Measurement of diagnostic x-ray spectra using a silicon photodiode.

K Aoki1, M Koyama.   

Abstract

Diagnostic x-ray spectra (66-103 kV, 1-2 mA) were measured without pinhole collimator or liquid nitrogen cooling by using a silicon p-i-n photodiode. An x-ray count rate was low (approximately 400 photons/s) at distances of 2-3 m away from an x-ray target, because the i layer of the photodiode was very small (1.5 mm2 in area and 75 microns in thickness). The junction reverse current of the photodiode was 50-70 pA at room temperature and energy resolution for 59.5-keV gamma rays was 2.0 keV (full width at half-maximum), which was limited by the electric noise of a preamplifier. Measured spectra were corrected for detector distortion. The corrected spectra were similar to those determined with a Ge detector. The i-layer thickness of the photodiode was an important parameter for the correction. In particular, when the thickness was thin, the fraction of photoelectron escape became large; this fraction was estimated analytically for various i-layer thicknesses. The angular dependence of the full-energy peak efficiency was measured; for the photons whose energies were above 17.8 keV the angular dependence was isotropic except for angles greater than 60 degrees off the photodiode axis. This method is therefore applicable to the measurement of scattered x rays.

Entities:  

Mesh:

Year:  1989        PMID: 2770626     DOI: 10.1118/1.596354

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Experimental and Monte Carlo-simulated spectra of standard mammography-quality beams.

Authors:  M G David; E J Pires; M A Bernal; J G Peixoto; C E Dealmeida
Journal:  Br J Radiol       Date:  2011-10-18       Impact factor: 3.039

2.  Possible use of CdTe detectors in kVp monitoring of diagnostic x-ray tubes.

Authors:  M Krmar; N Bucalović; M Baucal; N Jovančević
Journal:  Nucl Instrum Methods Phys Res A       Date:  2010-10-01       Impact factor: 1.455

3.  Experimental separation of diagnostic X-ray spectra into scatter and primary components.

Authors:  H Kubota; Y Ozaki; M Matsumoto; H Kanamori
Journal:  Med Biol Eng Comput       Date:  1994-07       Impact factor: 2.602

4.  Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications.

Authors:  Stefano Del Sordo; Leonardo Abbene; Ezio Caroli; Anna Maria Mancini; Andrea Zappettini; Pietro Ubertini
Journal:  Sensors (Basel)       Date:  2009-05-12       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.