| Literature DB >> 27698551 |
Adel Galal Zaky1, Ahmed Tarek Yassin2, Saber Hamed El Sayid1.
Abstract
OBJECTIVE: To assess the role and diagnostic effectiveness of optical coherence tomography (OCT) and short wave-automated perimetry (SWAP) to distinguish between normal, glaucoma suspects, and surely diagnosed glaucomatous eye.Entities:
Keywords: OCT; RNFL; SWAP; glaucoma; intraocular pressure
Year: 2016 PMID: 27698551 PMCID: PMC5034920 DOI: 10.2147/OPTH.S116073
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Demographic features among three groups
| Variable | Case group | Suspect group | Control group | ||
|---|---|---|---|---|---|
| Age | |||||
| Mean ± SD | 55.32±9.22 | 43.7±12.92 | 44.95±9.76 | 18.09 | 0.001 |
| Sex, n (%) | |||||
| Male | 20 (33.3) | 20 (33.3) | 10 (50.0) | FET=37.93 | 0.001 |
| Female | 40 (66.7) | 40 (66.7) | 10 (50.0) | FET=37.93 | 0.001 |
Abbreviation: FET, Fisher’s exact test.
RNFL thickness in (four quadrants, average, and sup/inf difference) among three groups
| Variable | Case group | Suspected group | Control group | ||
|---|---|---|---|---|---|
| Superior mean ± SD | 95.17±21.92 | 114.35±12.62 | 126.0±10.48 | 32.29 | 0.001 |
| Inferior mean ± SD | 105.4±25.05 | 117.35±18.37 | 128.0±11.53 | 10.39 | 0.001 |
| Nasal mean ± SD | 66.3±12.49 | 65.75±6.9 | 89.5±7.71 | 49.29 | 0.001 |
| Temporal mean ± SD | 63.45±15.95 | 62.05±14.12 | 70.6±8.19 | 2.72 | 0.069 |
| Sup/inf difference mean ± SD | 10.23±25.25 | 3.0±17.24 | 2.0±11.96 | 2.29 | 0.105 |
| Average thickness | 75±9.0 | 94±12 | 99±15.5 | 11.56 | 0.001 |
Abbreviations: RNFL, retinal nerve fiber layer; sup, superior; inf, inferior.
Visual field parameters among glaucoma and glaucoma suspect group
| Variable | Case group | Suspected group | Test | |
|---|---|---|---|---|
| SWAP MD mean ± SD | −8.67±7.69 | −4.47±2.95 | 0.003 | |
| SWAP PSD mean ± SD | 3.88±1.62 | 2.84±0.59 | 0.001 | |
| SAP MD mean ± SD | −7.95±9.93 | −3.06±2.94 | 0.005 | |
| SAP PSD mean ± SD | 3.34±2.4 | 2.16±1.16 | 0.001 |
Abbreviations: SWAP, short wave–automated perimetry; MD, mean deviation; PSD, pattern standard deviation; SAP, standard automated perimetry.
Correlation between SWAP PSD, SWAP MD, and RNFL thickness among glaucoma group
| Case group | SWAP MD
| SWAP PSD
| ||
|---|---|---|---|---|
| RNFL thickness | 0.387 | 0.001 | 0.111 | 0.009 |
| Superior Q OCT | 0.19 | 0.001 | 0.047 | 0.094 |
| Inferior Q OCT | 0.563 | 0.001 | 0.185 | 0.001 |
| Nasal Q OCT | 0.005 | 0.589 | 0.011 | 0.427 |
| Temporal Q OCT | 0.062 | 0.055 | 0.003 | 0.884 |
Abbreviations: SWAP, short wave–automated perimetry; MD, mean deviation; PSD, pattern standard deviation; OCT, optical coherence tomography; RNFL, retinal nerve fiber layer.
Correlation between SWAP PSD, SWAP MD and other variables among suspected group
| Suspected group | SWAP MD
| SWAP PSD
| ||
|---|---|---|---|---|
| RNFL thickness | 0.171 | 0.001 | 0.145 | 0.007 |
| Superior Q OCT | 0.173 | 0.001 | 0.134 | 0.004 |
| Inferior Q OCT | 0.252 | 0.001 | 0.416 | 0.001 |
| Nasal Q OCT | 0.113 | 0.003 | 0.035 | 0.148 |
| Temporal Q OCT | 0.01 | 0.937 | 0.014 | 0.356 |
Abbreviations: SWAP, short wave–automated perimetry; MD, mean deviation; PSD, pattern standard deviation; OCT, optical coherence tomography; RNFL, retinal nerve fiber layer.