Literature DB >> 27721210

Real-time colour pictorial radiation monitoring during coronary angiography: effect on patient peak skin and total dose during coronary angiography.

Sharon M Wilson1, Ananth M Prasan, Amy Virdi, Marissa Lassere, Glenn Ison, David R Ramsay, James C Weaver.   

Abstract

AIMS: The aim of this study was to evaluate whether a real-time (RT) colour pictorial radiation dose monitoring system reduces patient skin and total radiation dose during coronary angiography and intervention. METHODS AND
RESULTS: Patient demographics, procedural variables and radiation parameters were recorded before and after institution of the RT skin dose recording system. Peak skin dose as well as traditionally available measures of procedural radiation dose were compared. A total of 1,077 consecutive patients underwent coronary angiography, of whom 460 also had PCI. Institution of the RT skin dose recording system resulted in a 22% reduction in peak skin dose after accounting for confounding variables. Radiation dose reduction was most pronounced in those having PCI but was also seen over a range of subgroups including those with prior coronary artery bypass surgery, high BMI, and with radial arterial access. This was associated with a significant reduction in the number of patients placed at risk of skin damage. Similar reductions in parameters reflective of total radiation dose were also demonstrated after institution of RT radiation monitoring.
CONCLUSIONS: Institution of an RT skin dose recording reduced patient peak skin and total radiation dose during coronary angiography and intervention. Consideration should be given to widespread adoption of this technology.

Entities:  

Mesh:

Year:  2016        PMID: 27721210     DOI: 10.4244/EIJV12I8A156

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  3 in total

1.  Selective anti-scatter grid removal during coronary angiography and PCI: a simple and safe technique for radiation reduction.

Authors:  James R Roy; Philip Sun; Glenn Ison; Ananth M Prasan; Tom Ford; Andrew Hopkins; David R Ramsay; James C Weaver
Journal:  Int J Cardiovasc Imaging       Date:  2017-01-24       Impact factor: 2.357

2.  Radiation doses during cardiac catheterisation procedures in India: a multicentre study: Radiation dose study.

Authors:  Vijayakumar Subban; Sophie Amelot; Suma M Victor; Anil Potdar; Vishawanath Yadav; Tejas Patel; Sanjay Shah; Thomas Alexander; Balakumaran Jeyakumaran; Juno Angel; Mullasari S Ajit
Journal:  AsiaIntervention       Date:  2020-07-20

Review 3.  Radiation protection in the cardiac catheterization laboratory.

Authors:  Sylvia Marie R Biso; Mladen I Vidovich
Journal:  J Thorac Dis       Date:  2020-04       Impact factor: 3.005

  3 in total