Literature DB >> 27627940

Coronary stent technology: a narrative review.

Daniel Chen1, Nigel Jepson2.   

Abstract

Coronary angioplasty and coronary artery stents have revolutionised interventional cardiology. Contemporary coronary stent technology continues to seek to improve on the outcomes of the preceding generation of devices by refining their design, structure and component materials. These technologies include new generations of drug-eluting stents, non-polymeric stents, bioresorbable polymer-coated stents, and fully bioresorbable scaffolds. This review discusses the evolution of coronary stent technology, the efficacy and safety of currently available devices, and the rationale for new generation platforms as efforts continue to design the ideal coronary stent technology.

Entities:  

Mesh:

Year:  2016        PMID: 27627940     DOI: 10.5694/mja16.00444

Source DB:  PubMed          Journal:  Med J Aust        ISSN: 0025-729X            Impact factor:   7.738


  7 in total

Review 1.  Evolutionary perspective of drug eluting stents: from thick polymer to polymer free approach.

Authors:  Sadia Hassan; Murtaza Najabat Ali; Bakhtawar Ghafoor
Journal:  J Cardiothorac Surg       Date:  2022-04-04       Impact factor: 1.637

Review 2.  Recent advances in targeted delivery of non-coding RNA-based therapeutics for atherosclerosis.

Authors:  Xiaoxin Li; Hongzhao Qi; Weigang Cui; Zhibin Wang; Xiuxiu Fu; Tianxiang Li; Huibo Ma; Yanyan Yang; Tao Yu
Journal:  Mol Ther       Date:  2022-08-01       Impact factor: 12.910

Review 3.  Engineering biomaterials to prevent post-operative infection and fibrosis.

Authors:  Aditya Josyula; Kunal S Parikh; Ian Pitha; Laura M Ensign
Journal:  Drug Deliv Transl Res       Date:  2021-03-12       Impact factor: 5.671

4.  Long-term (2-5 years) adverse clinical outcomes associated with ZES versus SES, PES and EES: A Meta-Analysis.

Authors:  Pravesh Kumar Bundhun; Akash Bhurtu; Manish Pursun; Mohammad Zafooruddin Sani Soogund; Abhishek Rishikesh Teeluck; Wei-Qiang Huang
Journal:  Sci Rep       Date:  2017-07-25       Impact factor: 4.379

5.  Biodegradable polymer versus second-generation durable polymer drug-eluting stents in patients with coronary artery disease: A meta-analysis.

Authors:  James J Wu; Joshua A H Way; Probal Roy; Andy Yong; Harry Lowe; Leonard Kritharides; David Brieger
Journal:  Health Sci Rep       Date:  2018-10-05

Review 6.  Polymer-free versus durable polymer drug-eluting stents in patients with coronary artery disease: A meta-analysis.

Authors:  James J Wu; Joshua A H Way; Leonard Kritharides; David Brieger
Journal:  Ann Med Surg (Lond)       Date:  2018-12-11

Review 7.  Drug-Eluting Stents and Balloons-Materials, Structure Designs, and Coating Techniques: A Review.

Authors:  I Rykowska; I Nowak; R Nowak
Journal:  Molecules       Date:  2020-10-11       Impact factor: 4.411

  7 in total