Comparison of three commercial dosimetric systems in detecting clinically significant VMAT delivery errors.

Sankar Arumugam1, Aitang Xing2, Tony Young3, David Thwaites3, Lois Holloway4.   

Abstract

AIM: To study the sensitivity of three commercial dosimetric systems, Delta4, Multicube and Octavius4D, in detecting Volumetric Modulated Arc Therapy (VMAT) delivery errors.
METHODS: Fourteen prostate and head and neck (H&N) VMAT plans were considered for this study. Three types of errors were introduced into the original plans: gantry angle independent and dependent MLC errors, and gantry angle dependent dose errors. The dose matrix measured by each detector system for the no-error and error introduced delivery were compared with the reference Treatment Planning System (TPS) calculated dose matrix for no-error plans using gamma (γ) analysis with 2%/2mm tolerance criteria. The ability of the detector system in identifying the minimum error in each scenario was assessed by analysing the gamma pass rates of no error delivery and error delivery using a Wilcoxon signed-rank test. The relative sensitivity of the system was assessed by determining the slope of the gamma pass line for studied error magnitude in each error scenario.
RESULTS: In the gantry angle independent and dependent MLC error scenario the Delta4, Multicube and Octavius4D systems detected a minimum 2mm error. In the gantry angle dependent dose error scenario all studied systems detected a minimum 3% and 2% error in prostate and H&N plans respectively. In the studied detector systems Multicube showed relatively less sensitivity to the errors in the majority of error scenarios.
CONCLUSION: The studied systems identified the same magnitude of minimum errors in all considered error scenarios.
Copyright © 2016 Associazione Italiana di Fisica Medica. All rights reserved.

Entities:  

Keywords:  Delivery error; Dosimetric systems; VMAT

Mesh:

Year:  2016        PMID: 27717741     DOI: 10.1016/j.ejmp.2016.09.016

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  5 in total

1.  Long-term stability of a three-dimensional dose verification system.

Authors:  Motoharu Sasaki; Hitoshi Ikushima; Wataru Sugimoto; Kenta Kitagawa
Journal:  Radiol Phys Technol       Date:  2020-01-31

2.  Evaluation of the ability of three commercially available dosimeters to detect systematic delivery errors in step-and-shoot IMRT plans.

Authors:  Alison Gray; Omemh Bawazeer; Sankar Arumugam; Philip Vial; Joseph Descallar; David Thwaites; Lois Holloway
Journal:  Rep Pract Oncol Radiother       Date:  2021-09-30

3.  Dosimetric comparison of tomotherapy and volumetric-modulated arc therapy for children with neuroblastoma.

Authors:  Xia Liu; Zhikai Liu; Tingtian Pang; Tingting Dong; Jie Qiu
Journal:  Pediatr Investig       Date:  2020-09-27

4.  Usability of detecting delivery errors during treatment of prostate VMAT with a gantry-mounted transmission detector.

Authors:  Hirofumi Honda; Masahide Tominaga; Motoharu Sasaki; Masataka Oita; Hiromitsu Kanzaki; Yasushi Hamamoto; Yoshiaki Ishii; Ryuji Yamamoto; Teruhito Mochizuki; Teruhito Kido; Yoshihiro Uto
Journal:  J Appl Clin Med Phys       Date:  2021-05-05       Impact factor: 2.102

5.  A comprehensive and clinical-oriented evaluation criteria based on DVH information and gamma passing rates analysis for IMRT plan 3D verification.

Authors:  Xin Yi; Wen-Li Lu; Jun Dang; Wei Huang; Hai-Xia Cui; Wan-Chun Wu; Ying Li; Qing-Feng Jiang
Journal:  J Appl Clin Med Phys       Date:  2020-05-20       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.