Dong Wook Lee1, Hyeong Ho Jo1, Juveria Abdullah2, Michel Kahaleh2.
Abstract
Endoscopic treatment of biliary strictures involving plastic stent placement has been used widely. The use of self-expandable metal stents (SEMSs) has been described for anastomotic strictures following liver transplantation (LT). This review aimed to assess and compare the efficacy of plastic stents with SEMS in LT patients. Information was retrieved regarding technical success, stricture resolution, the number of endoscopic retrograde cholangiography procedures, follow-up, immediate, and late complications. Eight studies involving plastic stents had a stricture resolution rate of 84.5%, with the rates ranging from 63% to 100%. These rates are comparable with the stricture resolution rate of 75% determined from six studies that involved 236 patients who received metal stents and the rates ranged from 53% to 81%. The observed success rate for metal stents used to manage post-LT anastomotic biliary strictures was below the reported rate for multiple plastic stents. Hence, the currently available metal stents should not be offered for the management of post-LT anastomotic biliary strictures.Entities:
Keywords: Biliary stenting; Endoscopic retrograde cholangiography; Liver transplantation; Self expandable metallic stents
Year: 2016 PMID: 27744664 PMCID: PMC5066406 DOI: 10.5946/ce.2016.130
Source DB: PubMed Journal: Clin Endosc ISSN: 2234-2400
Data from Multiple Plastic Stents Insertion for Treatment of Anastomosis Stricture after Liver Transplantation
| Study | Patients | No. of stents | Stent duration, mo | No. of ERC | F/U duration, mo | Resolution of AS, | Recurrence of AS, | Complications |
|---|---|---|---|---|---|---|---|---|
| Rerknimitr et al. (2002) [ | 43 | 2.8 | 15.8 | 3.8 | 56.5 | 43/43 (100) | 0/43 (0) | Stent migration, fistula, bleeding (no. of cases not listed) |
| Alazmi et al. (2006) [ | 148 | 3 | 2.5 | 3 | 32 | 131/148 (89) | 24/131 (18) | - |
| Pasha et al. (2007) [ | 25 | 2 | 4.65 | 3.5 | 21.5 | 22/25 (88) | 2/22 (9) | 5/105 ERC (4.8%): pancreatitis, fever, stent migration, hypoxia |
| Holt et al. (2007) [ | 53 | 11 | 3 | 18 | 34/53 (63) | 1/34 (3) | 11/53 Patients (20%): pancreatitis, minor complications (not listed) | |
| Morelli et al. (2008) [ | 38 | 2.5 | 3.5 | 3.45 | 12 | 33/38 (87) | 5/33 (15) | 2/38 Patients (5%): cholangitis |
| Tabibian et al. (2010) [ | 69 | 2.5 | 15 | 4.2 | 11 | 65/69 (94) | 2/65 (3) | 4/268 ERC (1.5%): pancreatitis, bacteremia |
| Albert et al. (2013) [ | 47 | 2.5 | 28 | 4.2 | 36 | 26/47 (63) | 15/41 (37) | 32/198 ERC (16%): cholangitis, pancreatitis, bleeding, perforation |
| Poley et al. (2013) [ | 31 | 4 | - | 5 | 28 | 25/31 (80) | - | 21/31 Patients (67%): cholangitis, pancreatitis, cholestasis |
ERC, endoscopic retrograde cholangiography; F/U, follow-up; AS, anastomotic stricture.
Data from Full-Covered Metal Stent Insertion for Treatment of Anastomosis Stricture after Liver Transplantation
| Study | Patients | Stent duration, mo | F/U duration, mo | Resolution of AS, | Recurrence of AS, | Complications |
|---|---|---|---|---|---|---|
| Traina et al. (2009) [ | 16 | 2 | 10 | 13/16 (81) | 1/13 (7) | 7/16 Patients (44%): stent migration (38%), pancreatitis |
| Poley et al. (2012) [ | 23 | 5.5 | 15.5 | 14/23 (61) | - | 6/23 Patients (26%): stent migration (4%), cholangitis, cholecystitis |
| Tarantino et al. (2012) [ | 39 (group 1)[ | 2 | 22.1 | 28/39 (72) | 4/28 (14) | 13/39 Patients (33%): stent migration |
| 15 (group 2)[ | 14.4 | 8/15 (53) | 2/8 (25) | 7/15 Patients (46%): stent migration | ||
| Sauer et al. (2012) [ | 19 | 2-3 | 12 | 6/8[ | 1/6 (17) | 8/19 Patients (42%): stent migration, occlusion, stricture |
| Kahaleh et al. (2013) [ | 35 | 3.1 | - | 19/31 (61) | - | 36% Stent migration |
F/U, follow-up; AS, anastomotic stricture.
Group 1: self-expandable metal stent (SEMS) insertion after treatment failure of conventional plastic stent insertion;
Group 2: SEMS insertion at first line therapy of AS;
Only eight patients diagnosed AS after liver transplantation.
The Comparison of Resolution, Recurrence, and Complication Rate after Treatment in Anastomosis Stricture in Multiple Plastic Stent Group and Full-Covered Metal Stent Group
| Variable | Multiple plastic stent group | Full-covered metal stent group | |
|---|---|---|---|
| Stent duration, mo | 10.01±8.30 | 2.87±1.22 | 0.000 |
| Resolution | 369 (87.2) | 55 (61.8) | 0.003 |
| Recurrence | 49 (13.3) | 8 (14.5) | 0.797 |
| Complication | 75 (29.0) | 54 (36.7) | 0.065 |
Values are presented as mean±SD or number (%).