Bioinspired helical graft with taper to enhance helical flow.

Xiao Liu1, Libing Wang1, Zhenze Wang2, Zhengxing Li1, Hongyan Kang1, Yubo Fan3, Anqiang Sun4, Xiaoyan Deng5.   

Abstract

Helical flow has been introduced to improve the hemodynamic performance of vascular devices such as arterial grafts, stents and arteriovenous shunts to overcome the flow induced thrombus formation and intimal hyperplasia. However, the quite low intensity of helical flow in the existing devices may limit their function. To obtain desirably high intensity, inspired by the helical flow and tapered configuration of the arterial system, we proposed a new conceptual design of the medical devices, which take the form of a tapered helical shape. We demonstrated its effectiveness in arterial grafts by numerically comparing the hemodynamic performance of helical grafts with different smooth tapers. The results show that the helicity density quantifying the helical flow enlarges sharply with the increase of the taper under both steady and pulsatile flow conditions. Moreover, the amplified helical flow induced by the taper would lead to highly elevated wall shear stress, remarkably reduced oscillating shear index and relative residence time at both the grafts and the anastomosis of the host vessel. The present findings therefore indicated that the new helical graft with taper would significantly enhance the helical flow in the grafts and host vessel, which may reduce the possibility of thrombus formation in the graft and intimal hyperplasia in the host vessel and hence improve the graft patency. In addition, the concept of helical shape with taper may also be applied to design arterial stents and arteriovenous shunts to obtain better hemodynamic performance. Copyright Â
© 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Graft; Helical flow; Intimal hyperplasia; Taper; Thrombosis

Mesh:

Year:  2016        PMID: 27745696     DOI: 10.1016/j.jbiomech.2016.09.028

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  2 in total

1.  Length Redundancy and Twist Improve the Biomechanical Properties of Polytetrafluoroethylene Bypass Grafts.

Authors:  Regent Lee; Miranda Stoddart; Igor Dyson; Ismail Cassimjee; Ashok Handa; Christopher P Cheng
Journal:  Ann Vasc Surg       Date:  2019-07-15       Impact factor: 1.466

2.  Numerical and Experimental Investigation of Novel Blended Bifurcated Stent Grafts with Taper to Improve Hemodynamic Performance.

Authors:  Ming Liu; Zhenze Wang; Anqiang Sun; Xiaoyan Deng
Journal:  Comput Math Methods Med       Date:  2018-09-09       Impact factor: 2.238

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.