Literature DB >> 27623731

Hepatocyte Concentrations of Indocyanine Green Reflect Transfer Rates Across Membrane Transporters.

Fabien Cusin1, Liliana Fernandes Azevedo1, Pierre Bonnaventure1, Jules Desmeules2, Youssef Daali2, Catherine M Pastor1,3,4.   

Abstract

Perioperative imaging with indocyanine green (ICG) is developing to increase safety in dissecting anatomical structures during hepatobiliary surgery. Images obtained with the fluorescence camera rely on concentrations measured in liver regions of interest. However, how ICG sinusoidal uptake and hepatocyte elimination rates generate ICG hepatocyte concentrations is largely unknown. To investigate such issue and better understand the role of membrane transporters in generating ICG hepatocyte concentrations, we perfused ICG in livers isolated from normal livers. Whether the well-known transporter inhibitor rifampicin modifies hepatocyte ICG concentrations was also studied. The dye has a very high and constant extraction ratio (96%) into hepatocytes. This persistent high extraction ratio generates a huge uphill concentration gradient across the sinusoidal membrane: from 5 μM (sinusoids) to 1600 μM (liver). When inside hepatocytes, ICG has low hepatocyte elimination (7 nmol/min.) and liver concentrations do not decrease much over time. Moreover, the tiny hepatocyte ICG efflux is mainly due to ICG return back to sinusoids (90%). Rifampicin slightly inhibits ICG uptake into hepatocytes and when inside hepatocytes blocks ICG efflux into bile canaliculi. In contrast, it increases ICG efflux back to sinusoids with significant decrease in ICG liver concentrations. Imaging with ICG in the perioperative period reflects the high hepatocyte concentrations and relies on the high extraction ratio across hepatocyte sinusoidal membrane. Although ICG concentrations are low in bile ducts, they are adequate for a good visualization and avoid bile duct injury.
© 2016 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27623731     DOI: 10.1111/bcpt.12671

Source DB:  PubMed          Journal:  Basic Clin Pharmacol Toxicol        ISSN: 1742-7835            Impact factor:   4.080


  10 in total

1.  Differentiation of Human Parthenogenetic Embryonic Stem Cells into Functional Hepatocyte-like Cells.

Authors:  Rui Liang; Zhiqiang Wang; Xiangyang Kong; Xiaoxiao Xiao; Tianxing Chen; Hui Yang; Ying Li; Xingqi Zhao
Journal:  Organogenesis       Date:  2020-11-25       Impact factor: 2.500

2.  Development of a Human Photoacoustic Imaging Reporter Gene Using the Clinical Dye Indocyanine Green.

Authors:  Nivin N Nyström; Lawrence C M Yip; Jeffrey J L Carson; Timothy J Scholl; John A Ronald
Journal:  Radiol Imaging Cancer       Date:  2019-11-29

3.  A Biliary Tract-Specific Near-Infrared Fluorescent Dye for Image-Guided Hepatobiliary Surgery.

Authors:  Michael P Luciano; Jung-Man Namgoong; Roger R Nani; So-Hyun Nam; Choonghee Lee; Il Hyung Shin; Martin J Schnermann; Jaepyeong Cha
Journal:  Mol Pharm       Date:  2019-06-21       Impact factor: 4.939

4.  Ligation Method to Specifically Label a Liver Segment With Indocyanine Green in an Orthotopic Nude-Mouse Liver-Metastasis Model.

Authors:  Hiroto Nishino; Hannah M Hollandsworth; Yoshihiko Tashiro; Jun Yamamoto; Siamak Amirfakhri; Filemoni Filemoni; Norihiko Sugisawa; Robert M Hoffman; Michael Bouvet
Journal:  In Vivo       Date:  2020 Nov-Dec       Impact factor: 2.155

5.  A Novel Color-Coded Liver Metastasis Mouse Model to Distinguish Tumor and Adjacent Liver Segment.

Authors:  Hiroto Nishino; Hannah M Hollandsworth; Siamak Amirfakhri; Yoshihiko Tashiro; Jun Yamamoto; Michael A Turner; Thinzar M Lwin; Bernhard B Singer; Robert M Hoffman; Michael Bouvet
Journal:  J Surg Res       Date:  2021-04-10       Impact factor: 2.417

6.  Isolated Perfused Rat Livers to Quantify the Pharmacokinetics and Concentrations of Gd-BOPTA.

Authors:  Catherine M Pastor
Journal:  Contrast Media Mol Imaging       Date:  2018-07-11       Impact factor: 3.161

7.  A Percutaneous Portal Vein Puncture Under Artificial Ascites for Intraoperative Hepatic Segmentation Using Indocyanine Green Fluorescence: A Technical Report of Laparoscopic Anatomic Liver Resection.

Authors:  Meidai Kasai; Tukasa Aihara; Shinichi Ikuta; Takayoshi Nakajima; Naoki Yamanaka
Journal:  Surg Laparosc Endosc Percutan Tech       Date:  2021-12-09       Impact factor: 1.719

8.  Functionalization of theranostic AGuIX® nanoparticles for PET/MRI/optical imaging.

Authors:  Vivek Thakare; Vu-Long Tran; Marco Natuzzi; Eloïse Thomas; Mathieu Moreau; Anthony Romieu; Bertrand Collin; Alan Courteau; Jean-Marc Vrigneaud; Cédric Louis; Stéphane Roux; Frédéric Boschetti; Olivier Tillement; François Lux; Franck Denat
Journal:  RSC Adv       Date:  2019-08-09       Impact factor: 4.036

Review 9.  Dual-Labelling Strategies for Nuclear and Fluorescence Molecular Imaging: Current Status and Future Perspectives.

Authors:  Manja Kubeil; Irma Ivette Santana Martínez; Michael Bachmann; Klaus Kopka; Kellie L Tuck; Holger Stephan
Journal:  Pharmaceuticals (Basel)       Date:  2022-03-31

10.  Hepatobiliary MRI: Signal intensity based assessment of liver function correlated to 13C-Methacetin breath test.

Authors:  Michael Haimerl; Ute Probst; Stefanie Poelsterl; Lukas Beyer; Claudia Fellner; Michael Selgrad; Matthias Hornung; Christian Stroszczynski; Philipp Wiggermann
Journal:  Sci Rep       Date:  2018-06-13       Impact factor: 4.379

  10 in total