Contrast-enhanced ultrasound (CEUS) is an emerging technique to evaluate tissue perfusion. Promising results have been obtained in the evaluation of renal perfusion in health and disease, both in human and veterinary medicine. Renal scintigraphy using 99mTc-Mercaptoacetyltriglycine (MAG3) is another non-invasive technique that can be used to evaluate renal perfusion. However, no data are available on the ability of CEUS or 99mTc- MAG3 scintigraphy to detect small changes in renal perfusion in cats. Therefore, both techniques were applied in a normal feline population to evaluate detection possibilities of perfusion changes by angiotensin II (AT II). Contrast-enhanced ultrasound using a bolus injection of commercially available contrast agent and renal scintigraphy using 99mTc-MAG3 were performed in 11 healthy cats after infusion of 0,9% NaCl (control) and AT II. Angiotensin II induced changes were noticed on several CEUS parameters. Mean peak enhancement, wash-in perfusion index and wash-out rate for the entire kidney decreased significantly after AT II infusion. Moreover, a tendency towards a lower wash-in area-under-the curve was present. Renal scintigraphy could not detect perfusion changes induced by AT II. This study shows that CEUS is able to detect changes in feline renal perfusion induced by AT II infusion.Entities:
Mesh:
Substances:
Year: 2016 PMID: 27736928 PMCID: PMC5063434 DOI: 10.1371/journal.pone.0164488
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1Contrast-enhanced image of the left kidney of a cat.
Note the ROIs drawn around the entire kidney, in the renal cortex (top image), renal medulla and centered on an interlobar artery (bottom image).
Fig 2Summed dynamic dorsal images from a cat injected with 99mTc-MAG3.
Note the ROIs drawn on both kidneys with the rectangular background placed caudal to the kidneys and a rectangular ROI drawn on the aorta at the level of the kidneys.
Fig 3Changes in CEUS parameters induced by angiotensin II.
presented as means +/- standard error. * p value < 0.05. From left to right, top to bottom: peak enhancement (PE), ratio of peak enhancement with interlobar artery (PE*), wash-in area-under-the-curve (WiAUC), total area-under-the-curve (total AUC), wash-out area-under-the-curve (WoAUC), wash-in perfusion index (WiPI) and wash-out-rate (WoR). All parameters are expressed in arbitrary units.
Fig 4Changes in scintigraphic perfusion parameters induced by angiotensin II.
presented as means +/- standard error. LK: left kidney, RK: right kidney.