Initial clinical results with the ThermoCool® SmartTouch® Surround Flow catheter.

Hanney Gonna1,2, Giulia Domenichini1, Zia Zuberi1,3, Mark Norman1,4, Riyaz Kaba1,5, Alexander Grimster1, Mark M Gallagher1,5.   

Abstract

AIM: The Biosense Webster ThermoCool® SmartTouch® Surround Flow (STSF) catheter is a recently developed ablation catheter incorporating Surround Flow (SF) technology to ensure efficient cooling and force sensing to quantify tissue contact. In our unit, it superseded the ThermoCool® SF catheter from the time of its introduction in May 2015. METHODS AND
RESULTS: Procedure-related data were collected prospectively for the first 100 ablation procedures performed in our department using the STSF catheter. From a database of 654 procedures performed in our unit using the SF catheter, we selected one to match each STSF procedure, matching for procedure type, operator experience, patient age, and gender. The groups were well matched for patient age, gender, and procedure type. Procedure duration was similar in both groups (mean 225.5 vs. 221.4 min, IQR 106.5 vs. 91.5, P = 0.55), but fluoroscopy duration was shorter in the STSF group (mean 25.8 vs. 30.0, IQR 19.6 vs. 18.5, P = 0.03). No complication occurred in the STSF group. Complications occurred in two cases in the SF group (one pericardial effusion requiring drainage and one need for permanent pacing). Complete procedural success was achieved in 98 cases in the STSF group and 94 cases in the SF group (P = 0.15). The composite endpoint of procedure failure or acute complication was less common in the STSF group (2 vs. 8, P = 0.05).
CONCLUSION: The STSF catheter is safe and effective in treating a range of arrhythmias. Compared with the SF catheter, it shows a trend towards improved safety-efficacy balance. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2016. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Ablation; Atrial fibrillation; Contact force sensing; Irrigated catheter; Radiofrequency; Ventricular tachycardia

Mesh:

Year:  2017        PMID: 27702870     DOI: 10.1093/europace/euw177

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  7 in total

1.  Porous tip contact force-sensing catheters for pulmonary vein isolation: performance in a clinical routine setting.

Authors:  Tobias Plenge; Jan-Hendrik van den Bruck; Jakob Lüker; Arian Sultan; Daniel Steven
Journal:  J Interv Card Electrophysiol       Date:  2019-07-19       Impact factor: 1.900

2.  The best of two worlds? Pulmonary vein isolation using a novel radiofrequency ablation catheter incorporating contact force sensing technology and 56-hole porous tip irrigation.

Authors:  Tilman Maurer; Laura Rottner; Hisaki Makimoto; Bruno Reissmann; Christian-H Heeger; Christine Lemes; Thomas Fink; Johannes Riedl; Francesco Santoro; Peter Wohlmuth; Marius Volkmer; Shibu Mathew; Andreas Metzner; Feifan Ouyang; Karl-Heinz Kuck; Christian Sohns
Journal:  Clin Res Cardiol       Date:  2018-05-08       Impact factor: 5.460

3.  Contact force sensing in ablation of ventricular arrhythmias using a 56-hole open-irrigation catheter: a propensity-matched analysis.

Authors:  Ahmed I Elbatran; Anthony Li; Mark M Gallagher; Riyaz Kaba; Mark Norman; Elijah R Behr; Manav Sohal; Abhay Bajpai; Zia Zuberi; Magdi M Saba
Journal:  J Interv Card Electrophysiol       Date:  2020-05-21       Impact factor: 1.900

4.  Impact of Variableorientation and Flow Rates on Radiofrequency Ablation Lesions Created by Externally Irrigated Catheters: An Ex-Vivo Study.

Authors:  Nishaki Mehta; Katerina Morgaenko; William Sauer; William Stevenson; David Haines
Journal:  J Atr Fibrillation       Date:  2020-10-31

5.  Procedural Efficiency, Efficacy, and Safety of High-Power, Short-Duration Radiofrequency Ablation Delivered by STSF Catheter for Paroxysmal Atrial Fibrillation.

Authors:  Cheng Cheng; Banglong Xu; Jianlong Sheng; Zheng Huang; Fei He; Feng Gao; Xiaochen Wang
Journal:  Evid Based Complement Alternat Med       Date:  2022-08-08       Impact factor: 2.650

6.  Low-fluoroscopy atrial fibrillation ablation with contact force and ultrasound technologies: a learning curve.

Authors:  Paul C Zei; Tina D Hunter; Larry M Gache; Gerri O'Riordan; Tina Baykaner; Chad R Brodt
Journal:  Pragmat Obs Res       Date:  2019-01-10

7.  Safety and efficacy of the ThermoCool SmartTouch SurroundFlow catheter for atrial fibrillation ablation: A meta-analysis.

Authors:  Chao-Feng Chen; Xiao-Fei Gao; Mei-Jun Liu; Chao-Lun Jin; Yi-Zhou Xu
Journal:  Clin Cardiol       Date:  2019-11-19       Impact factor: 2.882