tibiofemoral helical axis of motion during the full gait cycle measured using biplane radiography.

Authors:  Tom Gale; William Anderst
Journal:  Med Eng Phys       Date:  2020-10-28       Impact factor: 2.242

2.  Medial congruent polyethylene design show different tibiofemoral kinematics and enhanced congruency compared to a standard symmetrical cruciate retaining design for total knee arthroplasty-an in vivo randomized controlled study of gait using dynamic radiostereometry.

Authors:  Emil Toft Petersen; Søren Rytter; Daan Koppens; Jesper Dalsgaard; Torben Bæk Hansen; Michael Skipper Andersen; Maiken Stilling
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-07-09       Impact factor: 4.342

3.  Knee implant kinematics are task-dependent.

Authors:  Pascal Schütz; Barbara Postolka; Hans Gerber; Stephen J Ferguson; William R Taylor; Renate List
Journal:  J R Soc Interface       Date:  2019-02-28       Impact factor: 4.118

4.  Kinematic Evaluation of the GMK Sphere Implant During Gait Activities: A Dynamic Videofluoroscopy Study.

Authors:  Pascal Schütz; William R Taylor; Barbara Postolka; Sandro F Fucentese; Peter P Koch; Michael A R Freeman; Vera Pinskerova; Renate List
Journal:  J Orthop Res       Date:  2019-08-07       Impact factor: 3.494

5.  The relationship between alignment, function and loading in total knee replacement: In-vivo analysis of a unique patient population.

Authors:  David Williams; Andrew Metcalfe; June Madete; Gemma Whatling; Peter Kempshall; Mark Forster; Kathleen Lyons; Cathy Holt
Journal:  J Biomech       Date:  2020-09-11       Impact factor: 2.712

6.  Influence of the moving fluoroscope on gait patterns.

Authors:  Marina Hitz; Pascal Schütz; Michael Angst; William R Taylor; Renate List
Journal:  PLoS One       Date:  2018-07-13       Impact factor: 3.240

7.  Elongation Patterns of the Collateral Ligaments After Total Knee Arthroplasty Are Dominated by the Knee Flexion Angle.

Authors:  Seyyed Hamed Hosseini Nasab; Colin R Smith; Pascal Schütz; Barbara Postolka; Renate List; William R Taylor
Journal:  Front Bioeng Biotechnol       Date:  2019-11-12
  7 in total