Literature DB >> 27635791

Efficacy of the radial acquisition regime (RADAR) for acquiring head and neck MR images.

Tsukasa Kojima1, Hidetake Yabuuchi1, Hiroshi Narita2, Seiji Kumazawa1, Yuzo Yamasaki3, Yuki Yano1, Noriyuki Sakai1, Yoichi Kurihara4, Kiyoshi Hisada4, Masafumi Masaki4, Hiroshi Kimura5.   

Abstract

OBJECTIVE: To investigate the efficacy of the radial acquisition regime (RADAR) for acquiring head and neck MR images.
METHODS: 15 healthy volunteers underwent imaging with 4 sequences [fast spin echo T2 weighted imaging (FSE-T2WI), RADAR T2 weighted imaging (RADAR-T2WI), single-shot echo planar imaging diffusion-weighted imaging (SS-EPI-DWI) and RADAR diffusion-weighted imaging (RADAR-DWI)]. Both standard images and images during periodic mouth motion were acquired. Two radiologists scored the overall image artefacts and detectability of several anatomical structures without knowledge of sequence type. For each sequence, image distortion was quantitatively compared by the anteroposterior to right-left ratio of several anatomical structures. The mean scores of artefacts and distortion of several anatomical structures were compared using the multiple comparison test. The detectabilities were compared using the Wilcoxon signed-rank test.
RESULTS: Regardless of mouth motion, RADAR-T2WI was significantly superior to FSE-T2WI in artefacts and oral-area detectability (p < 0.01), and RADAR-DWI was significantly superior to SS-EPI-DWI in terms of artefacts (p < 0.01). In terms of image distortion, RADAR-DWI was significantly superior to SS-EPI-DWI (p < 0.01).
CONCLUSION: RADAR-T2WI could replace FSE-T2WI as a conventional T2WI protocol for the head and neck. For the RADAR-DWI sequence, validation studies are needed. Advances in knowledge: RADAR-T2WI was superior to FSE-T2WI with regard to artefacts and detectability, and RADAR-DWI was superior in terms of artefacts compared with SS-EPI-DWI.

Entities:  

Mesh:

Year:  2016        PMID: 27635791      PMCID: PMC5124827          DOI: 10.1259/bjr.20160007

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  18 in total

1.  Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging.

Authors:  J G Pipe
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  PROPELLER MRI: clinical testing of a novel technique for quantification and compensation of head motion.

Authors:  K P Forbes; J G Pipe; C R Bird; J E Heiserman
Journal:  J Magn Reson Imaging       Date:  2001-09       Impact factor: 4.813

3.  Multishot diffusion-weighted FSE using PROPELLER MRI.

Authors:  James G Pipe; Victoria G Farthing; Kirsten P Forbes
Journal:  Magn Reson Med       Date:  2002-01       Impact factor: 4.668

4.  Comparison of brain MR images at 1.5T using BLADE and rectilinear techniques for patients who move during data acquisition.

Authors:  E Nyberg; G S Sandhu; J Jesberger; K A Blackham; D P Hsu; M A Griswold; J L Sunshine
Journal:  AJNR Am J Neuroradiol       Date:  2011-11-17       Impact factor: 3.825

5.  Noise measurement and estimation in MR imaging experiments.

Authors:  Johannes T Heverhagen
Journal:  Radiology       Date:  2007-12       Impact factor: 11.105

6.  Measurement of signal-to-noise ratio in MR imaging with sensitivity encoding.

Authors:  Won-Jin Moon
Journal:  Radiology       Date:  2007-06       Impact factor: 11.105

7.  Anatomic localization and quantitative analysis of gradient refocused echo-planar fMRI susceptibility artifacts.

Authors:  J G Ojemann; E Akbudak; A Z Snyder; R C McKinstry; M E Raichle; T E Conturo
Journal:  Neuroimage       Date:  1997-10       Impact factor: 6.556

8.  The effect of motion on two-dimensional Fourier transformation magnetic resonance images.

Authors:  C L Schultz; R J Alfidi; A D Nelson; S Y Kopiwoda; M E Clampitt
Journal:  Radiology       Date:  1984-07       Impact factor: 11.105

9.  Role of periodically rotated overlapping parallel lines with enhanced reconstruction diffusion-weighted imaging in correcting distortion and evaluating head and neck masses using 3 T MRI.

Authors:  X Chen; J Xian; X Wang; Y Wang; Z Zhang; J Guo; J Li
Journal:  Clin Radiol       Date:  2013-12-17       Impact factor: 2.350

Review 10.  Advances in magnetic resonance neuroimaging techniques in the evaluation of neonatal encephalopathy.

Authors:  Ashok Panigrahy; Stefan Blüml
Journal:  Top Magn Reson Imaging       Date:  2007-02
View more