Literature DB >> 22092540

Stability of cp-Ti and Ti-6Al-4V alloy for dental implants as a function of saliva pH - an electrochemical study.

Valentim A R Barão1, Mathew T Mathew, Wirley Gonçalves Assunção, Judy Chia-Chun Yuan, Markus A Wimmer, Cortino Sukotjo.   

Abstract

OBJECTIVES: To investigate the role of different levels of pH of artificial saliva under simulated oral environment on the corrosion behavior of commercially pure titanium (cp-Ti) and Ti-6Al-4V alloy. Special attention is given to understand the changes in corrosion kinetics and surface characterization of Ti by using electrochemical impedance spectroscopy (EIS).
MATERIALS AND METHODS: Fifty-four Ti disks (15-mm diameter, 2-mm thickness) were divided into six groups (n = 9) as a function of saliva pH (3, 6.5, and 9) and Ti type. Samples were mechanically polished using standard metallographic procedures. Standard electrochemical tests, such as open circuit potential, EIS, and potentiodynamic tests were conducted in a controlled environment. Data were evaluated by two-way ANOVA, Tukey multiple comparison test, and independent t-test (α = 0.05). Ti surfaces were examined using white-light-interferometry microscopy and scanning electron microscopy (SEM).
RESULTS: Saliva pH level significantly affected the corrosion behavior of both Ti types. At low pH, acceleration of ions exchange between Ti and saliva, and reduction of resistance of Ti surface against corrosion were observed (P < 0.05). Corrosion rate was also significantly increased in acidic medium (P < 0.05). Similar corrosion behavior was observed for both Ti types. The white-light-interferometry images of Ti surfaces show higher surface changes at low pH level. SEM images do not show detectable changes. No pitting corrosion was observed for any group.
CONCLUSIONS: The pH level of artificial saliva influences the corrosion behavior of cp-Ti and Ti-6Al-4V alloy in that lower pH accelerates the corrosion rate and kinetics. The corrosion products may mitigate the survival rate of dental implants.
© 2011 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22092540     DOI: 10.1111/j.1600-0501.2011.02265.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  13 in total

1.  The effect of hyaluronic acid on the corrosion of an orthopedic CoCrMo-alloy in simulated inflammatory conditions.

Authors:  S Radice; J Yao; J Babauta; M P Laurent; M A Wimmer
Journal:  Materialia (Oxf)       Date:  2019-05-10

2.  Fretting-corrosion in Hip Implant Modular Junctions: New Experimental Set-up and Initial Outcome.

Authors:  D Royhman; M Patel; M J Runa; J J Jacobs; N J Hallab; M A Wimmer; M T Mathew
Journal:  Tribol Int       Date:  2015-11-01       Impact factor: 4.872

3.  Titanium Ions Release from an Innovative Titanium-Magnesium Composite: an in Vitro Study.

Authors:  Zlatko Stanec; Jasna Halambek; Krešimir Maldini; Martin Balog; Peter Križik; Zdravko Schauperl; Amir Ćatić
Journal:  Acta Stomatol Croat       Date:  2016-03

4.  Electrochemical behavior of bioactive coatings on cp-Ti surface for dental application.

Authors:  Isabella da Silva Vieira Marques; Valentim Adelino Ricardo Barão; Nilson Cristino da Cruz; Judy Chia-Chun Yuan; Marcelo Ferraz Mesquita; Antonio Pedro Ricomini-Filho; Cortino Sukotjo; Mathew T Mathew
Journal:  Corros Sci       Date:  2015-11-01       Impact factor: 7.205

5.  Effects of dextrose and lipopolysaccharide on the corrosion behavior of a Ti-6Al-4V alloy with a smooth surface or treated with double-acid-etching.

Authors:  Leonardo P Faverani; Wirley G Assunção; Paulo Sérgio P de Carvalho; Judy Chia-Chun Yuan; Cortino Sukotjo; Mathew T Mathew; Valentim A Barao
Journal:  PLoS One       Date:  2014-03-26       Impact factor: 3.240

6.  Fabrication of anti-aging TiO2 nanotubes on biomedical Ti alloys.

Authors:  Azhang Hamlekhan; Arman Butt; Sweetu Patel; Dmitry Royhman; Christos Takoudis; Cortino Sukotjo; Judy Yuan; Gregory Jursich; Mathew T Mathew; William Hendrickson; Amarjit Virdi; Tolou Shokuhfar
Journal:  PLoS One       Date:  2014-05-02       Impact factor: 3.240

7.  Fretting Corrosion Behavior of Experimental Ti-20Cr Compared to Titanium.

Authors:  Tomofumi Sawada; Christine Schille; Atif Almadani; Jürgen Geis-Gerstorfer
Journal:  Materials (Basel)       Date:  2017-02-17       Impact factor: 3.623

8.  Corrosion Behavior of a Nickel-Base Dental Casting Alloy in Artificial Saliva Studied by Weight Loss and Polarization Techniques.

Authors:  Elnaz Moslehifard; Mahsa Moslehifard; Sanaz Ghasemzadeh; Farzad Nasirpouri
Journal:  Front Dent       Date:  2019-01-20

9.  Titanium particles in tissues from peri-implant mucositis: An exfoliative cytology-based pilot study.

Authors:  Shree Lakshmi Deepika Penmetsa; Rucha Shah; Raison Thomas; Amanna Baron Tarun Kumar; Pamidimarri Sai Divya Gayatri; Dhoom Singh Mehta
Journal:  J Indian Soc Periodontol       Date:  2017 May-Jun

10.  Determinants of corrosion resistance of Ti-6Al-4V alloy dental implants in an In Vitro model of peri-implant inflammation.

Authors:  Larissa O Berbel; Everson do P Banczek; Ioannis K Karoussis; Georgios A Kotsakis; Isolda Costa
Journal:  PLoS One       Date:  2019-01-31       Impact factor: 3.240

View more