Patch Testing for Evaluation of Hypersensitivity to Implanted Metal Devices: A Perspective From the American Contact Dermatitis Society.

Peter C Schalock1, Glen Crawford, Susan Nedorost, Pamela L Scheinman, Amber Reck Atwater, Christen Mowad, Bruce Brod, Alison Ehrlich, Kalman L Watsky, Denis Sasseville, Dianne Silvestri, Sophie M Worobec, John F Elliott, Golara Honari, Douglas L Powell, James Taylor, Joel DeKoven.   

Abstract

The American Contact Dermatitis Society recognizes the interest in the evaluation and management of metal hypersensitivity reactions. Given the paucity of robust evidence with which to guide our practices, we provide reasonable evidence and expert opinion-based guidelines for clinicians with regard to metal hypersensitivity reaction testing and patient management. Routine preoperative evaluation in individuals with no history of adverse cutaneous reactions to metals or history of previous implant-related adverse events is not necessary. Patients with a clear self-reported history of metal reactions should be evaluated by patch testing before device implant. Patch testing is only 1 element in the assessment of causation in those with postimplantation morbidity. Metal exposure from the implanted device can cause sensitization, but a positive metal test does not prove symptom causality. The decision to replace an implanted device must include an assessment of all clinical factors and a thorough risk-benefit analysis by the treating physician(s) and patient.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27649347     DOI: 10.1097/DER.0000000000000210

Source DB:  PubMed          Journal:  Dermatitis        ISSN: 1710-3568            Impact factor:   4.845


  11 in total

1.  Self-reported metal hypersensitivity in patients undergoing unicondylar knee arthroplasty.

Authors:  Halis Atıl Atilla; Hüseyin Bilgehan Çevik; Mutlu Akdoğan; Hakan Aslan
Journal:  J Clin Orthop Trauma       Date:  2020-10-05

Review 2.  Hypersensitivity to Orthopedic Implants: A Review of the Literature.

Authors:  Joseph Wawrzynski; Joseph A Gil; Avi D Goodman; Gregory R Waryasz
Journal:  Rheumatol Ther       Date:  2017-03-31

Review 3.  Metal Hypersensitivity Reactions to Orthopedic Implants.

Authors:  Wendy Z W Teo; Peter C Schalock
Journal:  Dermatol Ther (Heidelb)       Date:  2016-12-19

4.  Exploring the Incidence, Implications, and Relevance of Metal Allergy to Orthopaedic Surgeons.

Authors:  Stefanos F Haddad; Melissa M Helm; Benjamin Meath; Curtis Adams; Nalini Packianathan; Richard Uhl
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2019-04-05

Review 5.  Utility of Patch Testing and Lymphocyte Transformation Testing in the Evaluation of Metal Allergy in Patients with Orthopedic Implants.

Authors:  Logan J Richards; Alexandra Streifel; Jonathan M Rodrigues
Journal:  Cureus       Date:  2019-09-25

Review 6.  Metal allergy after the Nuss procedure for pectus excavatum: a review.

Authors:  Przemysław Gałązka; Kamil Leis; Kacper Kroczek; Aleksandra Baska; Jakub Kazik; Rafał Czajkowski
Journal:  Postepy Dermatol Alergol       Date:  2021-01-06       Impact factor: 1.837

7.  Influence of Psychological Distress in Patients with Hypoallergenic Total Knee Arthroplasty. Treatment Algorithm for Patients with Metal Allergy and Knee Osteoarthritis.

Authors:  Pilar Peña; Miguel A Ortega; Julia Buján; Basilio De la Torre
Journal:  Int J Environ Res Public Health       Date:  2021-06-03       Impact factor: 3.390

Review 8.  Contact dermatitis.

Authors:  Pamela L Scheinman; Marc Vocanson; Jacob P Thyssen; Jeanne Duus Johansen; Rosemary L Nixon; Kate Dear; Nina C Botto; Johanna Morot; Ari M Goldminz
Journal:  Nat Rev Dis Primers       Date:  2021-05-27       Impact factor: 52.329

9.  Is the hip prosthesis responsible for this rash?

Authors:  Caitlyn T Reed; Chelsea S Mockbee; Robert T Brodell; Stephen E Helms
Journal:  JAAD Case Rep       Date:  2017-12-18

10.  Letter to the Editor: Metal hypersensitivity reactions in the context of Essure.

Authors:  Kory Markel; Bruce Brod; Sharon E Jacob
Journal:  Case Rep Womens Health       Date:  2018-10-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.