PURPOSE: To compare the optical performance of 3 trifocal intraocular lenses (IOLs): the Acrysof IQ Panoptix (+2.17 diopter [D]/+3.25 D IOL), AT LISA Tri 839MP (+1.66 D/+3.33 D IOL), and Finevision Micro F (+1.75 D/+3.50 D IOL). SETTING: Alcon Research Ltd., Fort Worth, Texas, USA. DESIGN: Experimental study. METHODS: The 3 trifocal IOLs were compared using optical performance tests. To measure image quality, through-focus modulation transfer function (MTF) curves were generated for a model eye. To assess resolution, through-focus Badal images of an Early Treatment Diabetic Retinopathy Study chart simulating viewing distances of infinity to 40 cm were recorded. To measure photic phenomena, simulated headlight images with a 50 μm pinhole target and a 5.0 mm pupil were obtained. RESULTS: The MTF measurements showed similar near and distance peaks for the IOLs, but the optimum intermediate peak for the +2.17 D/+3.25 D IOL was 60 cm versus 80 cm for the other 2 trifocal IOLs. Similarly, in bench Badal image testing, the optimum intermediate image was at 60 cm for the +2.17 D/+3.25 D IOL and 80 cm for the other 2 IOLs. Overall, halos surrounding simulated headlight images were equivalent for the 3 IOLs. CONCLUSIONS: In bench studies, the new +2.17 D/+3.25 D trifocal IOL showed equivalent or better performance in image quality, resolution, and photic phenomena compared with the +1.66 D/+3.33 D and +1.75 D/+3.50 D trifocal IOLs. The new IOL is expected to provide better intermediate vision at 60 cm, which is preferred for real-life tasks such as computer work, over the 80 cm intermediate distance offered by the other 2 trifocal IOLs. FINANCIAL DISCLOSURE: All authors are employees of Alcon Research, Ltd.
PURPOSE: To compare the optical performance of 3 trifocal intraocular lenses (IOLs): the Acrysof IQ Panoptix (+2.17 diopter [D]/+3.25 D IOL), AT LISA Tri 839MP (+1.66 D/+3.33 D IOL), and Finevision Micro F (+1.75 D/+3.50 D IOL). SETTING: Alcon Research Ltd., Fort Worth, Texas, USA. DESIGN: Experimental study. METHODS: The 3 trifocal IOLs were compared using optical performance tests. To measure image quality, through-focus modulation transfer function (MTF) curves were generated for a model eye. To assess resolution, through-focus Badal images of an Early Treatment Diabetic Retinopathy Study chart simulating viewing distances of infinity to 40 cm were recorded. To measure photic phenomena, simulated headlight images with a 50 μm pinhole target and a 5.0 mm pupil were obtained. RESULTS: The MTF measurements showed similar near and distance peaks for the IOLs, but the optimum intermediate peak for the +2.17 D/+3.25 D IOL was 60 cm versus 80 cm for the other 2 trifocal IOLs. Similarly, in bench Badal image testing, the optimum intermediate image was at 60 cm for the +2.17 D/+3.25 D IOL and 80 cm for the other 2 IOLs. Overall, halos surrounding simulated headlight images were equivalent for the 3 IOLs. CONCLUSIONS: In bench studies, the new +2.17 D/+3.25 D trifocal IOL showed equivalent or better performance in image quality, resolution, and photic phenomena compared with the +1.66 D/+3.33 D and +1.75 D/+3.50 D trifocal IOLs. The new IOL is expected to provide better intermediate vision at 60 cm, which is preferred for real-life tasks such as computer work, over the 80 cm intermediate distance offered by the other 2 trifocal IOLs. FINANCIAL DISCLOSURE: All authors are employees of Alcon Research, Ltd.
Authors: Krzysztof Petelczyc; Andrzej Kolodziejczyk; Narcyz Błocki; Anna Byszewska; Zbigniew Jaroszewicz; Karol Kakarenko; Katarzyna Kołacz; Michał Miler; Alejandro Mira-Agudelo; Walter Torres-Sepúlveda; Marek Rękas Journal: Biomed Opt Express Date: 2019-12-04 Impact factor: 3.732
Authors: César Vilar; Wilson Takashi Hida; André Lins de Medeiros; Klayny Rafaella Pereira Magalhães; Patrick Frensel de Moraes Tzelikis; Mario Augusto Pereira Dias Chaves; Antônio Francisco Pimenta Motta; Pedro Carlos Carricondo; Milton Ruiz Alves; Walton Nosé Journal: Clin Ophthalmol Date: 2017-08-01
Authors: Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Noemi Burguera; David P Piñero Journal: J Clin Med Date: 2021-05-07 Impact factor: 4.241
Authors: André Lins de Medeiros; André Gustavo de Araújo Rolim; Antonio Francisco Pimenta Motta; Bruna Vieira Ventura; César Vilar; Mário Augusto Pereira Dias Chaves; Pedro Carlos Carricondo; Wilson Takashi Hida Journal: Clin Ophthalmol Date: 2017-10-26