Literature DB >> 17761488

Endotoxin contamination in the dental surgery.

M K Huntington1, J F Williams1, C D Mackenzie2.   

Abstract

Dental waterlines contain large numbers of Gram-negative bacteria. Endotoxin, a component of such organisms, has significant health implications. Paired samples of dental unit water and the aerosols generated during dental procedures were collected, and assayed for bacteria and endotoxin levels, using heterotrophic plate counts and the Limulus amoebocyte lysate test. Consistent with published studies, the extent of bacterial contamination in the dental waters sampled for this investigation surpassed the levels associated with potable water, with counts in excess of 2.0x10(6) c.f.u. ml(-1) in some samples. Correspondingly high concentrations of endotoxin [up to 15 000 endotoxin units (EU) ml(-1)] were present in the water. A statistically significant Spearman correlation coefficient of rho=0.94 between endotoxin (EU ml(-1)) and bacterial load (c.f.u. ml(-1)) was demonstrated. All of the aerosol samples contained detectable endotoxin. Further studies of the consequences of dental endotoxin exposure, and evaluation of means to prevent exposure, are warranted.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17761488     DOI: 10.1099/jmm.0.47231-0

Source DB:  PubMed          Journal:  J Med Microbiol        ISSN: 0022-2615            Impact factor:   2.472


  7 in total

1.  Workplace determinants of endotoxin exposure in dental healthcare facilities in South Africa.

Authors:  Tanusha S Singh; Braimoh Bello; Onnicah D Mabe; Kevin Renton; Mohamed F Jeebhay
Journal:  Ann Occup Hyg       Date:  2009-12-31

2.  Risk factors associated with asthma phenotypes in dental healthcare workers.

Authors:  Tanusha Singh; Braimoh Bello; Mohamed F Jeebhay
Journal:  Am J Ind Med       Date:  2012-04-02       Impact factor: 2.214

3.  Rapid detection of bacterial endotoxins in ophthalmic viscosurgical device materials by direct analysis in real time mass spectrometry.

Authors:  Hongli Li; Victoria M Hitchins; Samanthi Wickramasekara
Journal:  Anal Chim Acta       Date:  2016-09-29       Impact factor: 6.558

4.  Evaluation of 3 dental unit waterline contamination testing methods.

Authors:  Nuala Porteous; Yuyu Sun; John Schoolfield
Journal:  Gen Dent       Date:  2015 Jan-Feb

5.  Assessment of nosocomial bacterial contamination in dental unit waterlines: Impact of flushing.

Authors:  Manal M Alkhulaifi; Dalal H Alotaibi; Hisham Alajlan; Thekra Binshoail
Journal:  Saudi Dent J       Date:  2019-07-19

6.  Characterizing Inflammatory Cell Asthma Associated Phenotypes in Dental Health Workers Using Cytokine Profiling.

Authors:  Tanusha Singh; Braimoh Bello; Mohamed F Jeebhay
Journal:  Front Allergy       Date:  2021-11-18

7.  Antiviral, Immunomodulatory and Antiproliferative Activities of Recombinant Soluble IFNAR2 without IFN-ß Mediation.

Authors:  Isaac Hurtado-Guerrero; Bruno Hernáez; María J Pinto-Medel; Esther Calonge; José L Rodriguez-Bada; Patricia Urbaneja; Ana Alonso; Natalia Mena-Vázquez; Pablo Aliaga; Shohreh Issazadeh-Navikas; José Pavia; Laura Leyva; José Alcamí; Antonio Alcamí; Óscar Fernández; Begoña Oliver-Martos
Journal:  J Clin Med       Date:  2020-03-31       Impact factor: 4.241

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.