Literature DB >> 27766699

Multishot cartesian turbo spin-echo diffusion imaging using iterative POCSMUSE Reconstruction.

Zhe Zhang1, Bing Zhang2, Ming Li2, Xue Liang2, Xiaodong Chen1,3, Renyuan Liu2, Xin Zhang2, Hua Guo1.   

Abstract

PURPOSE: To report a diffusion imaging technique insensitive to off-resonance artifacts and motion-induced ghost artifacts using multishot Cartesian turbo spin-echo (TSE) acquisition and iterative POCS-based reconstruction of multiplexed sensitivity encoded magnetic resonance imaging (MRI) (POCSMUSE) for phase correction.
MATERIALS AND METHODS: Phase insensitive diffusion preparation was used to deal with the violation of the Carr-Purcell-Meiboom-Gill (CPMG) conditions of TSE diffusion-weighted imaging (DWI), followed by a multishot Cartesian TSE readout for data acquisition. An iterative diffusion phase correction method, iterative POCSMUSE, was developed and implemented to eliminate the ghost artifacts in multishot TSE DWI. The in vivo human brain diffusion images (from one healthy volunteer and 10 patients) using multishot Cartesian TSE were acquired at 3T and reconstructed using iterative POCSMUSE, and compared with single-shot and multishot echo-planar imaging (EPI) results. These images were evaluated by two radiologists using visual scores (considering both image quality and distortion levels) from 1 to 5.
RESULTS: The proposed iterative POCSMUSE reconstruction was able to correct the ghost artifacts in multishot DWI. The ghost-to-signal ratio of TSE DWI using iterative POCSMUSE (0.0174 ± 0.0024) was significantly (P < 0.0005) smaller than using POCSMUSE (0.0253 ± 0.0040). The image scores of multishot TSE DWI were significantly higher than single-shot (P = 0.004 and 0.006 from two reviewers) and multishot (P = 0.008 and 0.004 from two reviewers) EPI-based methods.
CONCLUSION: The proposed multishot Cartesian TSE DWI using iterative POCSMUSE reconstruction can provide high-quality diffusion images insensitive to motion-induced ghost artifacts and off-resonance related artifacts such as chemical shifts and susceptibility-induced image distortions. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:167-174.
© 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  diffusion phase correction; diffusion-weighted imaging; iterative POCSMUSE; multishot TSE DWI; off-resonance artifacts

Mesh:

Substances:

Year:  2016        PMID: 27766699     DOI: 10.1002/jmri.25522

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  2 in total

1.  Performance of U-net based pyramidal lucas-kanade registration on free-breathing multi-b-value diffusion MRI of the kidney.

Authors:  Jun Lv; Wenjian Huang; Jue Zhang; Xiaoying Wang
Journal:  Br J Radiol       Date:  2018-03-28       Impact factor: 3.039

2.  Body diffusion-weighted imaging using magnetization prepared single-shot fast spin echo and extended parallel imaging signal averaging.

Authors:  Eric K Gibbons; Shreyas S Vasanawala; John M Pauly; Adam B Kerr
Journal:  Magn Reson Med       Date:  2017-10-17       Impact factor: 4.668

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.