Literature DB >> 27766526

Implementation of a novel postoperative monitoring system using automated Modified Early Warning Scores (MEWS) incorporating end-tidal capnography.

Joseph M Blankush1, Robbie Freeman1, Joy McIlvaine1, Trung Tran1, Stephen Nassani1, I Michael Leitman2.   

Abstract

Modified Early Warning Scores (MEWS) provide real-time vital sign (VS) trending and reduce ICU admissions in post-operative patients. These early warning calculations classically incorporate oxygen saturation, heart rate, respiratory rate, systolic blood pressure, and temperature but have not previously included end-tidal CO2 (EtCO2), more recently identified as an independent predictor of critical illness. These systems may be subject to failure when physiologic data is incorrectly measured, leading to false alarms and increased workload. This study investigates whether the implementation of automated devices that utilize ongoing vital signs monitoring and MEWS calculations, inclusive of a score for end-tidal CO2 (EtCO2), can be feasibly implemented on the general care hospital floor and effectively identify derangements in a post-operative patient's condition while limiting the amount of false alarms that would serve to increase provider workload. From July to November 2014, post-operative patients meeting the inclusion criteria (BMI > 30 kg/m2, history of obstructive sleep apnea, or the use of patient-controlled analgesia (PCA) or epidural narcotics) were monitored using automated devices that record minute-by-minute VS included in classic MEWS calculations as well as EtCO2. Automated messages via pagers were sent to providers for instances when the device measured elevated MEWS, abnormal EtCO2, and oxygen desaturations below 85 %. Data, including alarm and message details from the first 133 patients, were recorded and analyzed. Overall, 3.3 alarms and pages sounded per hour of monitoring. Device-only alarms sounded 2.7 times per hour-21 % were technical alarms. The remaining device-only alarms for concerning VS sounded 2.0/h, 70 % for falsely recorded VS. Pages for abnormal EtCO2 sounded 0.4/h (82 % false recordings) while pages for low blood oxygen saturation sounded 0.1/h (55 % false alarms). 143 times (0.1 pages/h) the devices calculated a MEWS warranting a page (rise in MEWS by 2 or 5 or greater)-62 % were false scores inclusive of falsely recorded VS. An abnormal EtCO2 value resulted in or added to an elevated MEWS score in 29 % of notifications, but 50 % of these included a falsely abnormal EtCO2 value. To date, no adverse events have occurred. There were no statistically significant demographic, post-operative condition, or pre-existing comorbidity differences between patients who had a majority of true alarms from those who had mostly false-positive alarms. Although not statistically significant, the group of patients in whom automated MEWS suggested greater utility included those with a history of hypertension (p = 0.072) and renal disease (p = 0.084). EtCO2 monitoring was more likely to be useful in patients with a history of type 2 diabetes, coronary artery disease, and obstructive sleep apnea (p < 0.05). These patients were also more likely to have been on a PCA post-operatively (p < 0.05). Overall, non-invasive physiologic monitoring incorporating an automated MEWS system, modified to include end-tidal CO2 can be feasibly implemented in a hospital ward. Further study is needed to evaluate its clinical utility, including an end-tidal CO2 score, is feasibly implemented and can be useful in monitoring select post-operative patients for derangements in physiologic metrics. Like any other monitoring system, false alarms may occur at high rates. While further study is needed to determine the additive utility of EtCO2 in MEWS calculations, this study suggests utility of EtCO2 in select post-operative patients.

Entities:  

Keywords:  Automated; Capnography; End-tidal; MEWS; Monitoring; Non-invasive; Oximetry; Post-operative; Surgery

Mesh:

Substances:

Year:  2016        PMID: 27766526     DOI: 10.1007/s10877-016-9943-4

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  35 in total

1.  A prospective controlled trial of the effect of a multi-faceted intervention on early recognition and intervention in deteriorating hospital patients.

