Literature DB >> 27741494

Micro-CT based finite element models of cancellous bone predict accurately displacement once the boundary condition is well replicated: A validation study.

Yuan Chen1, Enrico Dall Ara2, Erika Sales3, Krishnagoud Manda3, Robert Wallace4, Pankaj Pankaj3, Marco Viceconti5.   

Abstract

Non-destructive 3D micro-computed tomography (microCT) based finite element (microFE) models are used to estimate bone mechanical properties at tissue level. However, their validation remains challenging. Recent improvements in the quantification of displacements in bone tissue biopsies subjected to staged compression, using refined Digital Volume Correlation (DVC) techniques, now provide a full field displacement information accurate enough to be used for microFE validation. In this study, three specimens (two humans and one bovine) were tested with two different experimental set-ups, and the resulting data processed with the same DVC algorithm. The resulting displacement vector field was compared to that predicted by microFE models solved with three different boundary conditions (BC): nominal force resultant, nominal displacement resultant, distributed displacement. The first two conditions were obtained directly from the measurements provided by the experimental jigs, whereas in the third case the displacement field measured by the DVC in the top and bottom layer of the specimen was applied. Results show excellent relationship between the numerical predictions (x) and the experiments (y) when using BC derived from the DVC measurements (UX: y=1.07x-0.002, RMSE: 0.001mm; UY: y=1.03x-0.001, RMSE: 0.001mm; UZ: y=x+0.0002, RMSE: 0.001 mm for bovine specimen), whereas only poor correlation was found using BCs according to experiment set-ups. In conclusion, microFE models were found to predict accurately the vectorial displacement field using interpolated displacement boundary condition from DVC measurement.
Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

Entities:  

Keywords:  Cancellous bone; DVC; MicroCT; Validation; microFE

Mesh:

Year:  2016        PMID: 27741494     DOI: 10.1016/j.jmbbm.2016.09.014

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  15 in total

1.  Material Mapping of QCT-Derived Scapular Models: A Comparison with Micro-CT Loaded Specimens Using Digital Volume Correlation.

Authors:  Nikolas K Knowles; Jonathan Kusins; Mohammadreza Faieghi; Melissa Ryan; Enrico Dall'Ara; Louis M Ferreira
Journal:  Ann Biomed Eng       Date:  2019-07-11       Impact factor: 3.934

Review 2.  Patient-Specific Bone Multiscale Modelling, Fracture Simulation and Risk Analysis-A Survey.

Authors:  Amadeus C S de Alcântara; Israel Assis; Daniel Prada; Konrad Mehle; Stefan Schwan; Lucia Costa-Paiva; Munir S Skaf; Luiz C Wrobel; Paulo Sollero
Journal:  Materials (Basel)       Date:  2019-12-24       Impact factor: 3.623

Review 3.  On challenges in clinical assessment of hip fracture risk using image-based biomechanical modelling: a critical review.

Authors:  Yunhua Luo
Journal:  J Bone Miner Metab       Date:  2021-01-09       Impact factor: 2.626

4.  Non-invasive prediction of the mouse tibia mechanical properties from microCT images: comparison between different finite element models.

Authors:  S Oliviero; M Roberts; R Owen; G C Reilly; I Bellantuono; E Dall'Ara
Journal:  Biomech Model Mechanobiol       Date:  2021-02-01

5.  Assessment of Intravertebral Mechanical Strains and Cancellous Bone Texture Under Load Using a Clinically Available Digital Tomosynthesis Modality.

Authors:  Daniel Oravec; Joshua Drost; Roger Zauel; Michael J Flynn; Yener N Yeni
Journal:  J Biomech Eng       Date:  2021-10-01       Impact factor: 1.899

6.  Micro Finite Element models of the vertebral body: Validation of local displacement predictions.

Authors:  Maria Cristiana Costa; Gianluca Tozzi; Luca Cristofolini; Valentina Danesi; Marco Viceconti; Enrico Dall'Ara
Journal:  PLoS One       Date:  2017-07-11       Impact factor: 3.240

7.  Effect of size and location of simulated lytic lesions on the structural properties of human vertebral bodies, a micro-finite element study.

Authors:  M C Costa; L B Bresani Campello; M Ryan; J Rochester; M Viceconti; E Dall'Ara
Journal:  Bone Rep       Date:  2020-03-09

8.  Real-time finite element analysis allows homogenization of tissue scale strains and reduces variance in a mouse defect healing model.

Authors:  Graeme R Paul; Esther Wehrle; Duncan C Tourolle; Gisela A Kuhn; Ralph Müller
Journal:  Sci Rep       Date:  2021-06-29       Impact factor: 4.379

9.  Effect of repeated in vivo microCT imaging on the properties of the mouse tibia.

Authors:  Sara Oliviero; Mario Giorgi; Peter J Laud; Enrico Dall'Ara
Journal:  PLoS One       Date:  2019-11-21       Impact factor: 3.240

10.  A new approach to comprehensively evaluate the morphological properties of the human femoral head: example of application to osteoarthritic joint.

Authors:  M Ryan; L Barnett; J Rochester; J M Wilkinson; E Dall'Ara
Journal:  Sci Rep       Date:  2020-03-26       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.