| Literature DB >> 27628262 |
Declan G Murphy1,2, John Pedersen3, Anthony J Costello4,5.
Abstract
We report the first case of salvage robotic-assisted laparoscopic radical prostatectomy (RALP) following failed primary high-intensity focussed ultrasound (HIFU) for localised carcinoma of the prostate. A 66-year-old male with a presenting prostate-specific antigen (PSA) of 5 ng/ml was diagnosed with T1c Gleason 3 + 4 prostate cancer. He underwent transurethral resection of the prostate and HIFU. His PSA dropped to 2.0 ng/ml and repeat biopsy revealed upgrading of his prostate cancer to Gleason 4 + 3. He was referred to us for a second opinion and, following discussion of his options, he underwent RALP. The total operative time was 159 min. There were no intra- or postoperative complications. He was discharged on postoperative day two and was fully continent 10 days following removal of his catheter. His PSA remained undetectable 6 months postoperatively. Salvage RALP was feasible in this case with good functional and short-term oncological outcomes for the patient.Entities:
Keywords: HIFU; High-intensity focussed ultrasound; Laparoscopic; Prostate cancer; Radical prostatectomy; Robotic; Salvage; da Vinci
Year: 2008 PMID: 27628262 DOI: 10.1007/s11701-008-0097-3
Source DB: PubMed Journal: J Robot Surg ISSN: 1863-2483