Greatly Increasing Trapped Ion Populations for Mobility Separations Using Traveling Waves in Structures for Lossless Ion Manipulations.

Liulin Deng1, Yehia M Ibrahim1, Sandilya V B Garimella1, Ian K Webb1, Ahmed M Hamid1, Randolph V Norheim1, Spencer A Prost1, Jeremy A Sandoval1, Erin S Baker1, Richard D Smith1.   

Abstract

The initial use of traveling waves (TW) for ion mobility (IM) separations using structures for lossless ion manipulations (SLIM) employed an ion funnel trap (IFT) to accumulate ions from a continuous electrospray ionization source and was limited to injected ion populations of ∼106 charges due to the onset of space charge effects in the trapping region. Additional limitations arise due to the loss of resolution for the injection of ions over longer periods, such as in extended pulses. In this work a new SLIM "flat funnel" (FF) module has been developed and demonstrated to enable the accumulation of much larger ion populations and their injection for IM separations. Ion current measurements indicate a capacity of ∼3.2 × 108 charges for the extended trapping volume, over an order of magnitude greater than that of the IFT. The orthogonal ion injection into a funnel shaped separation region can greatly reduce space charge effects during the initial IM separation stage, and the gradually reduced width of the path allows the ion packet to be increasingly compressed in the lateral dimension as the separation progresses, allowing efficient transmission through conductance limits or compatibility with subsequent ion manipulations. This work examined the TW, rf, and dc confining field SLIM parameters involved in ion accumulation, injection, transmission, and IM separation in the FF module using both direct ion current and MS measurements. Wide m/z range ion transmission is demonstrated, along with significant increases in the signal-to-noise ratios (S/N) due to the larger ion populations injected. Additionally, we observed a reduction in the chemical background, which was attributed to more efficient desolvation of solvent related clusters over the extended ion accumulation periods. The TW SLIM FF IM module is anticipated to be especially effective as a front end for long path SLIM IM separation modules.

Entities:  

Year:  2016        PMID: 27715008      PMCID: PMC5384881          DOI: 10.1021/acs.analchem.6b02678

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  31 in total

1.  Charge capacity limitations of radio frequency ion guides in their use for improved ion accumulation and trapping in mass spectrometry.

Authors:  A V Tolmachev; H R Udseth; R D Smith
Journal:  Anal Chem       Date:  2000-03-01       Impact factor: 6.986

2.  Nanoflow LC/ion mobility/CID/TOF for proteomics: analysis of a human urinary proteome.

Authors:  Myeong Hee Moon; Sunnie Myung; Manolo Plasencia; Amy E Hilderbrand; David E Clemmer
Journal:  J Proteome Res       Date:  2003 Nov-Dec       Impact factor: 4.466

3.  Development of high-sensitivity ion trap ion mobility spectrometry time-of-flight techniques: a high-throughput nano-LC-IMS-TOF separation of peptides arising from a Drosophila protein extract.

Authors:  Sunnie Myung; Young Jin Lee; Myeong Hee Moon; John Taraszka; Rena Sowell; Stormy Koeniger; Amy E Hilderbrand; Stephen J Valentine; Lucy Cherbas; Peter Cherbas; Thomas C Kaufmann; David F Miller; Yehia Mechref; Milos V Novotny; Michael A Ewing; C Ray Sporleder; David E Clemmer
Journal:  Anal Chem       Date:  2003-10-01       Impact factor: 6.986

4.  Hadamard transform ion mobility spectrometry.

Authors:  Brian H Clowers; William F Siems; Herbert H Hill; Steven M Massick
Journal:  Anal Chem       Date:  2006-01-01       Impact factor: 6.986

5.  Hadamard transform ion mobility spectrometry.

Authors:  Andrew W Szumlas; Steven J Ray; Gary M Hieftje
Journal:  Anal Chem       Date:  2006-07-01       Impact factor: 6.986

6.  Fourier transform ion mobility measurement of chain branching in mass-selected, chemically trapped oligomers from methylalumoxane-activated, metallocene-catalyzed polymerization of ethylene.

Authors:  Rolf Dietiker; Fabio di Lena; Peter Chen
Journal:  J Am Chem Soc       Date:  2007-02-16       Impact factor: 15.419

Review 7.  Ion mobility-mass spectrometry.

