Literature DB >> 27677214

Marginal and internal fit of CAD-CAM-fabricated composite resin and ceramic crowns scanned by 2 intraoral cameras.

Alessandra C de Paula Silveira1, Sacha B Chaves2, Leandro A Hilgert3, Ana Paula D Ribeiro4.   

Abstract

STATEMENT OF PROBLEM: The precision of fit of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) complete crowns is affected by digital impression and restorative material.
PURPOSE: The purpose of this in vitro study was to evaluate by microcomputed tomography (μCT) the marginal and internal adaptation of composite resin and ceramic complete crowns fabricated with 2 different intraoral cameras and 2 restorative materials.
MATERIAL AND METHODS: Ten extracted human third molars received crown preparations. For each prepared molar, 2 digital impressions were made with different intraoral cameras of the CEREC system, Bluecam and Omnicam. Four groups were formed: LB (Lava Ultimate+Bluecam), EB (Emax+Bluecam), LO (Lava Ultimate+Omnicam), and EO (Emax+Omnicam). Before measuring the precision of fit, all crowns were stabilized with a silicone material. Each unit (crown + prepared tooth) was imaged with μCT, and marginal and internal discrepancies were analyzed. For the 2D analysis, 120 measurements were made of each crown for marginal adaptation, 20 for marginal discrepancy (MD), and 20 for absolute marginal discrepancy (AMD); and for internal adaptation, 40 for axial space (AS) and 40 for occlusal space (OS). After reconstructing the 3D images, the average internal space (AIS) was calculated by dividing the total volume of the internal space by the contact surface. Data were analyzed with 2-way ANOVA and quantile regression.
RESULTS: Regarding marginal adaptation, no significant differences were observed among groups. For internal adaptation measured in the 2D evaluation, a significant difference was observed between LO and EO for the AS variable (Mann-Whitney test; P<.008). In assessment of AIS by the 3D reconstruction, LB presented significantly lower values than the other groups (Tukey post hoc test; P<.05). Bluecam presented lower values of AIS than Omnicam, and composite resin crowns showed less discrepancy than did ceramic crowns.
CONCLUSIONS: The marginal adaptations assessed in all groups showed values within the clinically accepted range. Moreover, the composite resin blocks associated with the Bluecam intraoral camera demonstrated the best results for AIS compared with those of the other groups.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27677214     DOI: 10.1016/j.prosdent.2016.07.017

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  9 in total

1.  [Influence of preparation height and cement space on the fit and retention of computer aided design/computer aided manufacturing zirconia crown].

Authors:  Shuang Xi; Zi-Xiao Wu; Cui-Cui Gao; Yu-Chen Meng; Dan-Dan Pei; Yi Lu
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-06-01

2.  A comparison of the marginal adaptation of composite overlays fabricated with silicone and an intraoral scanner.

Authors:  Carla García-Cuesta; Vicente Faus-Llácer; Álvaro Zubizarreta-Macho; René Botello-Torres; Vicente Faus-Matoses
Journal:  J Clin Exp Dent       Date:  2021-05-01

3.  Comparison of Marginal Fit and Internal Adaptation of Copings Fabricated with Polyetheretherketone and Zirconia - An In vitro Study.

Authors:  V Amalorpavam; T Sreelal; Giri Chandramohan; G N Jithin
Journal:  J Pharm Bioallied Sci       Date:  2021-11-10

4.  Comparative Evaluation of Adaptation of Esthetic Prefabricated Fiberglass and CAD/CAM Crowns for Primary Teeth: Microcomputed Tomography Analysis.

Authors:  Ece Irem Oguz; Tuğba Bezgin; Ayse Isıl Orhan; Kaan Orhan
Journal:  Biomed Res Int       Date:  2021-09-26       Impact factor: 3.411

Review 5.  Composite Resin Preheating Techniques for Cementation of Indirect Restorations.

Authors:  Déborah Lousan do Nascimento Poubel; Ana Elisa Ghanem Zanon; Júlio César Franco Almeida; Liliana Vicente Melo de Lucas Rezende; Fernanda Cristina Pimentel Garcia
Journal:  Int J Biomater       Date:  2022-03-23

6.  In vitro comparative analysis of scanning accuracy of intraoral and laboratory scanners in measuring the distance between multiple implants.

Authors:  Reiji Natsubori; Shota Fukazawa; Toyokazu Chiba; Norimasa Tanabe; Hidemichi Kihara; Hisatomo Kondo
Journal:  Int J Implant Dent       Date:  2022-04-13

7.  In Vitro Comparison of Marginal and Internal Fit of Zirconia Copings Fabricated by One CAD/CAM System with Two Different Scanners.

Authors:  Zahra Khamverdi; Elmira Najafrad; Maryam Farhadian
Journal:  Front Dent       Date:  2021-01-20

8.  In vitro accuracies of 3D printed models manufactured by two different printing technologies.

Authors:  Faruk Emir; Gulsum Ceylan; Simel Ayyildiz
Journal:  Eur Oral Res       Date:  2021-05-04

9.  Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study.

Authors:  Afra Hassan Elrashid; Amjad Hamod AlKahtani; Shatha Jarallah Alqahtani; Nouf Bati Alajmi; Fatimah Hussain Alsultan
Journal:  J Int Soc Prev Community Dent       Date:  2019-02-13
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.