Literature DB >> 27623579

A GPU-Parallelized Eigen-Based Clutter Filter Framework for Ultrasound Color Flow Imaging.

Adrian J Y Chee, Billy Y S Yiu, Alfred C H Yu.   

Abstract

Eigen-filters with attenuation response adapted to clutter statistics in color flow imaging (CFI) have shown improved flow detection sensitivity in the presence of tissue motion. Nevertheless, its practical adoption in clinical use is not straightforward due to the high computational cost for solving eigendecompositions. Here, we provide a pedagogical description of how a real-time computing framework for eigen-based clutter filtering can be developed through a single-instruction, multiple data (SIMD) computing approach that can be implemented on a graphical processing unit (GPU). Emphasis is placed on the single-ensemble-based eigen-filtering approach (Hankel singular value decomposition), since it is algorithmically compatible with GPU-based SIMD computing. The key algebraic principles and the corresponding SIMD algorithm are explained, and annotations on how such algorithm can be rationally implemented on the GPU are presented. Real-time efficacy of our framework was experimentally investigated on a single GPU device (GTX Titan X), and the computing throughput for varying scan depths and slow-time ensemble lengths was studied. Using our eigen-processing framework, real-time video-range throughput (24 frames/s) can be attained for CFI frames with full view in azimuth direction (128 scanlines), up to a scan depth of 5 cm ( λ pixel axial spacing) for slow-time ensemble length of 16 samples. The corresponding CFI image frames, with respect to the ones derived from non-adaptive polynomial regression clutter filtering, yielded enhanced flow detection sensitivity in vivo, as demonstrated in a carotid imaging case example. These findings indicate that the GPU-enabled eigen-based clutter filtering can improve CFI flow detection performance in real time.

Year:  2016        PMID: 27623579     DOI: 10.1109/TUFFC.2016.2606598

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  5 in total

1.  Real time SVD-based clutter filtering using randomized singular value decomposition and spatial downsampling for micro-vessel imaging on a Verasonics ultrasound system.

Authors:  U-Wai Lok; Pengfei Song; Joshua D Trzasko; Ron Daigle; Eric A Borisch; Chengwu Huang; Ping Gong; Shanshan Tang; Wenwu Ling; Shigao Chen
Journal:  Ultrasonics       Date:  2020-04-25       Impact factor: 2.890

2.  Deep Learning of Spatiotemporal Filtering for Fast Super-Resolution Ultrasound Imaging.

Authors:  Katherine G Brown; Debabrata Ghosh; Kenneth Hoyt
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-04-15       Impact factor: 2.725

3.  Ultrasound Open Platforms for Next-Generation Imaging Technique Development.

Authors:  Enrico Boni; Alfred C H Yu; Steven Freear; Jorgen Arendt Jensen; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07       Impact factor: 2.725

4.  A Real-Time, GPU-Based Implementation of Aperture Domain Model Image REconstruction.

Authors:  Christopher Khan; Kazuyuki Dei; Siegfried Schlunk; Kathryn Ozgun; Brett Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-05-25       Impact factor: 3.267

5.  High frame rate doppler ultrasound bandwidth imaging for flow instability mapping.

Authors:  Billy Y S Yiu; Adrian J Y Chee; Guo Tang; Wenbo Luo; Alfred C H Yu
Journal:  Med Phys       Date:  2019-03-04       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.