Literature DB >> 27707872

In situ tissue engineering: endothelial growth patterns as a function of flow diverter design.

Miklos Marosfoi1, Erin T Langan1, Lara Strittmatter2, Kajo van der Marel1, Srinivasan Vedantham1, Jennifer Arends3, Ivan R Lylyk4, Siddharth Loganathan3, Gregory M Hendricks2, Istvan Szikora5, Ajit S Puri1, Ajay K Wakhloo1, Matthew J Gounis1.   

Abstract

BACKGROUND: Vascular remodeling in response to implantation of a tissue engineering scaffold such as a flow diverter (FD) leads to the cure of intracranial aneurysms. We hypothesize that the vascular response is dependent on FD design, and CD34+ progenitor cells play an important role in the endothelialization of the implant.
METHODS: Sixteen rabbit aneurysms were randomly treated with two different single-layer braided FDs made of cobalt-chrome alloys. The FD-48 and FD-72 devices had 48 and 72 wires, respectively. Aneurysm occlusion rate was assessed during the final digital subtraction angiogram at 10, 20, 30, and 60 days (n=2 per device per time point). Implanted vessels were analyzed with scanning electron microscopy for tissue coverage, endothelialization, and immuno-gold labeling for CD34+ cells.
RESULTS: Complete aneurysm occlusion rates were similar between the devices; however, complete or near complete occlusion was more frequently observed in aneurysms with neck ≤4.2 mm (p=0.008). Total tissue coverage at 10 days over the surface of the FD-48 and FD-72 devices was 56.4±11.6% and 76.6±3.6%, respectively. Endothelial cell growth over the surface was time-dependent for the FD-72 device (Spearman's r=0.86, p=0.013) but not for the FD-48 device (Spearman's r=-0.59, p=0.094). The endothelialization score was marginally correlated with the distance from the aneurysm neck for the FD-48 device (Spearman's r=1, p=0.083) but not for the FD-72 device (Spearman's r=0.8, p=0.33). CD34+ cells were present along the entirety of both devices at all time points.
CONCLUSIONS: This study gives preliminary evidence that temporal and spatial endothelialization is dependent on FD design. Circulating CD34+ progenitor cells contribute to endothelialization throughout the healing process. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

Entities:  

Keywords:  Aneurysm; Flow Diverter

Mesh:

Substances:

Year:  2016        PMID: 27707872     DOI: 10.1136/neurintsurg-2016-012669

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  11 in total

Review 1.  Emerging Technologies in Flow Diverters and Stents for Cerebrovascular Diseases.

Authors:  Michael Karsy; Jian Guan; Andrea A Brock; Anubhav Amin; Min S Park
Journal:  Curr Neurol Neurosci Rep       Date:  2017-10-28       Impact factor: 5.081

2.  Assessment of endothelialization of aneurysm wall over time in a rabbit model through CD31 scoring.

Authors:  Praveen Kolumam Parameswaran; Daying Dai; Yong-Hong Ding; Tina Gunderson; David F Kallmes; Ramanathan Kadirvel
Journal:  J Neurointerv Surg       Date:  2017-12-29       Impact factor: 5.836

3.  Implications of the Collar Sign in Incompletely Occluded Aneurysms after Pipeline Embolization Device Implantation: A Follow-Up Study.

Authors:  S Gomez-Paz; Y Akamatsu; J M Moore; C S Ogilvy; A J Thomas; C J Griessenauer
Journal:  AJNR Am J Neuroradiol       Date:  2020-02-13       Impact factor: 3.825

4.  How Flow Reduction Influences the Intracranial Aneurysm Occlusion: A Prospective 4D Phase-Contrast MRI Study.

Authors:  O Brina; P Bouillot; P Reymond; A S Luthman; C Santarosa; M Fahrat; K O Lovblad; P Machi; B M A Delattre; V M Pereira; M I Vargas
Journal:  AJNR Am J Neuroradiol       Date:  2019-11-14       Impact factor: 3.825

Review 5.  Mechano-regulated cell-cell signaling in the context of cardiovascular tissue engineering.

Authors:  Cansu Karakaya; Jordy G M van Asten; Tommaso Ristori; Cecilia M Sahlgren; Sandra Loerakker
Journal:  Biomech Model Mechanobiol       Date:  2021-10-06

6.  Placement of a Stent within a Flow Diverter Improves Aneurysm Occlusion Rates.

Authors:  O Ocal; A Peker; S Balci; A Arat
Journal:  AJNR Am J Neuroradiol       Date:  2019-10-03       Impact factor: 3.825

7.  Neck Location on the Outer Convexity is a Predictor of Incomplete Occlusion in Treatment with the Pipeline Embolization Device: Clinical and Angiographic Outcomes.

Authors:  T Sunohara; H Imamura; M Goto; R Fukumitsu; S Matsumoto; N Fukui; Y Oomura; T Akiyama; T Fukuda; K Go; S Kajiura; M Shigeyasu; K Asakura; R Horii; C Sakai; N Sakai
Journal:  AJNR Am J Neuroradiol       Date:  2020-11-12       Impact factor: 3.825

8.  Adaptive Remodeling in the Elastase-induced Rabbit Aneurysms.

Authors:  C Sang; D F Kallmes; R Kadirvel; M J Durka; Y-H Ding; D Dai; S C Watkins; A M Robertson
Journal:  Exp Mech       Date:  2020-10-27       Impact factor: 2.808

9.  An Improved Surgical Technique to Increase Neck Width of Elastase-Induced Aneurysm Model in Rabbits: A Prospective Study.

Authors:  Yang Zhang; Yu He; ChaoJie Tang; YuFan Wu; Yi Gu; BinXian Gu; Li Chen; WenWei Gao; ZhiGuo Zhou; YouKe Qi; FaJiang Mao; YongNing Sun; Wu Wang
Journal:  Front Neurol       Date:  2022-07-01       Impact factor: 4.086

10.  Custom tissue engineered aneurysm models with varying neck size and height for early stage in vitro testing of flow diverters.

Authors:  Camille Villadolid; Brandon Puccini; Benjamin Dennis; Tessa Gunnin; Conor Hedigan; Kristen O'Halloran Cardinal
Journal:  J Mater Sci Mater Med       Date:  2020-03-14       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.