Literature DB >> 27688425

Titanium Ions Release from an Innovative Titanium-Magnesium Composite: an in Vitro Study.

Zlatko Stanec1, Jasna Halambek2, Krešimir Maldini3, Martin Balog4, Peter Križik4, Zdravko Schauperl5, Amir Ćatić6.   

Abstract

BACKGROUND: The innovative titanium-magnesium composite (Ti-Mg) was produced by powder metallurgy (P/M) method and is characterized in terms of corrosion behavior.
MATERIAL AND METHODS: Two groups of experimental material, 1 mass% (Ti-1Mg) and 2 mass% (Ti-2Mg) of magnesium in titanium matrix, were tested and compared to commercially pure titanium (CP Ti). Immersion test and chemical analysis of four solutions: artificial saliva; artificial saliva pH 4; artificial saliva with fluoride and Hank balanced salt solution were performed after 42 days of immersion, using inductively coupled plasma mass spectrometry (ICP-MS) to detect the amount of released titanium ions (Ti). SEM and EDS analysis were used for surface characterization.
RESULTS: The difference between the results from different test solutions was assessed by ANOVA and Newman-Keuls test at p<0.05. The influence of predictor variables was found by multiple regression analysis. The results of the present study revealed a low corrosion rate of titanium from the experimental Ti-Mg group. Up to 46 and 23 times lower dissolution of Ti from Ti-1Mg and Ti-2Mg, respectively was observed compared to the control group. Among the tested solutions, artificial saliva with fluorides exhibited the highest corrosion effect on all specimens tested. SEM micrographs showed preserved dual phase surface structure and EDS analysis suggested a favorable surface bioactivity.
CONCLUSION: In conclusion, Ti-Mg produced by P/M as a material with better corrosion properties when compared to CP Ti is suggested.

Entities:  

Keywords:  Corrosion; Immersion; Ion Exchange; Magnesium; Saliva, Artificial; Titanium

Year:  2016        PMID: 27688425      PMCID: PMC5017277          DOI: 10.15644/asc50/1/6

Source DB:  PubMed          Journal:  Acta Stomatol Croat        ISSN: 0001-7019


  30 in total

1.  Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study.

Authors:  Valentim A R Barão; Mathew T Mathew; Wirley Gonçalves Assunção; Judy Chia-Chun Yuan; Markus A Wimmer; Cortino Sukotjo
Journal:  Clin Oral Implants Res       Date:  2011-08-01       Impact factor: 5.977

2.  Local release of magnesium from mesoporous TiO2 coatings stimulates the peri-implant expression of osteogenic markers and improves osteoconductivity in vivo.

Authors:  Silvia Galli; Yoshihito Naito; Johan Karlsson; Wenxiao He; Ikuya Miyamoto; Ying Xue; Martin Andersson; Kamal Mustafa; Ann Wennerberg; Ryo Jimbo
Journal:  Acta Biomater       Date:  2014-08-18       Impact factor: 8.947

Review 3.  Titanium hypersensitivity. A hidden threat for dental implant patients?

Authors:  Hakan Bilhan; Canan Bural; Onur Geckili
Journal:  N Y State Dent J       Date:  2013 Jun-Jul

4.  Influence of a fluoridated medium with different pHs on commercially pure titanium-based implants.

Authors:  Rafael Sartori; Cassia Bellotto Correa; Elcio Marcantonio; Luis Geraldo Vaz
Journal:  J Prosthodont       Date:  2008-11-18       Impact factor: 2.752

5.  The effect of fluoride ions on the corrosion behaviour of Ti metal, and Ti6-Al-7Nb and Ti-6Al-4V alloys in artificial saliva.

Authors:  Ingrid Milošev; Barbara Kapun; Vid Simon Selih
Journal:  Acta Chim Slov       Date:  2013       Impact factor: 1.735

6.  Attachment of Porphyromonas gingivalis to corroded commercially pure titanium and titanium-aluminum-vanadium alloy.

Authors:  Valentim A R Barão; Cheon Joo Yoon; Mathew T Mathew; Judy Chia-Chun Yuan; Christine D Wu; Cortino Sukotjo
Journal:  J Periodontol       Date:  2014-01-20       Impact factor: 6.993

7.  How do titanium and Ti6Al4V corrode in fluoridated medium as found in the oral cavity? An in vitro study.

Authors:  Júlio C M Souza; Sandra L Barbosa; Edith A Ariza; Mariana Henriques; Wim Teughels; Pierre Ponthiaux; Jean-Pierre Celis; Luis A Rocha
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2014-11-20       Impact factor: 7.328

8.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man.

Authors:  T Albrektsson; P I Brånemark; H A Hansson; J Lindström
Journal:  Acta Orthop Scand       Date:  1981

9.  Mechanisms of magnesium-stimulated adhesion of osteoblastic cells to commonly used orthopaedic implants.

Authors:  H Zreiqat; C R Howlett; A Zannettino; P Evans; G Schulze-Tanzil; C Knabe; M Shakibaei
Journal:  J Biomed Mater Res       Date:  2002-11

10.  Implant failure due to titanium hypersensitivity/allergy?--Report of a case.

Authors:  L A du Preez; K W Bütow; T J P Swart
Journal:  SADJ       Date:  2007-02
View more
  1 in total

1.  Biodegradability and Cytocompatibility of 3D-Printed Mg-Ti Interpenetrating Phase Composites.

Authors:  Xixiang Yang; Wanyi Huang; Desong Zhan; Dechun Ren; Haibin Ji; Zengqian Liu; Qiang Wang; Ning Zhang; Zhefeng Zhang
Journal:  Front Bioeng Biotechnol       Date:  2022-06-28
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.