| Literature DB >> 27703658 |
Chih-Chen Chang1, Yon-Cheong Wong1, Cheng-Hsien Wu1, Huan-Wu Chen1, Li-Jen Wang1, Yu-Hsien Lee1, Patricia Wanping Wu1, Wiwan Irama1, Wei Yuan Chen1, Chee-Jen Chang2.
Abstract
BACKGROUND: Low-dose computed tomography (LDCT) techniques can reduce exposure to radiation. Several previous studies have shown that radiation dose reduction in LDCT does not decrease the diagnostic performance for appendicitis among attending radiologists. But, the LDCT diagnostic performance for acute appendicitis in radiology residents with variable training levels has not been well discussed.Entities:
Keywords: Appendicitis; Computed Tomography; Education; Emergencies; Radiation Dose
Year: 2016 PMID: 27703658 PMCID: PMC5037579 DOI: 10.5812/iranjradiol.33222
Source DB: PubMed Journal: Iran J Radiol ISSN: 1735-1065 Impact factor: 0.212
Figure 1.A, Axial NE-LDCT and B, CE-SDCT images of a 29-year-old woman with acute appendicitis show appendicolith impaction (black arrow) with enlarged appendix and wall thickening (white arrow). Both reader 1 and reader 6 (1-year resident) assigned a score of 5 (definitely appendicitis) for the diagnosis of appendicitis on NE-LDCT and CE-SDCT. The BMI was 18.4 kg/m2. The dose-length product was 291.2 and 630.8 mGy cm, respectively.
Figure 2.A, Axial NE-LDCT and B, CE-SDCT images of a 51-year-old man with ruptured appendicitis show extraluminal appendicolith (black arrows) with extraluminal gas in the abscess formation (white arrows). Reader 1 and reader 6 assigned a score of 5 and 4 (probably appendicitis) for the diagnosis of appendicitis on NE-LDCT and CE-SDCT. The BMI was 19.8 kg/m2. The dose-length product was 267.7 and 627.8 mGy cm, respectively.
Figure 3.A, Coronal NE-LDCT and B, Coronal CE-SDCT images of a 64-year-old woman with acute appendicitis show dilated appendix (white arrows), wall thickening, and surrounding fat stranding (black arrows). Reader 1 and reader 6 assigned a score of 5 and 1 (definitely not appendicitis) for the diagnosis of appendicitis on NE-LDCT and a score of 5 and 5 on CE-SDCT. The BMI was 23.6 kg/m2. The dose-length product was 239.6 and 647.9 mGy cm, respectively.
Alternative Diagnoses and Their Respective Frequencies in 44 Patients who Were not Diagnosed as Acute Appendicitis
| Alternative Diagnoses | 44 Patients |
|---|---|
|
| 26 |
| Diverticulitis/diverticulosis | 18 |
| Colitis/ enteritis | 5 |
| Colon cancer | 1 |
| Small bowel perforation | 1 |
| Periappendicitis | 1 |
|
| 10 |
| Tubal-ovarian abscess | 3 |
| Pelvic inflammatory disease | 3 |
| Hemorrhagic ovarian cyst | 2 |
| Endometrioma | 2 |
|
| 4 |
|
| 2 |
|
| 1 |
|
| 1 |
Intra-Observer Comparisons of AUCs Between NE-LDCT and CE-SDCT of Each Reader [a]
| Reader | NE-LDCT | CE-SDCT | P Value | ||
|---|---|---|---|---|---|
| AUC | 95% CI | AUC | 95% CI | ||
|
| 0.970 | 0.916 to 0.994 | 0.963 | 0.905 to 0.990 | 0.738 |
|
| 0.952 | 0.891 to 0.985 | 0.944 | 0.880 to 0.980 | 0.768 |
|
| 0.972 | 0.918 to 0.994 | 0.953 | 0.892 to 0.985 | 0.433 |
|
| 0.924 | 0.854 to 0.967 | 0.973 | 0.920 to 0.995 | 0.050 |
|
| 0.888 | 0.809 to 0.942 | 0.946 | 0.882 to 0.981 | 0.053 |
|
| 0.824 | 0.736 to 0.893 | 0.882 | 0.803 to 0.938 | 0.252 |
a Abbreviations: AUC, area under the curve, CE-SDCT, contrast enhanced standard dose computed tomography; CI, confidence interval; NE-LDCT, non-enhanced low dose computed tomography; R, reader.
Figure 4.Bar charts of AUC values for the diagnosis of acute appendicitis on NE-LDCT and CE-SDCT of six readers. Statistically significant inter-observer comparisons (P < 0.05) of AUC values on both NE-LDCT (solid line) and CE-SDCT (dash line) are denoted by * (CE-SDCT, contrast enhanced standard dose computed tomography; NE-LDCT, non-enhanced low dose computed tomography; AUC, area under the curve).
Diagnostic Performance of the Six Readers on NE-LDCT and CE-SDCT Examination for Acute Appendicitis [a,b]
| Sen | Spe | Acc | |
|---|---|---|---|
| NE-LDCT | |||
|
| 91.7 | 92.5 | 92.1 |
|
| 89.6 | 84.9 | 87.1 |
|
| 85.4 | 96.2 | 91.1 |
|
| 93.8 | 81.1 | 87.1 |
|
| 85.4 | 81.1 | 83.2 |
|
| 56.3 | 94.3 | 76.2 |
|
| |||
|
| 93.8 | 94.3 | 94.1 |
|
| 93.8 | 83.0 | 88.1 |
|
| 97.9 | 86.8 | 92.1 |
|
| 97.9 | 90.6 | 94.1 |
|
| 91.7 | 92.5 | 92.1 |
|
| 60.4 | 94.3 | 78.2 |
a Abbreviations: Acc, Accuracy; CE-SDCT, contrast enhanced standard dose computed tomography; NE-LDCT, non-enhanced low dose computed tomography; R, reader; Sen, Sensitivity; Spe, Specificity.
b Data are presented as percentage.