Literature DB >> 27615425

Biomechanical analysis of immediately loaded implants according to the "All-on-Four" concept.

Satoshi Horita1, Tsutomu Sugiura2, Kazuhiko Yamamoto2, Kazuhiro Murakami2, Yuichiro Imai2, Tadaaki Kirita2.   

Abstract

PURPOSE: The purpose of this study was to investigate the biomechanical behavior of immediately loaded implants in an edentulous mandible according to the "All-on-Four" concept.
METHODS: A 3D-finite element model of an edentulous mandible was constructed. Four implants were placed between the bilateral mental foramen according to "All-on-Four" concept. A framework made of titanium or acrylic resin between the bilateral first molars was modeled. Immediate loading and a delayed loading protocol were simulated. A vertical load of 200N was applied at the cantilever or on the abutments region of the distal implants, simulating the absence of a cantilever.
RESULTS: The peak principal compressive strains in the immediate loading models resulted in 24.0-35.8% and 26.4-39.0% increases compared with the delayed loading models under non-cantilever loading and cantilever loading, respectively. The loading position greatly affected the principal compressive and tensile strain values. The peak principal compressive strains in non-cantilever loading resulted in a 45.3-52.6% reduction compared with those in cantilever loading. The framework material did not influence the peak compressive and tensile strain. The maximum micromotion at the bone-implant interface in the immediate loading models was 7.5-14.4μm.
CONCLUSIONS: Mandibular fixed full-arch prostheses without cantilevers may result in a favorable reduction of the peri-implant bone strain during the healing period, compared with cantilevers. The maximum micromotion was within the acceptable limits for uneventful implant osseointegration in the immediate loading models. Framework material did not play an important role in reducing the peri-implant bone strain and micromotion at the bone-implant interface.
Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

Keywords:  All-on-Four concept; Cantilever loading; Finite element analysis; Framework material; Immediate loading

Mesh:

Substances:

Year:  2016        PMID: 27615425     DOI: 10.1016/j.jpor.2016.08.002

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  7 in total

1.  Mechanical analysis of prosthetic bars and dental implants in 3 and 4 implant-supported overdenture protocols using finite element analysis.

Authors:  Luiz Bassi-Junior; Rafael Oliveira de Souza Silva; Victor Hugo Dias Dos Santos; Abner da Rocha Lourenço; Paulo Vinicius Trevizoli; Hugo Gaêta-Araujo; Polyane Mazucatto Queiroz; Vilmar Divanir Gottardo
Journal:  J Oral Biol Craniofac Res       Date:  2021-05-15

2.  Stresses induced by one piece and two piece dental implants in All-on-4® implant supported prosthesis under simulated lateral occlusal loading: non linear finite element analysis study.

Authors:  Ahmed Mostafa Abdelfattah Mohamed; Mohamed Gamal Askar; Mahmoud El-Moutassim Bellah El Homossany
Journal:  BMC Oral Health       Date:  2022-05-22       Impact factor: 3.747

3.  Finite element analysis of the effect of framework materials at the bone-implant interface in the all-on-four implant system.

Authors:  Kasturi Chandrashekhar Kelkar; Vinaya Bhat; Chethan Hegde
Journal:  Dent Res J (Isfahan)       Date:  2021-02-23

4.  Biomechanical properties of the bone during implant placement.

Authors:  Ádám László Nagy; Zsolt Tóth; Tamás Tarjányi; Nándor Tamás Práger; Zoltán Lajos Baráth
Journal:  BMC Oral Health       Date:  2021-02-25       Impact factor: 2.757

5.  Analytical Modeling of the Interaction of a Four Implant-Supported Overdenture with Bone Tissue.

Authors:  Bohdan Pelekhan; Maciej Dutkiewicz; Ivan Shatskyi; Andrii Velychkovych; Mykola Rozhko; Liubomyr Pelekhan
Journal:  Materials (Basel)       Date:  2022-03-24       Impact factor: 3.623

6.  Effects of implant tilting and the loading direction on the displacement and micromotion of immediately loaded implants: an in vitro experiment and finite element analysis.

Authors:  Tsutomu Sugiura; Kazuhiko Yamamoto; Satoshi Horita; Kazuhiro Murakami; Sadami Tsutsumi; Tadaaki Kirita
Journal:  J Periodontal Implant Sci       Date:  2017-08-28       Impact factor: 2.614

7.  Influence of Framework Material and Posterior Implant Angulation in Full-Arch All-on-4 Implant-Supported Prosthesis Stress Concentration.

Authors:  João Paulo Mendes Tribst; Dayana Campanelli de Morais; Jefferson David Melo de Matos; Guilherme da Rocha Scalzer Lopes; Amanda Maria de Oliveira Dal Piva; Alexandre Luiz Souto Borges; Marco Antonio Bottino; Antonio Lanzotti; Massimo Martorelli; Pietro Ausiello
Journal:  Dent J (Basel)       Date:  2022-01-14
  7 in total