Authors:  I A Mitchell; H McKay; C Van Leuvan; R Berry; C McCutcheon; B Avard; N Slater; T Neeman; P Lamberth
Journal:  Resuscitation       Date:  2010-04-07       Impact factor: 5.262

2.  Long-term effect of introducing an early warning score on respiratory rate charting on general wards.

Authors:  Jackie McBride; Debbie Knight; Jo Piper; Gary B Smith
Journal:  Resuscitation       Date:  2005-04       Impact factor: 5.262

3.  Failure to rescue: a preliminary study of patient-level factors.

Authors:  Kathleen L Bobay; Karen L Fiorelli; Alfred J Anderson
Journal:  J Nurs Care Qual       Date:  2008 Jul-Sep       Impact factor: 1.597

Review 4.  Heart rate variability in critical illness and critical care.

Authors:  Timothy G Buchman; Phyllis K Stein; Brahm Goldstein
Journal:  Curr Opin Crit Care       Date:  2002-08       Impact factor: 3.687

5.  Alarm fatigue: a patient safety concern.

Authors:  Sue Sendelbach; Marjorie Funk
Journal:  AACN Adv Crit Care       Date:  2013 Oct-Dec

6.  The effect of implementing a modified early warning scoring (MEWS) system on the adequacy of vital sign documentation.

Authors:  Naomi E Hammond; Amy J Spooner; Adrian G Barnett; Amanda Corley; Peter Brown; John F Fraser
Journal:  Aust Crit Care       Date:  2012-05-29       Impact factor: 2.737

7.  Effect of introducing the Modified Early Warning score on clinical outcomes, cardio-pulmonary arrests and intensive care utilisation in acute medical admissions.

Authors:  C P Subbe; R G Davies; E Williams; P Rutherford; L Gemmell
Journal:  Anaesthesia       Date:  2003-08       Impact factor: 6.955

8.  APACHE-acute physiology and chronic health evaluation: a physiologically based classification system.

Authors:  W A Knaus; J E Zimmerman; D P Wagner; E A Draper; D E Lawrence
Journal:  Crit Care Med       Date:  1981-08       Impact factor: 7.598

9.  Continuous multiorgan variability analysis to track severity of organ failure in critically ill patients.

Authors:  Geoffrey C Green; Beverly Bradley; Andrea Bravi; Andrew J E Seely
Journal:  J Crit Care       Date:  2013-05-29       Impact factor: 3.425

Review 10.  A critical assessment of monitoring practices, patient deterioration, and alarm fatigue on inpatient wards: a review.

Authors:  J Paul Curry; Carla R Jungquist
Journal:  Patient Saf Surg       Date:  2014-06-27
View more
  6 in total

1.  Using the capnogram to assess pulmonary perfusion during a lobectomy: case studies.

Authors:  Jinjun Shu; Kexian Zhang; Yiding Chen; Hongwei Zhang; Jiang Zou; Yumin Tang; Jifu Dong; Yi Du
Journal:  J Clin Monit Comput       Date:  2019-01-17       Impact factor: 2.502

Review 2.  Journal of Clinical Monitoring and Computing 2017 end of year summary: respiration.

Authors:  D S Karbing; G Perchiazzi; S E Rees; M B Jaffe
Journal:  J Clin Monit Comput       Date:  2018-02-26       Impact factor: 2.502

3.  Linshom thermodynamic sensor is a reliable alternative to capnography for monitoring respiratory rate.

Authors:  David Preiss; Benjamin A Drew; James Gosnell; Bhavani S Kodali; James H Philip; Richard D Urman
Journal:  J Clin Monit Comput       Date:  2017-02-22       Impact factor: 2.502

4.  Detection of deteriorating patients after Whipple surgery by a modified early warning score (MEWS).

Authors:  Min Yu; Bowen Huang; Peizhen Liu; Aimei Wang; Wenliang Ding; Yanyun Zhai; Yaqi Huang; Yuexiu Zhong; Zhixiang Jian; Huigen Huang; Baohua Hou; Dailan Xiong
Journal:  Ann Transl Med       Date:  2019-10

5.  A Pilot Study of End-Tidal Carbon Dioxide in Prediction of Inhospital Cardiac Arrests.

Authors:  Jeffrey J Mucksavage; Kevin J He; James Chang; Maria Panlilio-Villanueva; Tianxiu Wang; Dustin Fraidenburg; Scott T Benken
Journal:  Crit Care Explor       Date:  2020-09-25

6.  Clinical decision support for intervention reduction in neonatal patients: A usability assessment.

Authors:  Patrice D Tremoulet
Journal:  Digit Health       Date:  2022-08-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.