Literature DB >> 27654126

Reduced field-of-view DWI with robust fat suppression and unrestricted slice coverage using tilted 2D RF excitation.

Suchandrima Banerjee1, Dwight G Nishimura2, Ajit Shankaranarayanan1, Emine Ulku Saritas3,4.   

Abstract

PURPOSE: Reduced field-of-view (rFOV) diffusion-weighted imaging (DWI) using 2D echo-planar radiofrequency (2DRF) excitation has been widely and successfully applied in clinical settings. The purpose of this work is to further improve its clinical utility by overcoming slice coverage limitations without any scan time penalty while providing robust fat suppression. THEORY AND METHODS: During multislice imaging with 2DRF pulses, periodic sidelobes in the slice direction cause partial saturation, limiting the slice coverage. In this work, a tilting of the excitation plane is proposed to push the sidelobes out of the imaging section while preserving robust fat suppression. The 2DRF pulse is designed using Shinnar-Le Roux algorithm on a rotated excitation k-space. The performance of the method is validated via simulations, phantom experiments, and high in-plane resolution in vivo DWI of the spinal cord.
RESULTS: Results show that rFOV DWI using the tilted 2DRF pulse provides increased signal-to-noise ratio, extended coverage, and robust fat suppression, without any scan time penalty.
CONCLUSION: Using a tilted 2DRF excitation, a high-resolution rFOV DWI method with robust fat suppression and unrestricted slice coverage is presented. This method will be beneficial in clinical applications needing large slice coverage, for example, axial imaging of the spine, prostate, or breast. Magn Reson Med 76:1668-1676, 2016.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Keywords:  2D RF pulse; diffusion-weighted imaging; fat suppression; multislice imaging; reduced field-of-view

Mesh:

Year:  2016        PMID: 27654126     DOI: 10.1002/mrm.26405

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  Three-dimensional reduced field-of-view imaging (3D-rFOVI).

Authors:  Kaibao Sun; Zheng Zhong; Guangyu Dan; Muge Karaman; Qingfei Luo; Xiaohong Joe Zhou
Journal:  Magn Reson Med       Date:  2021-12-11       Impact factor: 4.668

2.  MRI with sub-millisecond temporal resolution over a reduced field of view.

Authors:  Zheng Zhong; Kaibao Sun; Guangyu Dan; Qingfei Luo; Xiaohong Joe Zhou
Journal:  Magn Reson Med       Date:  2021-07-16       Impact factor: 4.668

Review 3.  Quantitative imaging biomarkers alliance (QIBA) recommendations for improved precision of DWI and DCE-MRI derived biomarkers in multicenter oncology trials.

Authors:  Amita Shukla-Dave; Nancy A Obuchowski; Thomas L Chenevert; Sachin Jambawalikar; Lawrence H Schwartz; Dariya Malyarenko; Wei Huang; Susan M Noworolski; Robert J Young; Mark S Shiroishi; Harrison Kim; Catherine Coolens; Hendrik Laue; Caroline Chung; Mark Rosen; Michael Boss; Edward F Jackson
Journal:  J Magn Reson Imaging       Date:  2018-11-19       Impact factor: 5.119

4.  Cardiac MR elastography using reduced-FOV, single-shot, spin-echo EPI.

Authors:  Yi Sui; Shivaram P Arunachalam; Arvin Arani; Joshua D Trzasko; Phillip M Young; James F Glockner; Kevin J Glaser; David S Lake; Kiaran P McGee; Armando Manduca; Phillip J Rossman; Richard L Ehman; Philip A Araoz
Journal:  Magn Reson Med       Date:  2017-12-01       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.