Literature DB >> 27743128

New automated indirect immunofluorescent antinuclear antibody testing compares well with established manual immunofluorescent screening and titration for antinuclear antibody on HEp-2 cells.

M Daves1, J Blecken2, T Matthias2, A Frey2, V Perkmann3, A Dall Acqua3, A Joos3, S Platzgummer3.   

Abstract

The IIF using the HEp-2 cell substrate should be still considered the "gold standard" techniques for determination of antinuclear antibody (ANA). Standardization and automation can be considered to be still in progress. Aim of this study was to evaluate the performance of the commercially automated indirect immunofluorescent antinuclear HEp-2 antibody assay. The study was designed to compare two commercially available HEp-2 ANA by indirect immunofluorescent antibody assays using a sensitivity panel (120 clinically determined patients) and a specificity panel consisting of 78 clinically confirmed negative patients. We compared the NOVA View® system [INOVA Diagnostics San Diego, USA] with the new HELIOS Processor from AESKU Systems/AESKU.Diagnostics (Wendelsheim, Germany) to assess their capability for screening, pattern recognition and titration of the samples. These automated methods were directly compared to manual reading of the same processed slides on respective microscopes and also compared with the known clinical information. The results of the two automated methods were in very good agreement with recognizing negative and positive samples. The HELIOS system detected 188 samples correctly as negative or positive versus 187 detected by the NOVA View® system. The diagnostic sensitivity of the systems was 95.8 versus 96.7 % for HELIOS and NOVA View®, respectively. The systems exhibited a diagnostic specificity of 93.5 % for the HELIOS system and 91.0 % for the NOVA View®. Both systems are suitable for fast and reliable detection of positivity/negativity due to their high sensitivity and will lead to a further increase of standardization in autoimmunity.

Entities:  

Keywords:  Antinuclear antibody; Autoimmune diseases; Automated systems; HEp-2 cell; Indirect immunofluorescent techniques

Mesh:

Substances:

Year:  2017        PMID: 27743128     DOI: 10.1007/s12026-016-8874-y

Source DB:  PubMed          Journal:  Immunol Res        ISSN: 0257-277X            Impact factor:   2.829


  15 in total

Review 1.  Computer-assisted classification of HEp-2 immunofluorescence patterns in autoimmune diagnostics.

Authors:  Ulrich Sack; Stephan Knoechner; Holger Warschkau; Ullrich Pigla; Frank Emmrich; Manja Kamprad
Journal:  Autoimmun Rev       Date:  2003-09       Impact factor: 9.754

2.  Evidence-based guidelines for the use of immunologic tests: antinuclear antibody testing.

Authors:  Daniel H Solomon; Arthur J Kavanaugh; Peter H Schur
Journal:  Arthritis Rheum       Date:  2002-08

3.  Automated interpretation of subcellular patterns from immunofluorescence microscopy.

Authors:  Yanhua Hu; Robert F Murphy
Journal:  J Immunol Methods       Date:  2004-07       Impact factor: 2.303

4.  The antinuclear antibody test: last or lasting gasp?

Authors:  Marvin J Fritzler
Journal:  Arthritis Rheum       Date:  2011-01

5.  Efficiency of different strategies to detect autoantibodies to extractable nuclear antigens.

Authors:  Delia Almeida González; Antonio Cabrera de León; María Del Cristo Rodríguez Pérez; Buenaventura Brito Díaz; Ana González Hernández; Diego García García; Carmen Vázquez Moncholi; Armando Aguirre Jaime
Journal:  J Immunol Methods       Date:  2010-06-21       Impact factor: 2.303

6.  Screening for IgG antinuclear autoantibodies by HEp-2 indirect fluorescent antibody assays and the need for standardization.

Authors:  Susan S Copple; S Rashelle Giles; Troy D Jaskowski; Anna E Gardiner; Andrew M Wilson; Harry R Hill
Journal:  Am J Clin Pathol       Date:  2012-05       Impact factor: 2.493

7.  Automation in indirect immunofluorescence testing: a new step in the evolution of the autoimmunology laboratory.

Authors:  Renato Tozzoli; Antonio Antico; Brunetta Porcelli; Danila Bassetti
Journal:  Auto Immun Highlights       Date:  2012-07-13

Review 8.  Toward a new autoantibody diagnostic orthodoxy: understanding the bad, good and indifferent.

Authors:  Marvin J Fritzler
Journal:  Auto Immun Highlights       Date:  2012-03-21

Review 9.  Efficiency of a solid-phase chemiluminescence immunoassay for detection of antinuclear and cytoplasmic autoantibodies compared with gold standard immunoprecipitation.

Authors:  Carmen Gelpí; Elena Pérez; Cristina Roldan
Journal:  Auto Immun Highlights       Date:  2014-07-18

Review 10.  Missing links in high quality diagnostics of inflammatory systemic rheumatic diseases: It is all about the patient!

Authors:  Allan S Wiik; Nicola Bizzaro
Journal:  Auto Immun Highlights       Date:  2012-04-11
View more
  2 in total

Review 1.  Recent Approaches To Optimize Laboratory Assessment of Antinuclear Antibodies.

Authors:  Anne E Tebo
Journal:  Clin Vaccine Immunol       Date:  2017-12-05

2.  Evaluation of a Fully Automated Antinuclear Antibody Indirect Immunofluorescence Assay in Routine Use.

Authors:  Hyun-Woo Choi; Yong Jun Kwon; Ju-Heon Park; Seung-Yeob Lee; Sejong Chun; Eun Jeong Won; Jun Hyung Lee; Hyun-Jung Choi; Soo Hyun Kim; Myung-Geun Shin; Jong-Hee Shin; Seung-Jung Kee
Journal:  Front Immunol       Date:  2020-12-04       Impact factor: 7.561

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.