Authors:  Abu B Kanu; Prabha Dwivedi; Maggie Tam; Laura Matz; Herbert H Hill
Journal:  J Mass Spectrom       Date:  2008-01       Impact factor: 1.982

8.  Enhanced ion utilization efficiency using an electrodynamic ion funnel trap as an injection mechanism for ion mobility spectrometry.

Authors:  Brian H Clowers; Yehia M Ibrahim; David C Prior; William F Danielson; Mikhail E Belov; Richard D Smith
Journal:  Anal Chem       Date:  2008-01-01       Impact factor: 6.986

9.  Ion funnel trap interface for orthogonal time-of-flight mass spectrometry.

Authors:  Yehia Ibrahim; Mikhail E Belov; Aleksey V Tolmachev; David C Prior; Richard D Smith
Journal:  Anal Chem       Date:  2007-09-13       Impact factor: 6.986

10.  Development of a high-throughput IMS-IMS-MS approach for analyzing mixtures of biomolecules.

Authors:  Ruwan T Kurulugama; Stephen J Valentine; Rena A Sowell; David E Clemmer
Journal:  J Proteomics       Date:  2008-06-25       Impact factor: 4.044

View more
  7 in total

1.  Structural Elucidation of cis/trans Dicaffeoylquinic Acid Photoisomerization Using Ion Mobility Spectrometry-Mass Spectrometry.

Authors:  Xueyun Zheng; Ryan S Renslow; Mpho M Makola; Ian K Webb; Liulin Deng; Dennis G Thomas; Niranjan Govind; Yehia M Ibrahim; Mwadham M Kabanda; Ian A Dubery; Heino M Heyman; Richard D Smith; Ntakadzeni E Madala; Erin S Baker
Journal:  J Phys Chem Lett       Date:  2017-03-15       Impact factor: 6.475

2.  ISiCLE: A Quantum Chemistry Pipeline for Establishing in Silico Collision Cross Section Libraries.

Authors:  Sean M Colby; Dennis G Thomas; Jamie R Nuñez; Douglas J Baxter; Kurt R Glaesemann; Joseph M Brown; Meg A Pirrung; Niranjan Govind; Justin G Teeguarden; Thomas O Metz; Ryan S Renslow
Journal:  Anal Chem       Date:  2019-03-06       Impact factor: 6.986

3.  Assessing Collision Cross Section Calibration Strategies for Traveling Wave-Based Ion Mobility Separations in Structures for Lossless Ion Manipulations.

Authors:  Ailin Li; Christopher R Conant; Xueyun Zheng; Kent J Bloodsworth; Daniel J Orton; Sandilya V B Garimella; Isaac K Attah; Gabe Nagy; Richard D Smith; Yehia M Ibrahim
Journal:  Anal Chem       Date:  2020-11-02       Impact factor: 6.986

4.  Implementation of Ion Mobility Spectrometry-Based Separations in Structures for Lossless Ion Manipulations (SLIM).

Authors:  Adam L Hollerbach; Christopher R Conant; Gabe Nagy; Yehia M Ibrahim
Journal:  Methods Mol Biol       Date:  2022

5.  Accelerating prototyping experiments for traveling wave structures for lossless ion manipulations.

Authors:  Zackary R Kinlein; Gordon A Anderson; Brian H Clowers
Journal:  Talanta       Date:  2022-04-04       Impact factor: 6.556

6.  Ion Mobility Spectrometry with High Ion Utilization Efficiency Using Traveling Wave-Based Structures for Lossless Ion Manipulations.

Authors:  Ailin Li; Gabe Nagy; Christopher R Conant; Randolph V Norheim; Joon Yong Lee; Cameron Giberson; Adam L Hollerbach; Venkateshkumar Prabhakaran; Isaac K Attah; Christopher D Chouinard; Aneesh Prabhakaran; Richard D Smith; Yehia M Ibrahim; Sandilya V B Garimella
Journal:  Anal Chem       Date:  2020-10-26       Impact factor: 6.986

7.  Lipid and Glycolipid Isomer Analyses Using Ultra-High Resolution Ion Mobility Spectrometry Separations.

Authors:  Roza Wojcik; Ian K Webb; Liulin Deng; Sandilya V B Garimella; Spencer A Prost; Yehia M Ibrahim; Erin S Baker; Richard D Smith
Journal:  Int J Mol Sci       Date:  2017-01-18       Impact factor: 5.923

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.