| Literature DB >> 27649244 |
Yacine Nia1, Mélanie Rodriguez2, Reinhard Zeleny3, Sabine Herbin4, Frédéric Auvray5, Uwe Fiebig6, Marc-André Avondet7, Amalia Munoz8, Jacques-Antoine Hennekinne9.
Abstract
The aim of this work was to organize the first proficiency test (PT) dedicated to staphylococcal enterotoxin B (SEB) detection in milk and buffer solutions. This paper describes the organization of the PT trial according to EN ISO 17043 requirements. Characterization of the SEB stock solution was performed using SDS-PAGE and SE-specific ELISA, and amino acid analysis was used to assign its protein concentration. The solution was then used to prepare six PT materials (four milk and two buffer batches) at a ng/g toxin level, which included one blank and one SEA-containing milk as specificity control. Suitable material homogeneity and stability were assessed using screening and quantitative ELISAs. Among the methods used by the participants, ELISA-based methods demonstrated their efficiency for the detection of SEB in both simple and complex matrices. The results serve as a basis for further improving the detection capabilities in expert laboratories and can therefore be considered as a contribution to biopreparedness.Entities:
Keywords: ELISA methods; bioterrorism agent; proficiency test; staphylococcal enterotoxin B
Mesh:
Substances:
Year: 2016 PMID: 27649244 PMCID: PMC5037494 DOI: 10.3390/toxins8090268
Source DB: PubMed Journal: Toxins (Basel) ISSN: 2072-6651 Impact factor: 4.546
Figure 1SDS-PAGE and silver staining of the SEB solution used for spiking.1: SEB solution (Toxin Technology, Sarasota, FL, USA, Ref BT202 batch number: 91709B); 2: Precision Plus Protein all blue prestained proteins standards (Biorad, Marnes la coquette, France).
Figure 2Homogeneity data obtained for the buffer (B1 and B2) and milk (M2 and M3) samples spiked by SEB. (a): in buffer (B1), (b): in buffer (B2), (c): in milk (M2), (d): in milk (M3).
Figure 3Stability data obtained for the milk and buffer samples spiked by SEB. Data were presented as recovery calculated from the measured SEB concentrations in stability samples and the assigned value corresponding to the homogeneity value.
Evaluation of the ELISA based qualitative results obtained by participating laboratories.
| Lab Code | Method Used | M1 | M2 | M3 | M4 | B1 | B2 | |
|---|---|---|---|---|---|---|---|---|
| 1 | ELISA electrochemical immunosensor—Portable Toxin Detector pTD (Bruker) | |||||||
| 3 | Ridascreen SET ABCDE (Rbiopharm) | |||||||
| In house ELISA | ||||||||
| 4 | Vidas SET2 (Biomerieux) | |||||||
| 5 | Oxoid SET RPLA (Termo Scientific) | |||||||
| 6 | Vidas SET2 (Biomerieux) | |||||||
| Oxoid SET RPLA (Termo Scientific) | ||||||||
| TetraCore ELISA kit (TetraCore) | ||||||||
| 7 | miPROTECT SEB (Miprolab) | |||||||
| 8 | In house ELISA | |||||||
| Western blot | ||||||||
| 9 | In house ELISA [ | extraction without dialysis concentration | ||||||
| extraction with dialysis concentration | ||||||||
| 10 | miPROTECT SEB (Miprolab) | |||||||
| 11 | Vidas SET2 (Biomerieux) | |||||||
| Oxoid SET RPLA (Termo Scientific) | ||||||||
| 12 | Vidas SET2 (Biomerieux) | |||||||
| Tecra SET VIA (3M) | ||||||||
| Ridascreen SET Total (Rbiopharm) | ||||||||
| In house ELISA [ | ||||||||
| 13 | Vidas SET2 (Biomerieux) | |||||||
| Oxoid SET RPLA (Termo Scientific) | ||||||||
| 14 | Ridascreen SET ABCDE (Rbiopharm) | |||||||
| TetraCore ELISA kit (TetraCore) | ||||||||
| In house ELISA | ||||||||
| 16 | Lateral Flow Assay | |||||||
| 17 | In house EIA | |||||||
| In house Immunochromatographic Test SEB | ||||||||
A green box: SEB identified in samples B1 and B2, M2 and M3. For M1, SEB specifically not detected. For M4, SEB not specifically detected, A light green box: SEB detected in B1, B2, M2, and M3 but other serotypes were identified in these samples. For M1 and M4, SEs were not detected without specification of the toxin type, A red box: false positive or false negative results were obtained, A white box: samples were not analyzed.
Evaluation of quantitative results obtained by ELISA-based methods.
| Lab Code | Method Used | M2 | M3 | B1 | B2 | |
|---|---|---|---|---|---|---|
| 1 | ELISA electrochemical immunosensor—Portable Toxin Detector pTD (Bruker) | |||||
| 3 | In house ELISA | |||||
| 7 | miPROTECT SEB (Miprolab) | |||||
| 8 | In house ELISA | |||||
| 9 | In house ELISA [ | extraction without dialysis concentration | ||||
| extraction with dialysis concentration | ||||||
| 12 | In-house-ELISA [ | |||||
| 14 | In-house-ELISA | |||||
| 16 | Lateral Flow Assay | |||||
| 17 | In house EIA | |||||
| 17 | In house Immunochromatographic Test SEB | |||||
Interpretation: : satisfactory results; : questionable results; : unsatisfactory results.
Figure 4Preparation of the SEB samples.