J G Weg1, C F Haas. 1. Division of Pulmonary and Critical Care Medicine, University of Michigan Medical Center, Ann Arbor.
Abstract
STUDY OBJECTIVE: To determine whether manual ventilation during intrahospital transport of mechanically ventilated critically ill patients results in blood gas and/or hemodynamic abnormalities. DESIGN: A single-blind prospective study evaluated arterial blood gas, blood pressure, heart rate, and arrhythmia changes during mechanical ventilation and manual transport ventilation. SETTING: University hospital ICUs and various diagnostic or treatment areas. PATIENTS: Twenty mechanically ventilated critically ill patients during intrahospital transport. INTERVENTION: Each patient received mechanical ventilation (MECH) with a volume ventilator while in the ICU and at the study/treatment area. They were manually ventilated (MAN) by a respiratory therapist during transport between areas. MEASUREMENTS AND MAIN RESULTS: The MECH settings were: VT = 0.75 +/- 0.17 L; f = 16 +/- 4; VE = 12.6 +/- 4.3 L/min; FIO2 = 0.46 +/- 0.2. Mean peak Paw = 31 +/- 12 cm H2O and mean effective Cst = 44 +/- 15 ml/cm H2O. No hemodynamic abnormalities were observed. Arterial blood gas values did not vary to any clinically significant degree, except in two patients: one patient had a reduced PaO2 and increased PaCO2 associated with an accidental O2 disconnection and clamped chest tube; another patient had an increased pH by 0.13 units with only a 9 mm Hg fall in PaCO2. CONCLUSIONS: Manual ventilation during intrahospital transport of critically ill mechanically ventilated patients is safe provided the person performing manual ventilation knows the inspired oxygen fraction and minute ventilation required before transport and is trained to approximate them during transport.
STUDY OBJECTIVE: To determine whether manual ventilation during intrahospital transport of mechanically ventilated critically ill patients results in blood gas and/or hemodynamic abnormalities. DESIGN: A single-blind prospective study evaluated arterial blood gas, blood pressure, heart rate, and arrhythmia changes during mechanical ventilation and manual transport ventilation. SETTING: University hospital ICUs and various diagnostic or treatment areas. PATIENTS: Twenty mechanically ventilated critically ill patients during intrahospital transport. INTERVENTION: Each patient received mechanical ventilation (MECH) with a volume ventilator while in the ICU and at the study/treatment area. They were manually ventilated (MAN) by a respiratory therapist during transport between areas. MEASUREMENTS AND MAIN RESULTS: The MECH settings were: VT = 0.75 +/- 0.17 L; f = 16 +/- 4; VE = 12.6 +/- 4.3 L/min; FIO2 = 0.46 +/- 0.2. Mean peak Paw = 31 +/- 12 cm H2O and mean effective Cst = 44 +/- 15 ml/cm H2O. No hemodynamic abnormalities were observed. Arterial blood gas values did not vary to any clinically significant degree, except in two patients: one patient had a reduced PaO2 and increased PaCO2 associated with an accidental O2 disconnection and clamped chest tube; another patient had an increased pH by 0.13 units with only a 9 mm Hg fall in PaCO2. CONCLUSIONS: Manual ventilation during intrahospital transport of critically ill mechanically ventilated patients is safe provided the person performing manual ventilation knows the inspired oxygen fraction and minute ventilation required before transport and is trained to approximate them during transport.
Authors: Parthak Prodhan; Richard T Fiser; Sophia Cenac; Adnan T Bhutta; Eudice Fontenot; Michelle Moss; Stephen Schexnayder; Paul Seib; Carl Chipman; Lauren Weygandt; Michiaki Imamura; Robert D B Jaquiss; Umesh Dyamenahalli Journal: Pediatr Crit Care Med Date: 2010-03 Impact factor: 3.624
Authors: Ursula Beckmann; Donna M Gillies; Sean M Berenholtz; Albert W Wu; Peter Pronovost Journal: Intensive Care Med Date: 2004-02-26 Impact factor: 17.440
Authors: Hyun Ju Min; Hyung-Jun Kim; Dong Seon Lee; Yun Young Choi; Miae Yoon; Dayoon Lee; Jun Yeun Cho; Jong Sun Park; Young-Jae Cho; Ho Il Yoon; Jae Ho Lee; Choon-Taek Lee; Yeon Joo Lee Journal: PLoS One Date: 2019-03-05 Impact factor: 3.240
Authors: Mustafa Ahmet Afacan; Mehmet Özgür Erdogan; Abdullah Algın; Miraç Kırcı; Sahin Colak Journal: Emerg Med Int Date: 2019-07-25 Impact factor: 1.112
Authors: Ki Hyuk Joo; In Sool Yoo; Jinwoong Lee; Seung Whan Kim; Seung Ryu; Yeon Ho You; Yong Chul Cho; Woon Jun Jeong; Byung Jun Ahn; Sung Uk Cho Journal: Clin Exp Emerg Med Date: 2016-06-30