Literature DB >> 8598805

Imaging myocardial fiber architecture in vivo with magnetic resonance.

T G Reese1, R M Weisskoff, R N Smith, B R Rosen, R E Dinsmore, V J Wedeen.   

Abstract

Methods are presented to image the fiber architecture of the human myocardium in vitro and in vivo. NMR images are obtained of the diffusion anisotropy tensor, indicative of local myofiber orientation. Studies of cardiac necropsy specimens demonstrate classic features of ventricular myoarchitecture including the continuous endocardial to epicardial variation of fiber helix angles (angles to the ventricular circumferential direction) of approximately +1.3 to -1.3 radians. Cross-fiber anisotropy is also observed. In the beating heart, NMR diffusion data must be corrected for the effects of myocardial deformation during the cardiac cycle. This correction can be performed using an independent MRI method to map the strain-rate tensor field of the myocardium through time. Combining fiber orientation with local myocardial strain rate, local rates of myocardial fiber shortening may be computed.

Entities:  

Mesh:

Year:  1995        PMID: 8598805     DOI: 10.1002/mrm.1910340603

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  81 in total

1.  Demonstration of primary and secondary muscle fiber architecture of the bovine tongue by diffusion tensor magnetic resonance imaging.

Authors:  V J Wedeen; T G Reese; V J Napadow; R J Gilbert
Journal:  Biophys J       Date:  2001-02       Impact factor: 4.033

2.  Reconstruction of cardiac ventricular geometry and fiber orientation using magnetic resonance imaging.

Authors:  D F Scollan; A Holmes; J Zhang; R L Winslow
Journal:  Ann Biomed Eng       Date:  2000-08       Impact factor: 3.934

3.  Diffusion tensor imaging in biomechanical studies of skeletal muscle function.

Authors:  C C Van Donkelaar; L J Kretzers; P H Bovendeerd; L M Lataster; K Nicolay; J D Janssen; M R Drost
Journal:  J Anat       Date:  1999-01       Impact factor: 2.610

Review 4.  Electrophysiological modeling of cardiac ventricular function: from cell to organ.

Authors:  R L Winslow; D F Scollan; A Holmes; C K Yung; J Zhang; M S Jafri
Journal:  Annu Rev Biomed Eng       Date:  2000       Impact factor: 9.590

5.  Conductivity tensor mapping of the human brain using diffusion tensor MRI.

Authors:  D S Tuch; V J Wedeen; A M Dale; J S George; J W Belliveau
Journal:  Proc Natl Acad Sci U S A       Date:  2001-09-25       Impact factor: 11.205

Review 6.  The use of Gd-DTPA as a marker of myocardial viability in reperfused acute myocardial infarction.

Authors:  R S Pereira; F S Prato; G Wisenberg; J Sykes; K J Yvorchuk
Journal:  Int J Cardiovasc Imaging       Date:  2001-10       Impact factor: 2.357

Review 7.  Diffusion tensor imaging and its application to neuropsychiatric disorders.

Authors:  Marek Kubicki; Carl-Fredrik Westin; Stephan E Maier; Hatsuho Mamata; Melissa Frumin; Hal Ersner-Hershfield; Ron Kikinis; Ferenc A Jolesz; Robert McCarley; Martha E Shenton
Journal:  Harv Rev Psychiatry       Date:  2002 Nov-Dec       Impact factor: 3.732

Review 8.  Cardiovascular nuclear magnetic resonance: basic and clinical applications.

Authors:  John R Forder; Gerald M Pohost
Journal:  J Clin Invest       Date:  2003-06       Impact factor: 14.808

9.  Image-based estimation of ventricular fiber orientations for personalized modeling of cardiac electrophysiology.

Authors:  Fijoy Vadakkumpadan; Hermenegild Arevalo; Can Ceritoglu; Michael Miller; Natalia Trayanova
Journal:  IEEE Trans Med Imaging       Date:  2012-01-18       Impact factor: 10.048

10.  How hydrogel inclusions modulate the local mechanical response in early and fully formed post-infarcted myocardium.

Authors:  David S Li; Reza Avazmohammadi; Christopher B Rodell; Edward W Hsu; Jason A Burdick; Joseph H Gorman; Robert C Gorman; Michael S Sacks
Journal:  Acta Biomater       Date:  2020-07-30       Impact factor: 8.947

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.