Literature DB >> 27634028

Impact of Angiographic Result After Predilatation on Outcome After Drug-Coated Balloon Treatment of In-Stent Coronary Restenosis.

Akihito Tanaka1, Azeem Latib1, Richard J Jabbour2, Hiroyoshi Kawamoto1, Francesco Giannini3, Marco Ancona3, Damiano Regazzoli3, Antonio Mangieri3, Roberto Mattioli4, Alaide Chieffo3, Mauro Carlino3, Matteo Montorfano3, Antonio Colombo5.   

Abstract

This study investigates clinical outcomes after drug-coated balloon (DCB) treatment for in-stent restenosis (ISR) based on the angiographic result achieved after predilatation and before DCB treatment. Among ISR lesions treated with DCBs, 166 lesions with angiography immediately after predilatation were analyzed. The lesions were divided into 2 groups according to angiographic results after predilatation: (1) "adequate" defined as the presence of Thrombolysis In Myocardial Infarction 3 flow, residual stenosis ≤30%, and no major dissections (n = 98 lesions) or (2) "inadequate" (n = 68 lesions). The reference vessel diameters were larger (2.88 ± 0.39 vs 2.64 ± 0.52 mm, p = 0.001) and lesion lengths shorter in the adequate group (15.4 ± 11.2 vs 19.7 ± 13.9 mm, p = 0.04). During a median follow-up of 808 days, the cumulative target lesion revascularization (TLR) rate was lower in the adequate group (20.3% vs 35.5% at 2 years; p = 0.04). Multivariate analysis indicated that an angiographically inadequate result before DCB treatment was an independent predictor of TLR, even after adjusting for reference vessel diameter and lesion length (hazard ratio 1.99, 95% confidence interval 1.02 to 3.87, p = 0.04). In conclusion, angiographic results after lesion preparation appear to be a good predictor of TLR after DCB treatment for ISR.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27634028     DOI: 10.1016/j.amjcard.2016.08.006

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  3 in total

1.  The effect of the debulking by excimer laser coronary angioplasty on long-term outcome compared with drug-coating balloon: insights from optical frequency domain imaging analysis.

Authors:  Takao Sato; Keiichi Tsuchida; Sho Yuasa; Yuji Taya; Tomoyasu Koshikawa; Komei Tanaka; Satoshi Fujita; Yoshio Ikeda; Minoru Takahashi; Masaaki Okabe; Hirotaka Oda; Yoshifusa Aizawa
Journal:  Lasers Med Sci       Date:  2019-07-01       Impact factor: 3.161

2.  Stentless at ostium: a novel approach for treating ostial left anterior descending or left circumflex coronary artery lesions with drug-coated balloons.

Authors:  Wen-Jie Lu; Liang Pan; Zhan-Ying Han; San-Cong Pan; Xi Wang; Ying-Guang Shan; Meng Peng; Xiao-Fei Qin; Guo-Ju Sun; Pei-Sheng Zhang; Jian-Zeng Dong; Chun-Guang Qiu
Journal:  Am J Transl Res       Date:  2022-09-15       Impact factor: 3.940

Review 3.  Drug-coated Balloons for Small Coronary Disease-A Literature Review.

Authors:  Ketina Arslani; Raban Jeger
Journal:  Curr Cardiol Rep       Date:  2021-10-14       Impact factor: 2.931

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.