Literature DB >> 11536397

PROPELLER MRI: clinical testing of a novel technique for quantification and compensation of head motion.

K P Forbes1, J G Pipe, C R Bird, J E Heiserman.   

Abstract

While head motion is considered a significant problem in magnetic resonance imaging (MRI), there is no data to quantify its extent, severity, or effect on image quality. PROPELLER (Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction) MRI offers a novel means of quantifying and compensating for head motion. We performed axial T2-weighted PROPELLER (motion corrected: P-CR; uncorrected: P-UNCR) and conventional MRI (CONV), with equal scan times, in five normal volunteers and 35 clinical subjects. Volunteers were examined lying still and performing two separate head movements (shake "no" and nod "yes") to assess detection and compensation of in-plane motion by PROPELLER MRI. Images were examined by three radiologists for motion artifact and for overall image quality. Head rotation and translation was detected in all subjects during each slice acquisition, with expected changes occurring with volunteer head motion. Motion artifact was less commonly seen on PROPELLER than CONV MR (chi(2) test P < 0.001). PROPELLER was preferred over CONV in all subjects (P < 0.05) and P-CR was judged superior to P-UNCR (P = 0.02). Intracranial pathology was equally or better demonstrated with PROPELLER. PROPELLER MRI offers a means of quantifying head motion, reducing motion artifact, and improving image quality. Copyright 2001 Wiley-Liss, Inc.

Mesh:

Year:  2001        PMID: 11536397     DOI: 10.1002/jmri.1176

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  28 in total

1.  Utility of fat-suppressed FLAIR and subtraction imaging in detecting meningeal abnormalities.

Authors:  Alexander McKinney; Chris Palmer; James Short; Leandro Lucato; Charles Truwit
Journal:  Neuroradiology       Date:  2006-09-13       Impact factor: 2.804

2.  A tractography comparison between turboprop and spin-echo echo-planar diffusion tensor imaging.

Authors:  Minzhi Gui; Huiling Peng; John D Carew; Maciej S Lesniak; Konstantinos Arfanakis
Journal:  Neuroimage       Date:  2008-06-21       Impact factor: 6.556

Review 3.  Pediatric obesity phenotyping by magnetic resonance methods.

Authors:  Wei Shen; Haiying Liu; Mark Punyanitya; Jun Chen; Steven B Heymsfield
Journal:  Curr Opin Clin Nutr Metab Care       Date:  2005-11       Impact factor: 4.294

4.  Improved abdominal MRI in non-breath-holding children using a radial k-space sampling technique.

Authors:  Jong Hyuk Lee; Young Hun Choi; Jung Eun Cheon; So Mi Lee; Hyun Hae Cho; Su Mi Shin; Woo Sun Kim; In One Kim
Journal:  Pediatr Radiol       Date:  2015-01-24

Review 5.  MRI evaluation and safety in the developing brain.

Authors:  Shannon Tocchio; Beth Kline-Fath; Emanuel Kanal; Vincent J Schmithorst; Ashok Panigrahy
Journal:  Semin Perinatol       Date:  2015-03-03       Impact factor: 3.300

Review 6.  Motion artifacts in MRI: A complex problem with many partial solutions.

Authors:  Maxim Zaitsev; Julian Maclaren; Michael Herbst
Journal:  J Magn Reson Imaging       Date:  2015-01-28       Impact factor: 4.813

Review 7.  Magnetic resonance imaging acquisition techniques intended to decrease movement artefact in paediatric brain imaging: a systematic review.

Authors:  Julie Woodfield; Susan Kealey
Journal:  Pediatr Radiol       Date:  2015-03-28

8.  Image quality assessment of silent T2 PROPELLER sequence for brain imaging in infants.

Authors:  Hyun Gi Kim; Jin Wook Choi; Soo Han Yoon; Sieun Lee
Journal:  Br J Radiol       Date:  2017-12-22       Impact factor: 3.039

9.  BLADE in sagittal T2-weighted MR imaging of the cervical spine.

Authors:  C Fellner; C Menzel; F A Fellner; C Ginthoer; N Zorger; A Schreyer; E M Jung; S Feuerbach; T Finkenzeller
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-26       Impact factor: 3.825

Review 10.  Cutting-edge imaging of the spine.

Authors:  A Talia Vertinsky; Michael V Krasnokutsky; Michael Augustin; Roland Bammer
Journal:  Neuroimaging Clin N Am       Date:  2007-02       Impact factor: 2.264

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.