Literature DB >> 27690662

Titanium-nitride-oxide-coated coronary stents: insights from the available evidence.

Pasi P Karjalainen1, Wail Nammas1.   

Abstract

Coating of stent surface with a biocompatible material is suggested to improve stent safety profile. A proprietary process was developed to coat titanium-nitride-oxide on the stent surface, based on plasma technology that uses the nano-synthesis of gas and metal. Preclinical in vitro and in vivo investigation confirmed blood compatibility of titanium (nitride-) oxide films. Titanium-nitride-oxide-coated stents demonstrated a better angiographic outcome, compared with bare-metal stents at mid-term follow-up; however, they failed to achieve non-inferiority for angiographic outcome versus second-generation drug-eluting stents. Observational studies showed adequate clinical outcome at mid-term follow-up. Non-randomized studies showed an outcome of titanium-nitride-oxide-coated stents comparable to - or better than - first-generation drug-eluting stents at long-term follow-up. Two randomized controlled trials demonstrated comparable efficacy outcome, and a better safety outcome of titanium-nitride-oxide-coated stents versus drug-eluting stents at long-term follow-up. Evaluation by optical coherence tomography at mid-term follow-up revealed better neointimal strut coverage associated with titanium-nitride-oxide-coated stents versus drug-eluting stents; yet, neointimal hyperplasia thickness was greater. Key messages Stents coated with titanium-nitride-oxide demonstrated biocompatibility in preclinical studies: they inhibit platelet and fibrin deposition, and reduce neointimal growth. In observational and non-randomized studies, titanium-nitride-oxide-coated stents were associated with adequate safety and efficacy outcome. In randomized trials of patients with acute coronary syndrome, titanium-nitride-oxide-coated stents were associated with a better safety outcome, compared with drug-eluting stents; efficacy outcome was comparable.

Entities:  

Keywords:  Outcome; percutaneous coronary intervention; titanium-nitride-oxide-coated stents

Mesh:

Substances:

Year:  2016        PMID: 27690662     DOI: 10.1080/07853890.2016.1244353

Source DB:  PubMed          Journal:  Ann Med        ISSN: 0785-3890            Impact factor:   4.709


  3 in total

Review 1.  The Newest Generation of Drug-eluting Stents and Beyond.

Authors:  Dae-Hyun Lee; Jose M de la Torre Hernandez
Journal:  Eur Cardiol       Date:  2018-08

2.  Exosome-eluting stents for vascular healing after ischaemic injury.

Authors:  Shiqi Hu; Zhenhua Li; Deliang Shen; Dashuai Zhu; Ke Huang; Teng Su; Phuong-Uyen Dinh; Jhon Cores; Ke Cheng
Journal:  Nat Biomed Eng       Date:  2021-04-05       Impact factor: 25.671

Review 3.  Health Care Monitoring and Treatment for Coronary Artery Diseases: Challenges and Issues.

Authors:  Mokhalad Alghrairi; Nasri Sulaiman; Saad Mutashar
Journal:  Sensors (Basel)       Date:  2020-08-01       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.