Rapid detection of bacterial endotoxins in ophthalmic viscosurgical device materials by direct analysis in real time mass spectrometry.

Hongli Li1, Victoria M Hitchins2, Samanthi Wickramasekara3.   

Abstract

Bacterial endotoxins are lipopolysaccharides bound to the bacterial cell wall and released when bacteria rupture or disintegrate. Possible contamination of endotoxin in ophthalmic devices can cause a painful eye inflammation or result in toxic anterior segment syndrome after cataract surgery. Measurement of bacterial endotoxin in medical device materials is difficult since endotoxin binds with polymer matrix and some of the materials are very viscous and non-water soluble, where traditional enzyme-based Limulus amebocyte lysate (LAL) assay cannot be applied. Here we propose a rapid and high throughput ambient ionization mass spectrometric (MS) method using direct analysis in real time (DART) for the evaluation of endotoxin contamination in medical device materials. Large and structurally complex endotoxin instantaneously breaks down into low-mass characteristic fragment ions using DART and is detected by MS in both positive and negative ion modes. This method enables the identification and separation of endotoxin from medical materials with a detection limit of 0.03 ng mL-1 endotoxins in aqueous solution. Ophthalmic viscosurgical device materials including sodium hyaluronate (NaHA), non-water soluble perfluoro-n-octane (PFO) and silicone oil (SO) were spiked with different known concentrations of endotoxin and analyzed by DART MS, where the presence of endotoxin was successfully detected and featured small mass fragment ions were generated for NaHA, PFO and SO as well. Current findings showed the feasibility of measuring endotoxin contamination in medical device materials using DART-MS, which can lead to a one-step analysis of endotoxins in different matrices, avoiding any potential contamination during sample pre-treatment steps. Published by Elsevier B.V.

Entities:  

Keywords:  Direct analysis in real time; Endotoxin; Mass spectrometry; Perfluoro-n-octane; Silicone oil; Sodium hyaluronate

Mesh:

Substances:

Year:  2016        PMID: 27769383      PMCID: PMC5500980          DOI: 10.1016/j.aca.2016.09.030

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  53 in total

1.  Direct microextraction and analysis of rough-type lipopolysaccharides by combined thin-layer chromatography and MALDI mass spectrometry.

Authors:  H Therisod; V Labas; M Caroff
Journal:  Anal Chem       Date:  2001-08-15       Impact factor: 6.986

2.  Silicone oil bubbles in ophthalmic viscosurgical devices.

Authors:  Ines M Lanzl; Ralph Laurent Merté
Journal:  J Cataract Refract Surg       Date:  2002-12       Impact factor: 3.351

3.  Endotoxin contamination in the dental surgery.

Authors:  M K Huntington; J F Williams; C D Mackenzie
Journal:  J Med Microbiol       Date:  2007-09       Impact factor: 2.472

4.  Endotoxin contamination delays the foreign body reaction.

Authors:  Sander M van Putten; Maike Wübben; Josée A Plantinga; Wim E Hennink; Marja J A van Luyn; Martin C Harmsen
Journal:  J Biomed Mater Res A       Date:  2011-06-16       Impact factor: 4.396

5.  Outbreak of toxic anterior segment syndrome associated with glutaraldehyde after cataract surgery.

Authors:  Mustafa Unal; Iclal Yücel; Yusuf Akar; Asli Oner; Meryem Altin
Journal:  J Cataract Refract Surg       Date:  2006-10       Impact factor: 3.351

6.  The Limulus amebocyte lysate assay. A rapid and sensitive method for diagnosing early gram-negative peritonitis in patients undergoing continuous ambulatory peritoneal dialysis.

Authors:  M D Clayman; A Raymond; D Colen; C Moffitt; C Wolf; E G Neilson
Journal:  Arch Intern Med       Date:  1987-02

7.  Nuclear magnetic resonance analysis of emulsified silicone oil RMN-3 (Oxane HD).

Authors:  Paul J Tomlins; Malcolm G L Woodcock; Neil Spencer; Graham R Kirkby
Journal:  Br J Ophthalmol       Date:  2007-04-12       Impact factor: 4.638

8.  Optimization of direct analysis in real time (DART) linear ion trap parameters for the detection and quantitation of glucose.

Authors:  Daudi S Saang'onyo; Darrin L Smith
Journal:  Rapid Commun Mass Spectrom       Date:  2012-02-15       Impact factor: 2.419

9.  Forensic Analysis of Human Autopsy Tissue for the Presence of Polydimethylsiloxane (Silicone) and Volatile Cyclic Siloxanes using Macro FT-IR, FT-IR Spectroscopic Imaging and Headspace GC-MS.

Authors:  Adam Lanzarotta; Caroline Machal Kelley
Journal:  J Forensic Sci       Date:  2016-01-06       Impact factor: 1.832

Review 10.  Lipopolysaccharide: Biosynthetic pathway and structure modification.

Authors:  Xiaoyuan Wang; Peter J Quinn
Journal:  Prog Lipid Res       Date:  2009-10-06       Impact factor: 16.195

View more
  4 in total

1.  The Ion Source of Nitrogen Direct Analysis in Real-Time Mass Spectrometry as a Highly Efficient Reactor: Generation of Reactive Oxygen Species.

Authors:  Rui Su; Wenjing Yu; Kaiju Sun; Jie Yang; Changbao Chen; Wenhui Lian; Shuying Liu; Hongmei Yang
Journal:  J Am Soc Mass Spectrom       Date:  2019-02-19       Impact factor: 3.109

Review 2.  Clinical Chemistry for Developing Countries: Mass Spectrometry.

Authors:  Suji Lee; Kavyasree Chintalapudi; Abraham K Badu-Tawiah
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2021-07-27       Impact factor: 10.745

3.  A New Strategy Involving the Use of Peptides and Graphene Oxide for Fluorescence Turn-on Detection of Proteins.

Authors:  Huan Shi; Bibo Zhang; Shuwen Liu; Chunyan Tan; Ying Tan; Yuyang Jiang
Journal:  Sensors (Basel)       Date:  2018-01-29       Impact factor: 3.576

4.  Novel SH-SAW Biosensors for Ultra-Fast Recognition of Growth Factors.

Authors:  Daniel Matatagui; Ágatha Bastida; M Carmen Horrillo
Journal:  Biosensors (Basel)       Date:  2021-12-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.