Zong-Ming Song1, Xu-Ting Hu1, Lei Wang1, Zhi-Xiang Hu1, Pei-Quan Zhao2, Ding Chen1. 1. Eye Hospital, Wenzhou Medical University, Wenzhou 325027, Zhejiang Province, China. 2. Xin Hua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai 200092, China.
Abstract
AIM: To report a simple approach to actively remove high viscosity silicone oil through a 23-gauge cannula via pars plana. METHODS: Forty-eight eyes of 48 patients underwent silicone oil (5700 centistokes) removal (SOR) were enrolled. A section of blood transfusion set was prepared to connect a standard 23-gauge cannula and vitrectomy machine. Silicone oil was removed with suction of 500-mm Hg vacuum through the cannula. Main outcome measures were SOR duration, number of sutured sites, intraocular pressure (IOP), best-corrected visual acuity (BCVA), and complications. RESULTS: Silicone oil was successfully removed in all cases. The mean SOR time was 5.70±0.85min. Nine eyes (18.75%) needed suture partial sclerotomies. No intraoperative complications were noted. Transient hypotony (≤8 mm Hg) was seen in 3 eyes (6.25%) on postoperative day 1, but all resolved within 1wk. Retinal reattachment was achieved in all cases and no other postoperative complications were noted during 3-month following-up. BCVA at the final visit improved or stabilized in all patients comparing to the preoperative level. CONCLUSION: Active removal of high viscosity silicone oil through a 23-gauge instrument cannula jointed with blood transfusion set is a practical and reliable technique when considering two sides of efficacy and safety.
AIM: To report a simple approach to actively remove high viscosity silicone oil through a 23-gauge cannula via pars plana. METHODS: Forty-eight eyes of 48 patients underwent silicone oil (5700 centistokes) removal (SOR) were enrolled. A section of blood transfusion set was prepared to connect a standard 23-gauge cannula and vitrectomy machine. Silicone oil was removed with suction of 500-mm Hg vacuum through the cannula. Main outcome measures were SOR duration, number of sutured sites, intraocular pressure (IOP), best-corrected visual acuity (BCVA), and complications. RESULTS:Silicone oil was successfully removed in all cases. The mean SOR time was 5.70±0.85min. Nine eyes (18.75%) needed suture partial sclerotomies. No intraoperative complications were noted. Transient hypotony (≤8 mm Hg) was seen in 3 eyes (6.25%) on postoperative day 1, but all resolved within 1wk. Retinal reattachment was achieved in all cases and no other postoperative complications were noted during 3-month following-up. BCVA at the final visit improved or stabilized in all patients comparing to the preoperative level. CONCLUSION: Active removal of high viscosity silicone oil through a 23-gauge instrument cannula jointed with blood transfusion set is a practical and reliable technique when considering two sides of efficacy and safety.
Entities:
Keywords:
23-gauge; active removal; pars plana; silicone oil
Authors: Omesh P Gupta; Allen C Ho; Peter K Kaiser; Carl D Regillo; Sanford Chen; David S Dyer; Pravin U Dugel; Sunil Gupta; John S Pollack Journal: Am J Ophthalmol Date: 2008-06-10 Impact factor: 5.258